Fire door hold-open devices in March

Care homes, offices and schools in March often have fire doors wedged open because they are too heavy for daily use. We replace the wedges with alarm-linked hold-open devices, chosen to suit each door, after a free survey and a fixed, itemised quote.

Town
March
Area
Cambridgeshire
Postcodes
PE15
Guide price
From £145 ex VAT
  • Free site survey for new doors
  • Fixed, itemised written quote
  • Set up with reference to BS EN 16005
  • England, Wales, Scotland and NI
  • Guide prices published

Covering March and nearby

Sites across the PE15 postcode district are visited by specialist automatic door engineers working under our management. They travel to March for fire door hold-open devices as bookings come in, so dates depend on the diary rather than a fixed local team, and we give you the earliest date we can offer when you book.

Independent businesses in March often have one entrance and cannot close for long. Work is usually scheduled early, late or on a quiet day, and where a door must be out of use for a period, we plan to keep the entrance usable or secure.

Nearby towns we also list for fire door hold-open devices (straight-line distance): Wisbech (8.5 miles), Ely (12.8 miles), Peterborough (14.2 miles), King's Lynn (18.9 miles), Spalding (19.1 miles), Huntingdon (19.2 miles).

What to think about for fire door hold-open devices in March

  • Fire doors on stairs and protected escape routes need particular care. The fire risk assessment may allow some of them to be held open and not others, so pricing is door by door.
  • Care homes in March usually want bedroom doors that residents can open easily. Free-swing closers suit this, provided the evacuation strategy for the home supports them.
  • Listed buildings and conservation areas can make new cable runs difficult. Radio-triggered battery units avoid most wiring, although the transmitter still needs a connection at the alarm panel.
  • Schools and colleges in March may want hold-open devices fitted during the holidays so corridors are not disrupted in term time. Fitting can be planned around term dates.
  • Background noise matters for acoustic units. Kitchens, plant areas and busy receptions may be too loud for a unit that listens for the alarm, so a wired or radio device is often better there.

Fire door hold-open devices in March: guide prices

The site survey is free, including the measured drawing and a fixed, itemised written quote. Guide price: from £145 ex VAT.

ItemGuide priceNotes
Battery acoustic hold-open unit£145 – £295per door, fitted, ex VAT
Hard-wired hold-open magnet linked to the fire alarm£245 – £595per door, ex VAT; alarm panel work extra
Free-swing door closer linked to the fire alarm£395 – £895per door, fitted, ex VAT

Which hold-open device is suitable depends on your fire risk assessment. Linking to the fire alarm may need work by your alarm engineer.

Standards and rules in England

Workplace law (the Workplace (Health, Safety and Welfare) Regulations 1992) expects powered doors to have suitable and effective features to stop them trapping anyone and, where needed for safety, to open by hand unless they open automatically if the power fails. Doors at work must also be kept in efficient working order under a suitable system of maintenance.

Fire doors that are held open must close automatically when the fire alarm operates. Where hold-open devices can be used is decided by the fire risk assessment, which is the job of the responsible person under the Regulatory Reform (Fire Safety) Order 2005.

How it works

  1. Describe what you need. Whether the job is fire door hold-open devices for a busy entrance or for a single internal door, a brief description and some photos let us understand it and plan a survey visit in March.
  2. Free visit to the site. An engineer working under our management assesses the opening, the existing door and frame, the floor and the electrical supply, and notes any access, consent or timing issues to plan around.
  3. Your fixed quotation. The quote is fixed for the work it describes and lists each item, including any removal, making good and electrical work. It also states the lead time, the payment stages and the warranty terms.
  4. Fitting and sign-off. Work goes ahead on dates agreed with you. Once fitted, the door is adjusted and its safety functions are tested and recorded with reference to BS EN 16005, and you are shown how to use it.

For care homes, offices and schools in March, we survey, quote and fit alarm-linked hold-open devices. Get in touch to arrange a time that suits your building.

Fire door hold-open devices in March: questions

Which doors in my building in March can be held open?

That is decided by the fire risk assessment for the building, not by the installer. Many corridor, lounge and office doors can be held open on a device that releases on the alarm, while some stair and escape route doors cannot. If the assessment is unclear, check with your assessor before we finalise the quote.

Is there a guide price for fire door hold-open devices in March?

Our guide starts from £145 excluding VAT (per door), the same guide price we use across the UK. The free site survey in March confirms the price as a fixed, itemised written quote, and the guide price tool gives you a range before anyone visits.

Will you test the hold-open devices before leaving our site in March?

Yes. Every door is released from fully open and checked to close and latch. Where the alarm connection is complete, the doors are also tested with the alarm itself. You receive a schedule of the doors and devices fitted, ready to keep with your fire safety records and weekly alarm test log.

How soon can hold-open devices be fitted in March?

Once the quote is accepted, supply is typically 1 to 3 weeks, and fitting a few devices on one floor usually takes a day. Larger jobs are planned in stages so doors are never left without protection. Your quote shows the expected programme, and fitting dates are agreed with you before work starts.

What does the free site survey in March involve?

An engineer working under our management visits the building, measures the opening, checks the frame, floor, head height and power supply, and looks at how people use the entrance. The survey is free and carries no obligation. Afterwards you receive a fixed, itemised written quote for fire door hold-open devices, with drawings where the door type needs them.

Do you service doors in March after installing them?

Yes. We recommend a trained engineer checks the safety functions at least once a year, with service intervals set by the manufacturer's instructions and how heavily the door is used; busy doors are often serviced more often. Servicing can follow on from the installation, with the price agreed in writing and a record left after every visit.

Who is responsible for automatic doors on escape routes in March?

Under the Regulatory Reform (Fire Safety) Order 2005 the responsible person for the premises must make sure escape routes work and fire safety equipment is maintained. Automatic doors on an escape route need fail-safe opening or break-out, set by the fire strategy.