UK-wide · Free site survey and fixed written quote for new doors · Repair and service visits priced before we attend

Call 0800 088 6248

Automatic Door Installers

Automatic sliding doors · England

Automatic sliding doors in Lancashire

Replacing a worn manual door with a powered sliding entrance is one of the most common jobs we arrange in Lancashire. The new door is made to your measured opening, fitted with sensors and a programme switch, and handed over with a test record and risk assessment for your files.

Area
Lancashire
Nation
England
Towns listed
21
Guide price
Typically £4,495 to £12,995 ex VAT
  • Free site survey for new doors
  • Fixed, itemised written quote
  • Set up with reference to BS EN 16005
  • England, Wales, Scotland and NI
  • Guide prices published

Coverage across Lancashire

Enquiries about automatic sliding doors come to us from right across Lancashire, and each one is handled the same way. Specialist automatic door engineers working under our management travel to the address, and we remain your contracting party throughout. The 21 towns we list below are a starting point, not a boundary: villages, business parks and rural sites in between are covered as well.

Towns listed in Lancashire: Preston, Burnley, Blackburn, Blackpool, Morecambe, Lancaster, Lytham St Annes, Skelmersdale, Bamber Bridge, Leyland, Accrington, Chorley, Darwen, Thornton-Cleveleys, Nelson, Fleetwood, Ormskirk, Rawtenstall, Colne, Poulton-le-Fylde, Heysham.

What to think about for automatic sliding doors in Lancashire

  • High street entrances with heavy footfall tend to suit bi-parting leaves. They open faster than a single slide for the same clear width, which keeps queues moving at lunchtime and on Saturday afternoons.
  • A sloping pavement or uneven threshold in front of a door in Lancashire can stop floor guides working properly. The survey records floor levels, so any levelling is included in the quote rather than discovered on the day.
  • Entrances in Lancashire that sit on an escape route need the fire strategy checked before the door is designed, because that decides whether break-out leaves, alarm-linked opening or battery opening are required.
  • Older shopfronts in Lancashire often have a timber or steel frame that was never designed to carry a sliding door header. The survey checks what sits above the opening and whether new support is needed before anything is ordered.
  • Surgeries and clinics need wide, easy access for wheelchairs, walking frames and the occasional stretcher. A clear opening of at least 1,000 mm is, in our view, a sensible starting point, and wider still where trolleys or beds pass through.

Automatic sliding doors in Lancashire: guide prices

The site survey is free, including the measured drawing and a fixed, itemised written quote. Guide price: typically £4,495 to £12,995 ex VAT.

ItemGuide priceNotes
Single-slide door set, about 1.0 to 1.2 m clear opening£4,495 – £7,995framed aluminium and glass, installed, ex VAT
Bi-parting door set, about 2 m clear opening, with side screens£6,995 – £12,995installed, ex VAT
Large, full-height or heavy-duty entrancesfrom £14,995Priced on survey
Break-out leaves and screens for an escape route£995 – £3,995added to a sliding door, ex VAT
Touch-free switch or push pad, fitted£145 – £395per switch, ex VAT
Card or fob reader tied into the door£795 – £2,495per door, ex VAT
Battery backup for power-cut operation£395 – £695per door, ex VAT

Standards and rules in England

Building regulations guidance in England (Approved Document M, Volume 2) says a powered opening system should be used where a self-closing entrance door would need more than 30 N at the leading edge to open, or more than 22.5 N between 30° and 60°, and expects external doors used by the public in new buildings to give at least 1000 mm of effective clear width.

In Great Britain a new or converted powered door must meet the Supply of Machinery (Safety) Regulations 2008 before it is first used, and can carry the UKCA or the CE marking. Workplace law (the Workplace (Health, Safety and Welfare) Regulations 1992) expects powered doors to have suitable and effective features to stop them trapping anyone and, where needed for safety, to open by hand unless they open automatically if the power fails. Doors at work must also be kept in efficient working order under a suitable system of maintenance.

Under the Equality Act 2010, service providers and employers must make reasonable adjustments for disabled people, which can include altering a physical feature such as a heavy entrance door. New entrances and some alterations count as building work, so check with building control before the work is ordered.

How it works

  1. Start with a short enquiry. Use the form, phone or email. Tell us whether the work is a new door, an upgrade or an opener for a home, and we arrange the next step for your site in Lancashire.
  2. Measured survey. The free survey confirms what will fit and what the entrance needs: opening width, door type, activation, safety sensors and behaviour on power loss or fire alarm, matched to how the building is used.
  3. Written price, no surprises. A fixed, itemised quote sets out the specification, the work involved, the expected lead time and the warranty terms. You can ask questions or change the specification before accepting it.
  4. Installed and commissioned. The door is installed with as little disruption as possible, then set up and tested for its hazard zones. Before leaving, the engineer explains the controls and hands over the documents for your records.

Get in touch about automatic sliding doors for your premises in Lancashire. The survey is free, the quote is fixed and you are under no obligation to go ahead.

Automatic sliding doors in Lancashire: questions

What happens after the sliding door in Lancashire is fitted?

You get a handover pack with the test record, risk assessment and user instructions, and staff are shown the programme switch. From then on the door needs daily checks and planned servicing. We can quote a service arrangement at intervals based on how much the door is used and the risk.

What is the guide price for automatic sliding doors in Lancashire?

Our guide is £4,495 to £12,995 excluding VAT (per door set), the same guide prices we use across the UK. The free site survey in Lancashire confirms the price as a fixed, itemised written quote, and the guide price tool gives you a range before anyone visits.

Can the old door in Lancashire be removed and taken away?

Yes. Removal of the existing door and frame is listed as a line in the quote, along with making good around the opening. Glass and aluminium are taken away for recycling where possible. If the old door belongs to a landlord, tell us at survey so its removal can be agreed with them before the work is booked.

Will a new sliding door in Lancashire work with our alarm and access control?

In most cases, yes. The operator can take signals from a fire alarm panel, a card reader, a keypad, an intercom or a timer. Tell us what you have at the survey, and the quote will show the interface work and who is responsible for each connection, whether that is us, your electrician or your alarm company.

How do you make sure the door works for disabled visitors in Lancashire?

We look at who uses the entrance: wheelchair users, people with walking aids, parents with buggies and older visitors. That shapes the opening width, the opening speed, the hold-open time and where push pads or sensors go. Service providers and employers have duties to make reasonable adjustments under equality and accessibility law, and an automatic door is a common one.

What does the free site survey in Lancashire involve?

An engineer working under our management visits the building, measures the opening, checks the frame, floor, head height and power supply, and looks at how people use the entrance. The survey is free and carries no obligation. Afterwards you receive a fixed, itemised written quote for automatic sliding doors, with drawings where the door type needs them.

Who is responsible for automatic doors on escape routes in Lancashire?

Under the Regulatory Reform (Fire Safety) Order 2005 the responsible person for the premises must make sure escape routes work and fire safety equipment is maintained. Automatic doors on an escape route need fail-safe opening or break-out, set by the fire strategy.

Next step

Automatic sliding doors in Lancashire

Send the address, a photo if you have one and what the door needs to do. New installations get a free site survey and a fixed written quote; repairs and servicing are priced in writing before we attend.