Covering Bordon and nearby
Our coverage of Bordon takes in the GU35 postcode district and the neighbouring parts of Hampshire. If your address sits close to a boundary, it is still covered: send the postcode with your enquiry about fire door hold-open devices and we will confirm the arrangements and the price in writing.
Independent businesses in Bordon often have one entrance and cannot close for long. Work is usually scheduled early, late or on a quiet day, and where a door must be out of use for a period, we plan to keep the entrance usable or secure.
Nearby towns we also list for fire door hold-open devices (straight-line distance): Alton (5.5 miles), Haslemere (6.9 miles), Farnham (7.5 miles), Aldershot (10.2 miles), Fleet (11.8 miles), Godalming (11.8 miles).
What to think about for fire door hold-open devices in Bordon
- Doors that open too far from a wall for a wall magnet can use a floor-mounted unit or a magnet on an extension arm. The survey measures where each door rests when open.
- Hard-wired magnets need a power supply near each door. In buildings in Bordon where that is awkward, battery units avoid running new cables along finished corridors.
- Older buildings in Bordon may have fire doors that no longer close fully on their own. A hold-open device cannot fix that, so the survey checks closers, hinges and latches first.
- Residential blocks often have communal corridor doors that residents prop open. Hold-open devices give the same convenience while letting the doors close when the alarm sounds.
- Schools and colleges in Bordon may want hold-open devices fitted during the holidays so corridors are not disrupted in term time. Fitting can be planned around term dates.
Fire door hold-open devices in Bordon: guide prices
The site survey is free, including the measured drawing and a fixed, itemised written quote. Guide price: from £145 ex VAT.
| Item | Guide price | Notes |
|---|---|---|
| Battery acoustic hold-open unit | £145 – £295 | per door, fitted, ex VAT |
| Hard-wired hold-open magnet linked to the fire alarm | £245 – £595 | per door, ex VAT; alarm panel work extra |
| Free-swing door closer linked to the fire alarm | £395 – £895 | per door, fitted, ex VAT |
Which hold-open device is suitable depends on your fire risk assessment. Linking to the fire alarm may need work by your alarm engineer.
Standards and rules in England
Fire doors that are held open must close automatically when the fire alarm operates. Where hold-open devices can be used is decided by the fire risk assessment, which is the job of the responsible person under the Regulatory Reform (Fire Safety) Order 2005.
Hold-open devices and door release units linked to the fire alarm need regular testing as part of the building’s fire safety checks, and the results should be recorded.
How it works
- Get in touch. Call, email or use the form with the address and what you have in mind. If you are not sure which type of door suits, describe the entrance and we will suggest the options worth considering.
- Survey and advice. The survey costs nothing and carries no obligation. The engineer checks the site and explains which options suit the entrance, the people using it and the budget, before anything is priced.
- Quote in writing. You receive a fixed, itemised quote for fire door hold-open devices in Bordon, covering equipment, installation, testing and handover, with the lead time and payment stages set out clearly.
- Install, test, explain. The engineer installs and commissions the door, tests the sensors, safety functions and emergency behaviour, and walks you through the controls. The handover pack records what was installed and tested.
Ready to stop wedging fire doors open in Bordon? Book a free survey and get a fixed, itemised quote for every door that needs a hold-open device.
Fire door hold-open devices in Bordon: questions
What will the survey in Bordon look at?
The engineer checks that each door closes and latches from fully open, the condition of the closer and seals, where the door rests when open, nearby power supplies and the alarm panel or radio options. We also ask to see the relevant part of the fire risk assessment, so the quote covers only doors that can be held open.
What will fire door hold-open devices in Bordon cost?
Our guide starts from £145 excluding VAT (per door), the same guide price we use across the UK. The free site survey in Bordon confirms the price as a fixed, itemised written quote, and the guide price tool gives you a range before anyone visits.
Can you work with the fire alarm company that maintains our system in Bordon?
Yes, and for wired devices we usually need to. The connection at the alarm panel is made by, or agreed with, the engineer who looks after your alarm. We share the device details with them and agree the visits, so the alarm and the doors can be tested together once the work is finished.
Do care homes in Bordon use free-swing closers?
Many do. A free-swing closer lets residents open their bedroom door without pushing against a closer, and it still shuts the door when the fire alarm operates. Whether it suits each room depends on the home's fire risk assessment and evacuation strategy, which we read before recommending any device.
Do you service doors in Bordon after installing them?
Yes. We recommend a trained engineer checks the safety functions at least once a year, with service intervals set by the manufacturer's instructions and how heavily the door is used; busy doors are often serviced more often. Servicing can follow on from the installation, with the price agreed in writing and a record left after every visit.
Will the building stay secure while the entrance is being changed?
We plan to keep the entrance usable or secure throughout. Where a door has to come out, the work is sequenced so the opening is closed up before the engineer leaves, or a temporary door or hoarding is arranged when a longer gap cannot be avoided. How this is handled for your site in Bordon is agreed before work starts.
Which building regulations apply to a new automatic entrance in Bordon?
In England the guidance is Approved Document M (Volume 2) for access, Approved Document B for fire safety and escape routes, and Approved Document K for glazing and powered doors. A new entrance can count as building work, so building control should be involved before it is ordered.