Coverage across County Tyrone
Coverage for fire door hold-open devices extends across all of County Tyrone, including addresses some distance from the towns listed below. We are the contracting party, the engineers work under our management, and the price is agreed in writing first. If your town is not among the 4 we list, contact us anyway; the process and guide prices do not change.
Towns listed in County Tyrone: Omagh, Strabane, Dungannon, Cookstown.
What to think about for fire door hold-open devices in County Tyrone
- Hard-wired magnets need a power supply near each door. In buildings in County Tyrone where that is awkward, battery units avoid running new cables along finished corridors.
- Care homes in County Tyrone usually want bedroom doors that residents can open easily. Free-swing closers suit this, provided the evacuation strategy for the home supports them.
- Busy office corridors suit wall magnets that hold doors right back against the wall, out of the way of people and trolleys, until the alarm releases them.
- Residential blocks often have communal corridor doors that residents prop open. Hold-open devices give the same convenience while letting the doors close when the alarm sounds.
- Think about who tests the fire alarm each week at your building in County Tyrone. Adding a walk past the held-open doors to that test is the easiest way to confirm they release.
Fire door hold-open devices in County Tyrone: guide prices
The site survey is free, including the measured drawing and a fixed, itemised written quote. Guide price: from £145 ex VAT.
| Item | Guide price | Notes |
|---|---|---|
| Battery acoustic hold-open unit | £145 – £295 | per door, fitted, ex VAT |
| Hard-wired hold-open magnet linked to the fire alarm | £245 – £595 | per door, ex VAT; alarm panel work extra |
| Free-swing door closer linked to the fire alarm | £395 – £895 | per door, fitted, ex VAT |
Which hold-open device is suitable depends on your fire risk assessment. Linking to the fire alarm may need work by your alarm engineer.
Standards and rules in Northern Ireland
Fire doors that are held open must close automatically when the fire alarm operates. Where hold-open devices can be used is decided by the fire risk assessment, which is the job of the person with fire safety duties under the Fire and Rescue Services (Northern Ireland) Order 2006.
Hold-open devices and door release units linked to the fire alarm need regular testing as part of the building’s fire safety checks, and the results should be recorded.
Workplace law (the Workplace (Health, Safety and Welfare) Regulations (Northern Ireland) 1993) expects powered doors to have suitable and effective features to stop them trapping anyone and, where needed for safety, to open by hand unless they open automatically if the power fails. Doors at work must also be kept in efficient working order under a suitable system of maintenance.
How it works
- Send photos and the address. A few pictures of the door from both sides, the address in County Tyrone and a note of who uses the entrance help us understand the job before anyone visits the site.
- No-cost survey on site. We arrange a survey at a time that suits the building. The engineer records measurements, fixings and power, plus any constraints such as listed status, opening hours or access for deliveries.
- Itemised quote to approve. We price every element of the work on fire door hold-open devices separately in a written quote that you can check, share and approve. Lead time and payment stages are stated, and nothing is ordered until you accept.
- Fit, test and hand over. On the agreed dates the engineer installs the equipment, commissions the operator and tests each safety function. You get a demonstration, the test record and any conformity paperwork that applies to the work.
Ask for a hold-open survey in County Tyrone. We will check each door and the alarm system, then quote a fixed price with the right device for every opening.
Fire door hold-open devices in County Tyrone: questions
What will the survey in County Tyrone look at?
The engineer checks that each door closes and latches from fully open, the condition of the closer and seals, where the door rests when open, nearby power supplies and the alarm panel or radio options. We also ask to see the relevant part of the fire risk assessment, so the quote covers only doors that can be held open.
What do you charge for fire door hold-open devices in County Tyrone?
Our guide starts from £145 excluding VAT (per door), the same guide price we use across the UK. The free site survey in County Tyrone confirms the price as a fixed, itemised written quote, and the guide price tool gives you a range before anyone visits.
Will you test the hold-open devices before leaving our site in County Tyrone?
Yes. Every door is released from fully open and checked to close and latch. Where the alarm connection is complete, the doors are also tested with the alarm itself. You receive a schedule of the doors and devices fitted, ready to keep with your fire safety records and weekly alarm test log.
How soon can hold-open devices be fitted in County Tyrone?
Once the quote is accepted, supply is typically 1 to 3 weeks, and fitting a few devices on one floor usually takes a day. Larger jobs are planned in stages so doors are never left without protection. Your quote shows the expected programme, and fitting dates are agreed with you before work starts.
What happens once the installation in County Tyrone is finished?
The engineer tests every function, including the safety sensors and the behaviour on power loss, and sets the door up with reference to BS EN 16005. You are shown how to use the controls and which simple checks to make, and you receive the handover documents, including the test record and any conformity paperwork that applies to the work.
How much disruption should we expect while the work is done in County Tyrone?
Most installations take one visit or a short series of visits, with dust and noise kept to the area around the door. The engineer screens off the work area, keeps a route in or out where possible and clears up before leaving. Larger entrances, lobbies or structural changes take longer, and the quote explains how that work is phased.
What do the building regulations in Northern Ireland say about powered doors?
The Building Regulations (Northern Ireland) 2012 require a powered door to have a means to prevent it trapping anyone and a means to open it if the power fails. Guidance on access is in Technical Booklet R, and new entrances need building control approval.