Covering Oban and nearby
Engineers working under our management travel to addresses across the PA34 postcode district for drive unit replacement. There is no depot or showroom in Oban; you arrange everything with us by phone, email or the form on this page, and we confirm the price in writing first.
Libraries, health centres and council buildings in Oban still need accessible entrances, whatever their size. A single automatic door with a push pad or touch-free switch is often enough to give everyone easy access.
What to think about for drive unit replacement in Oban
- Worn floor guides and rollers can shorten the life of a new operator. It is often worth replacing them during the same visit rather than coming back later.
- Heavy glass leaves need an operator rated for their weight. The survey records the size and glass type of each leaf so the right drive unit is specified.
- Check the power supply. A dedicated fused spur and isolator near the door is usually needed, and older installations sometimes need electrical work before the new operator goes in.
- Ask for the paperwork. A converted door should come with its risk assessment, Declaration of Conformity and user instructions, which belong with your building and maintenance records.
- Busy retail entrances in Oban may prefer the changeover after closing time or on a quiet trading day. Tell us your hours when you book the survey.
Drive unit replacement in Oban: guide prices
The site survey is free, including the measured drawing and a fixed, itemised written quote. Guide price: typically £1,995 to £3,995 ex VAT.
| Item | Guide price | Notes |
|---|---|---|
| New drive unit on an existing automatic sliding door | £1,995 – £3,995 | existing leaves kept, installed, ex VAT |
| New operator on an existing automatic swing door | £1,795 – £3,995 | installed, ex VAT |
| Sensors replaced at the same time | £195 – £495 | per sensor, ex VAT |
Standards and rules in Scotland
Workplace law (the Workplace (Health, Safety and Welfare) Regulations 1992) expects powered doors to have suitable and effective features to stop them trapping anyone and, where needed for safety, to open by hand unless they open automatically if the power fails. Doors at work must also be kept in efficient working order under a suitable system of maintenance.
Standards are not retrospective, so an older door does not become unlawful when a standard is updated; a site-specific risk assessment shows whether any upgrades are sensible. BS EN 16005 is the current standard for the safety in use of powered pedestrian doors, and BS 7036-0:2014 is the British code of practice for risk assessment and risk reduction used alongside it. Standards are not law in themselves, but they are the recognised benchmark for showing an automatic door is safe to use, and we set up, test and document doors with reference to them.
How it works
- Get in touch. Call, email or use the form with the address and what you have in mind. If you are not sure which type of door suits, describe the entrance and we will suggest the options worth considering.
- Survey and advice. The survey costs nothing and carries no obligation. The engineer checks the site and explains which options suit the entrance, the people using it and the budget, before anything is priced.
- Quote in writing. You receive a fixed, itemised quote for drive unit replacement in Oban, covering equipment, installation, testing and handover, with the lead time and payment stages set out clearly.
- Install, test, explain. The engineer installs and commissions the door, tests the sensors, safety functions and emergency behaviour, and walks you through the controls. The handover pack records what was installed and tested.
Book a free survey in Oban to find out whether a new drive unit will bring your automatic door back to reliable use. The quote is fixed and itemised.
Drive unit replacement in Oban: questions
How long will our entrance in Oban be closed for the changeover?
A standard sliding door changeover typically takes a day, and a swing operator often less. The work can be scheduled early, after closing or at a weekend so it causes less disruption. Your quote shows the planned date and how long the entrance will be out of use.
How much should I budget for drive unit replacement in Oban?
Our guide is £1,995 to £3,995 excluding VAT (per door), the same guide prices we use across the UK. The free site survey in Oban confirms the price as a fixed, itemised written quote, and the guide price tool gives you a range before anyone visits.
Will you remove the old operator from our premises in Oban?
Yes. The old drive unit, sensors and any other replaced parts are taken away as part of the job, and the work area is left clean. Disposal is included in the fixed quote, so there is nothing extra to arrange or pay for afterwards.
What if the frame of our door in Oban is not worth keeping?
Then we will tell you. Damaged or corroded frames, glass that is not safety glass, or an opening that is too narrow for the people using it are all reasons to choose a new door instead. We can quote both options so you can compare them side by side.
How do you make sure the door works for disabled visitors in Oban?
We look at who uses the entrance: wheelchair users, people with walking aids, parents with buggies and older visitors. That shapes the opening width, the opening speed, the hold-open time and where push pads or sensors go. Service providers and employers have duties to make reasonable adjustments under equality and accessibility law, and an automatic door is a common one.
What is the lead time for drive unit replacement in Oban?
Lead times depend on the door type and what has to be made to order. As a guide, operators and accessible door kits are typically two to four weeks from order, and complete sliding entrances typically four to eight weeks from drawing approval. Curved, revolving and hermetic doors usually take longer. The expected lead time is stated in your quote.
Do businesses in Oban have to fit automatic doors?
No law requires automatic doors everywhere. Under the Equality Act 2010 service providers and employers must make reasonable adjustments for disabled people, and Scottish guidance says powered doors improve accessibility at entrances. An automatic door is often the practical answer.