For access control for automatic doors anywhere in Surrey, you deal with one contracting party and one written price. We organise the visit, brief the engineer, who works under our management, and keep the paperwork together afterwards. Below you will find the towns we list in this part of England, 21 in all; if your address sits outside them, the arrangements are exactly the same.
Towns listed in Surrey: Woking, Guildford, Redhill, Staines-upon-Thames, Leatherhead, Ewell, Farnham, Epsom, Camberley, Egham, Sunbury-on-Thames, Ashford, Walton-on-Thames, Godalming, Reigate, Horley, Caterham, Weybridge, Molesey, Dorking, Haslemere.
What to think about for access control for automatic doors in Surrey
- Think about lost cards and leavers. A system that lets you remove a card centrally is easier to run than a shared keypad code on a busy site.
- Cable routes matter. Running cables between a reader, a controller and the operator through finished walls and ceilings can be a large share of the cost.
- Glass entrances may not have an obvious place for a reader. A post-mounted reader, or one fitted to a side screen, can avoid drilling into the door frame.
- Doors on escape routes need locks that release on alarm and on power loss. Check the fire strategy, or ask your fire risk assessor, before choosing a lock.
- Decide how the door should behave at each time of day before the survey. Opening hours, cleaning shifts, deliveries and weekend events all affect the schedule the door will follow.
Access control for automatic doors in Surrey: guide prices
The site survey is free, including the measured drawing and a fixed, itemised written quote. Guide price: from £795 ex VAT.
| Item | Guide price | Notes |
|---|---|---|
| Card or fob reader tied into the door | £795 – £2,495 | per door, ex VAT |
| Intercom or door entry tie-in | from £495 | priced on survey, ex VAT |
| Timed locking and night mode set-up | included with the above | programmed at commissioning |
| Electric lock added to an automatic door | on survey | depends on the door and the lock type |
Standards and rules in England
Under the Equality Act 2010, service providers and employers must make reasonable adjustments for disabled people, which can include altering a physical feature such as a heavy entrance door. Fitting an automatic door helps, but does not on its own guarantee those duties are met.
Building regulations guidance in England (Approved Document M, Volume 2) says a powered opening system should be used where a self-closing entrance door would need more than 30 N at the leading edge to open, or more than 22.5 N between 30° and 60°, and expects external doors used by the public in new buildings to give at least 1000 mm of effective clear width.
Whoever motorises a manual door, or builds an automatic door from separate parts, may take on the manufacturer’s legal duties for the finished door: a risk assessment, a technical file kept available for the authorities, a Declaration of Conformity, the conformity marking and instructions. You receive the Declaration of Conformity and the instructions at handover. In Great Britain a new or converted powered door must meet the Supply of Machinery (Safety) Regulations 2008 before it is first used, and can carry the UKCA or the CE marking.
How it works
- Get in touch. Call, email or use the form with the address and what you have in mind. If you are not sure which type of door suits, describe the entrance and we will suggest the options worth considering.
- Survey and advice. The survey costs nothing and carries no obligation. The engineer checks the site and explains which options suit the entrance, the people using it and the budget, before anything is priced.
- Quote in writing. You receive a fixed, itemised quote for access control for automatic doors in Surrey, covering equipment, installation, testing and handover, with the lead time and payment stages set out clearly.
- Install, test, explain. The engineer installs and commissions the door, tests the sensors, safety functions and emergency behaviour, and walks you through the controls. The handover pack records what was installed and tested.
Send us details of your current access control and the door in Surrey, and we will plan how to link the two.
Access control for automatic doors in Surrey: questions
Will our door in Surrey still release when the fire alarm sounds?
On an escape route, yes. Locks are wired to release on the fire alarm signal and, where the fire strategy requires it, the door opens and holds open. We test this with your fire alarm contractor at handover and record the result.
How much should I budget for access control for automatic doors in Surrey?
Our guide starts from £795 excluding VAT (per door), the same guide price we use across the UK. The free site survey in Surrey confirms the price as a fixed, itemised written quote, and the guide price tool gives you a range before anyone visits.
Our automatic door in Surrey is quite old. Can access control still be added?
Sometimes. Older operators may not have suitable inputs, or may not support an electric lock. The survey checks this, and if the operator needs upgrading first, the quote shows the cost of both, so you can decide. An older door may also benefit from a safety inspection at the same time.
Can you add access control to our automatic door in Surrey?
In most cases, yes. We check the operator's inputs, the lock options and the cable route at a free survey, then quote a fixed price. We can connect to your existing system or supply a standalone reader or keypad for the door.
Can installation in Surrey happen outside opening hours?
Yes. Many shops, surgeries and offices prefer work early in the morning, in the evening or at weekends, when the entrance is quietest. Tell us your constraints when you enquire and they are built into the plan. Any extra cost for out-of-hours work is shown in the written quote rather than added afterwards.
Do I need permission from a landlord or the council before work in Surrey?
It depends on the building. Tenants usually need the landlord's written consent before changing an entrance, and some changes to a shopfront or external door need planning permission. The survey notes anything that may need consent. We can supply drawings and product details to support an application, but the owner or tenant makes it.
Who is responsible for automatic doors on escape routes in Surrey?
Under the Regulatory Reform (Fire Safety) Order 2005 the responsible person for the premises must make sure escape routes work and fire safety equipment is maintained. Automatic doors on an escape route need fail-safe opening or break-out, set by the fire strategy.