Covering Haslemere and nearby
Addresses anywhere in the GU27 postcode district can book fire door hold-open devices through us. The engineer who attends works under our management and travels to the site. There is no branch in Haslemere, so the price, the booking and the paperwork all come from one place.
Older shopfronts are common in market towns, and some in Haslemere may sit in a conservation area or a listed building. Changes to a frontage can need planning permission or listed building consent, so it is worth checking with the local planning authority before work is booked.
Nearby towns we also list for fire door hold-open devices (straight-line distance): Bordon (6.9 miles), Godalming (7.7 miles), Farnham (9.5 miles), Aldershot (11.2 miles), Guildford (11.6 miles), Alton (12.3 miles).
What to think about for fire door hold-open devices in Haslemere
- Background noise matters for acoustic units. Kitchens, plant areas and busy receptions may be too loud for a unit that listens for the alarm, so a wired or radio device is often better there.
- Schools and colleges in Haslemere may want hold-open devices fitted during the holidays so corridors are not disrupted in term time. Fitting can be planned around term dates.
- If the alarm panel has no spare outputs, a relay or an extra interface may be needed. Your alarm engineer can confirm this, and it is added to the quote once agreed.
- Care homes in Haslemere usually want bedroom doors that residents can open easily. Free-swing closers suit this, provided the evacuation strategy for the home supports them.
- Doors that open too far from a wall for a wall magnet can use a floor-mounted unit or a magnet on an extension arm. The survey measures where each door rests when open.
Fire door hold-open devices in Haslemere: guide prices
The site survey is free, including the measured drawing and a fixed, itemised written quote. Guide price: from £145 ex VAT.
| Item | Guide price | Notes |
|---|---|---|
| Battery acoustic hold-open unit | £145 – £295 | per door, fitted, ex VAT |
| Hard-wired hold-open magnet linked to the fire alarm | £245 – £595 | per door, ex VAT; alarm panel work extra |
| Free-swing door closer linked to the fire alarm | £395 – £895 | per door, fitted, ex VAT |
Which hold-open device is suitable depends on your fire risk assessment. Linking to the fire alarm may need work by your alarm engineer.
Standards and rules in England
Fire doors that are held open must close automatically when the fire alarm operates. Where hold-open devices can be used is decided by the fire risk assessment, which is the job of the responsible person under the Regulatory Reform (Fire Safety) Order 2005.
Workplace law (the Workplace (Health, Safety and Welfare) Regulations 1992) expects powered doors to have suitable and effective features to stop them trapping anyone and, where needed for safety, to open by hand unless they open automatically if the power fails. Doors at work must also be kept in efficient working order under a suitable system of maintenance.
How it works
- Start with a short enquiry. Use the form, phone or email. Tell us whether the work is a new door, an upgrade or an opener for a home, and we arrange the next step for your site in Haslemere.
- Measured survey. The free survey confirms what will fit and what the entrance needs: opening width, door type, activation, safety sensors and behaviour on power loss or fire alarm, matched to how the building is used.
- Written price, no surprises. A fixed, itemised quote sets out the specification, the work involved, the expected lead time and the warranty terms. You can ask questions or change the specification before accepting it.
- Installed and commissioned. The door is installed with as little disruption as possible, then set up and tested for its hazard zones. Before leaving, the engineer explains the controls and hands over the documents for your records.
Send us a list of the doors you want held open at your building in Haslemere, plus any notes from your fire risk assessment, and we will arrange a survey at no cost.
Fire door hold-open devices in Haslemere: questions
Will you test the hold-open devices before leaving our site in Haslemere?
Yes. Every door is released from fully open and checked to close and latch. Where the alarm connection is complete, the doors are also tested with the alarm itself. You receive a schedule of the doors and devices fitted, ready to keep with your fire safety records and weekly alarm test log.
What is the guide price for fire door hold-open devices in Haslemere?
Our guide starts from £145 excluding VAT (per door), the same guide price we use across the UK. The free site survey in Haslemere confirms the price as a fixed, itemised written quote, and the guide price tool gives you a range before anyone visits.
Do you fit fire door hold-open devices in Haslemere?
Yes. We arrange surveys and installations in Haslemere through specialist engineers working under our management. They look at each door, its closer and the alarm system, recommend a device for each door and we send a fixed, itemised quote. The survey costs you nothing, and you are under no obligation to accept the quote.
How soon can hold-open devices be fitted in Haslemere?
Once the quote is accepted, supply is typically 1 to 3 weeks, and fitting a few devices on one floor usually takes a day. Larger jobs are planned in stages so doors are never left without protection. Your quote shows the expected programme, and fitting dates are agreed with you before work starts.
Do you service doors in Haslemere after installing them?
Yes. We recommend a trained engineer checks the safety functions at least once a year, with service intervals set by the manufacturer's instructions and how heavily the door is used; busy doors are often serviced more often. Servicing can follow on from the installation, with the price agreed in writing and a record left after every visit.
Can installation in Haslemere happen outside opening hours?
Yes. Many shops, surgeries and offices prefer work early in the morning, in the evening or at weekends, when the entrance is quietest. Tell us your constraints when you enquire and they are built into the plan. Any extra cost for out-of-hours work is shown in the written quote rather than added afterwards.
Who is responsible for automatic doors on escape routes in Haslemere?
Under the Regulatory Reform (Fire Safety) Order 2005 the responsible person for the premises must make sure escape routes work and fire safety equipment is maintained. Automatic doors on an escape route need fail-safe opening or break-out, set by the fire strategy.