Coverage across County Armagh
We treat County Armagh as one service area for automatic door refurbishment, so a site on the edge of the area gets the same written pricing and the same standard of work as one in the busiest town centre. Specialist automatic door engineers working under our management carry out each visit. Choose from the 4 towns below, or contact us with any address.
Towns listed in County Armagh: Craigavon, Portadown, Lurgan, Armagh.
What to think about for automatic door refurbishment in County Armagh
- Glass and made-to-measure leaves are typically 2 to 4 weeks from order. Plan the work around that lead time, especially if a damaged leaf is temporarily boarded.
- After refurbishment, sensors and speeds are reset to suit the new parts. Keep the test record with your service history so later engineers can see what was done.
- If the operator is close to the end of its life, refurbishing the running gear while fitting a new drive unit saves a second visit and a second set-up.
- Older shopfronts with discontinued door systems may need equivalent parts rather than exact matches. The survey identifies what is still available before anything is ordered.
- Listed buildings and conservation areas can limit changes to how the frame looks. Refurbishment within the existing frame usually avoids those issues and any need for consent.
Automatic door refurbishment in County Armagh: guide prices
The site survey is free, including the measured drawing and a fixed, itemised written quote. Guide price: from £395 ex VAT.
| Item | Guide price | Notes |
|---|---|---|
| Running gear refresh: rollers, guides, brushes and seals | £395 – £895 | per door, ex VAT |
| Track overhaul | £395 – £895 | per door, ex VAT |
| Replacement glass leaf | from £495 | each, ex VAT; size and glass type on survey |
| Full refurbishment of a sliding door | £1,495 – £2,995 | running gear, seals, guides and one leaf, ex VAT |
Standards and rules in Northern Ireland
Standards are not retrospective, so an older door does not become unlawful when a standard is updated; a site-specific risk assessment shows whether any upgrades are sensible. BS EN 16005 is the current standard for the safety in use of powered pedestrian doors, and BS 7036-0:2014 is the British code of practice for risk assessment and risk reduction used alongside it. Standards are not law in themselves, but they are the recognised benchmark for showing an automatic door is safe to use, and we set up, test and document doors with reference to them.
Whoever motorises a manual door, or builds an automatic door from separate parts, may take on the manufacturer’s legal duties for the finished door: a risk assessment, a technical file kept available for the authorities, a Declaration of Conformity, the conformity marking and instructions. You receive the Declaration of Conformity and the instructions at handover. In Northern Ireland machinery, including a new or converted powered door, carries the CE marking (with UKNI added where a UK body carried out the conformity assessment), and the EU Machinery Regulation applies there from 20 January 2027.
Workplace law (the Workplace (Health, Safety and Welfare) Regulations (Northern Ireland) 1993) expects powered doors to have suitable and effective features to stop them trapping anyone and, where needed for safety, to open by hand unless they open automatically if the power fails. Doors at work must also be kept in efficient working order under a suitable system of maintenance.
How it works
- Send photos and the address. A few pictures of the door from both sides, the address in County Armagh and a note of who uses the entrance help us understand the job before anyone visits the site.
- No-cost survey on site. We arrange a survey at a time that suits the building. The engineer records measurements, fixings and power, plus any constraints such as listed status, opening hours or access for deliveries.
- Itemised quote to approve. We price every element of the work on automatic door refurbishment separately in a written quote that you can check, share and approve. Lead time and payment stages are stated, and nothing is ordered until you accept.
- Fit, test and hand over. On the agreed dates the engineer installs the equipment, commissions the operator and tests each safety function. You get a demonstration, the test record and any conformity paperwork that applies to the work.
Book a free refurbishment survey in County Armagh. We will check the frame, leaves and running gear, then price each item separately on a fixed quote.
Automatic door refurbishment in County Armagh: questions
Can you replace a single broken glass leaf in County Armagh?
Yes. The leaf is made safe, measured and reglazed with new safety glass, or replaced completely if its frame is damaged. New glass is typically 2 to 4 weeks from order. Once the leaf is rehung, the door is set up again and the track and floor guide are checked.
What price range should I expect for automatic door refurbishment in County Armagh?
Our guide starts from £395 excluding VAT (per door), the same guide price we use across the UK. The free site survey in County Armagh confirms the price as a fixed, itemised written quote, and the guide price tool gives you a range before anyone visits.
Will our entrance in County Armagh stay open during refurbishment?
Often, at least in part. Many jobs can be done one leaf at a time, and the work can be planned for quieter hours. If the entrance does need to close, the quote says for how long, so you can arrange another way in for staff and visitors.
Is it worth refurbishing an old door at our premises in County Armagh?
If the frame is sound and the opening size still works, usually yes, as refurbishment costs far less than a new door. If the frame is corroded, the glass is not safety glass or the opening is too narrow, a new door may be better value, and the survey tells you which.
How are payments structured for work in County Armagh?
Payment stages are set out in the quote before you accept it. Larger or made-to-order jobs may involve a deposit and a balance on completion, while smaller jobs may be invoiced once the work is finished. Nothing is charged for the survey itself, and the terms you accept are the terms that apply.
What do you need from us for parking and access in County Armagh?
Somewhere for the engineer's van as close to the entrance as possible, and a clear working area around the door. If parking is restricted, loading rules apply or the site has security procedures, tell us when you book. Those details go into the plan so the visit is not held up on the day.
What do the building regulations in Northern Ireland say about powered doors?
The Building Regulations (Northern Ireland) 2012 require a powered door to have a means to prevent it trapping anyone and a means to open it if the power fails. Guidance on access is in Technical Booklet R, and new entrances need building control approval.