UK-wide · Free site survey and fixed written quote for new doors · Repair and service visits priced before we attend

Call 0800 088 6248

Automatic Door Installers

Fire door hold-open devices · England

Fire door hold-open devices in West Sussex

Care homes, offices and schools in West Sussex often have fire doors wedged open because they are too heavy for daily use. We replace the wedges with alarm-linked hold-open devices, chosen to suit each door, after a free survey and a fixed, itemised quote.

Area
West Sussex
Nation
England
Towns listed
11
Guide price
From £145 ex VAT
  • Free site survey for new doors
  • Fixed, itemised written quote
  • Set up with reference to BS EN 16005
  • England, Wales, Scotland and NI
  • Guide prices published

Coverage across West Sussex

Not every part of West Sussex is easy to reach, and some sites need planning around access, parking or opening hours. We take that into account when arranging fire door hold-open devices, and the engineer, working under our management, arrives with what the job is likely to need. The towns below, 11 in all, each have their own page, but any address in the area can be covered.

Towns listed in West Sussex: Crawley, Worthing, Bognor Regis, Littlehampton, Horsham, Haywards Heath, Chichester, Burgess Hill, East Grinstead, Shoreham-by-Sea, Lancing.

What to think about for fire door hold-open devices in West Sussex

  • Busy office corridors suit wall magnets that hold doors right back against the wall, out of the way of people and trolleys, until the alarm releases them.
  • Listed buildings and conservation areas can make new cable runs difficult. Radio-triggered battery units avoid most wiring, although the transmitter still needs a connection at the alarm panel.
  • Background noise matters for acoustic units. Kitchens, plant areas and busy receptions may be too loud for a unit that listens for the alarm, so a wired or radio device is often better there.
  • If the alarm panel has no spare outputs, a relay or an extra interface may be needed. Your alarm engineer can confirm this, and it is added to the quote once agreed.
  • Older buildings in West Sussex may have fire doors that no longer close fully on their own. A hold-open device cannot fix that, so the survey checks closers, hinges and latches first.

Fire door hold-open devices in West Sussex: guide prices

The site survey is free, including the measured drawing and a fixed, itemised written quote. Guide price: from £145 ex VAT.

ItemGuide priceNotes
Battery acoustic hold-open unit£145 – £295per door, fitted, ex VAT
Hard-wired hold-open magnet linked to the fire alarm£245 – £595per door, ex VAT; alarm panel work extra
Free-swing door closer linked to the fire alarm£395 – £895per door, fitted, ex VAT

Which hold-open device is suitable depends on your fire risk assessment. Linking to the fire alarm may need work by your alarm engineer.

Standards and rules in England

Fire doors that are held open must close automatically when the fire alarm operates. Where hold-open devices can be used is decided by the fire risk assessment, which is the job of the responsible person under the Regulatory Reform (Fire Safety) Order 2005.

Hold-open devices and door release units linked to the fire alarm need regular testing as part of the building’s fire safety checks, and the results should be recorded.

Workplace law (the Workplace (Health, Safety and Welfare) Regulations 1992) expects powered doors to have suitable and effective features to stop them trapping anyone and, where needed for safety, to open by hand unless they open automatically if the power fails. Doors at work must also be kept in efficient working order under a suitable system of maintenance.

How it works

  1. Describe what you need. Whether the job is fire door hold-open devices for a busy entrance or for a single internal door, a brief description and some photos let us understand it and plan a survey visit in West Sussex.
  2. Free visit to the site. An engineer working under our management assesses the opening, the existing door and frame, the floor and the electrical supply, and notes any access, consent or timing issues to plan around.
  3. Your fixed quotation. The quote is fixed for the work it describes and lists each item, including any removal, making good and electrical work. It also states the lead time, the payment stages and the warranty terms.
  4. Fitting and sign-off. Work goes ahead on dates agreed with you. Once fitted, the door is adjusted and its safety functions are tested and recorded with reference to BS EN 16005, and you are shown how to use it.

Tell us about the fire doors that cause problems in West Sussex. We will survey them free of charge and explain which hold-open options your alarm can support.

Fire door hold-open devices in West Sussex: questions

How soon can hold-open devices be fitted in West Sussex?

Once the quote is accepted, supply is typically 1 to 3 weeks, and fitting a few devices on one floor usually takes a day. Larger jobs are planned in stages so doors are never left without protection. Your quote shows the expected programme, and fitting dates are agreed with you before work starts.

What is the guide price for fire door hold-open devices in West Sussex?

Our guide starts from £145 excluding VAT (per door), the same guide price we use across the UK. The free site survey in West Sussex confirms the price as a fixed, itemised written quote, and the guide price tool gives you a range before anyone visits.

Can you work with the fire alarm company that maintains our system in West Sussex?

Yes, and for wired devices we usually need to. The connection at the alarm panel is made by, or agreed with, the engineer who looks after your alarm. We share the device details with them and agree the visits, so the alarm and the doors can be tested together once the work is finished.

Are battery hold-open units a good choice for older buildings in West Sussex?

Often they are. Radio and acoustic battery units avoid long cable runs, which helps in older or listed buildings and finished corridors. Acoustic units are only suitable where the fire risk assessment allows them and the alarm can be heard clearly at the door. Batteries need replacing at the interval the maker states.

What happens once the installation in West Sussex is finished?

The engineer tests every function, including the safety sensors and the behaviour on power loss, and sets the door up with reference to BS EN 16005. You are shown how to use the controls and which simple checks to make, and you receive the handover documents, including the test record and any conformity paperwork that applies to the work.

Do you service doors in West Sussex after installing them?

Yes. We recommend a trained engineer checks the safety functions at least once a year, with service intervals set by the manufacturer's instructions and how heavily the door is used; busy doors are often serviced more often. Servicing can follow on from the installation, with the price agreed in writing and a record left after every visit.

Which building regulations apply to a new automatic entrance in West Sussex?

In England the guidance is Approved Document M (Volume 2) for access, Approved Document B for fire safety and escape routes, and Approved Document K for glazing and powered doors. A new entrance can count as building work, so building control should be involved before it is ordered.

Next step

Fire door hold-open devices in West Sussex

Send the address, a photo if you have one and what the door needs to do. New installations get a free site survey and a fixed written quote; repairs and servicing are priced in writing before we attend.