UK-wide · Free site survey and fixed written quote for new doors · Repair and service visits priced before we attend

Call 0800 088 6248

Automatic Door Installers

Access control for automatic doors · Surrey

Access control for automatic doors in Epsom

Specialist engineers working under our management wire and commission access control on automatic doors across Epsom. They test each mode, each type of credential, the behaviour in a power cut and the alarm response before handing the door back to you.

Town
Epsom
Area
Surrey
Postcodes
KT18, KT19
Guide price
From £795 ex VAT
  • Free site survey for new doors
  • Fixed, itemised written quote
  • Set up with reference to BS EN 16005
  • England, Wales, Scotland and NI
  • Guide prices published

Covering Epsom and nearby

For access control for automatic doors, coverage around Epsom is set by postcode and includes the KT18 and KT19 postcode districts, as well as nearby addresses in Surrey. Specialist engineers working under our management attend each site, and the price is agreed in writing beforehand.

Libraries, health centres and council buildings in Epsom still need accessible entrances, whatever their size. A single automatic door with a push pad or touch-free switch is often enough to give everyone easy access.

Nearby towns we also list for access control for automatic doors (straight-line distance): Ewell (1.6 miles), Sutton (3.3 miles), Leatherhead (3.6 miles), Surbiton (4.4 miles), Carshalton (5.1 miles), Morden (5.6 miles).

What to think about for access control for automatic doors in Epsom

  • Think about lost cards and leavers. A system that lets you remove a card centrally is easier to run than a shared keypad code on a busy site.
  • Doors on escape routes need locks that release on alarm and on power loss. Check the fire strategy, or ask your fire risk assessor, before choosing a lock.
  • Residential blocks in Epsom usually have a managing agent or housing provider who sets the rules for fobs, visitors and fire alarm behaviour. Involve them early.
  • Cable routes matter. Running cables between a reader, a controller and the operator through finished walls and ceilings can be a large share of the cost.
  • Healthcare sites in Epsom often control access to wards and staff areas. Think about how visitors, porters and emergency teams will get through at every hour.

Access control for automatic doors in Epsom: guide prices

The site survey is free, including the measured drawing and a fixed, itemised written quote. Guide price: from £795 ex VAT.

ItemGuide priceNotes
Card or fob reader tied into the door£795 – £2,495per door, ex VAT
Intercom or door entry tie-infrom £495priced on survey, ex VAT
Timed locking and night mode set-upincluded with the aboveprogrammed at commissioning
Electric lock added to an automatic dooron surveydepends on the door and the lock type

Standards and rules in England

Building regulations guidance in England (Approved Document M, Volume 2) says a powered opening system should be used where a self-closing entrance door would need more than 30 N at the leading edge to open, or more than 22.5 N between 30° and 60°, and expects external doors used by the public in new buildings to give at least 1000 mm of effective clear width.

Whoever motorises a manual door, or builds an automatic door from separate parts, may take on the manufacturer’s legal duties for the finished door: a risk assessment, a technical file kept available for the authorities, a Declaration of Conformity, the conformity marking and instructions. You receive the Declaration of Conformity and the instructions at handover. In Great Britain a new or converted powered door must meet the Supply of Machinery (Safety) Regulations 2008 before it is first used, and can carry the UKCA or the CE marking.

How it works

  1. Get in touch. Call, email or use the form with the address and what you have in mind. If you are not sure which type of door suits, describe the entrance and we will suggest the options worth considering.
  2. Survey and advice. The survey costs nothing and carries no obligation. The engineer checks the site and explains which options suit the entrance, the people using it and the budget, before anything is priced.
  3. Quote in writing. You receive a fixed, itemised quote for access control for automatic doors in Epsom, covering equipment, installation, testing and handover, with the lead time and payment stages set out clearly.
  4. Install, test, explain. The engineer installs and commissions the door, tests the sensors, safety functions and emergency behaviour, and walks you through the controls. The handover pack records what was installed and tested.

Send us details of your current access control and the door in Epsom, and we will plan how to link the two.

Access control for automatic doors in Epsom: questions

Do you work with our security installer in Epsom?

Yes. Where a security installer already looks after your access control, we usually handle the door, the lock and the link to the operator, and they handle the reader, controller and permissions. The quote sets out who does what so nothing falls between the two.

How are prices worked out for access control for automatic doors in Epsom?

Our guide starts from £795 excluding VAT (per door), the same guide price we use across the UK. The free site survey in Epsom confirms the price as a fixed, itemised written quote, and the guide price tool gives you a range before anyone visits.

Can you add access control to our automatic door in Epsom?

In most cases, yes. We check the operator's inputs, the lock options and the cable route at a free survey, then quote a fixed price. We can connect to your existing system or supply a standalone reader or keypad for the door.

How long does installation take at our building in Epsom?

Lead time is typically 2 to 4 weeks from order. Most single doors are wired and commissioned in a day, though longer cable runs or several doors take more time. We agree working hours with you so the entrance stays usable.

Will the building stay secure while the entrance is being changed?

We plan to keep the entrance usable or secure throughout. Where a door has to come out, the work is sequenced so the opening is closed up before the engineer leaves, or a temporary door or hoarding is arranged when a longer gap cannot be avoided. How this is handled for your site in Epsom is agreed before work starts.

Can automatic doors be fitted to a listed building in Epsom?

Often, yes, but listed building consent is normally needed for changes that affect the character of the building, inside or out. Slim operators, concealed fixings and automating the existing door can all reduce the visual impact. Speak to the conservation officer at the local planning authority early; we can provide drawings and specifications to help.

Who is responsible for automatic doors on escape routes in Epsom?

Under the Regulatory Reform (Fire Safety) Order 2005 the responsible person for the premises must make sure escape routes work and fire safety equipment is maintained. Automatic doors on an escape route need fail-safe opening or break-out, set by the fire strategy.

Next step

Access control for automatic doors in Epsom

Send the address, a photo if you have one and what the door needs to do. New installations get a free site survey and a fixed written quote; repairs and servicing are priced in writing before we attend.