Coverage across the Highlands
Not every part of the Highlands is easy to reach, and some sites need planning around access, parking or opening hours. We take that into account when arranging break-out escape route doors, and the engineer, working under our management, arrives with what the job is likely to need. The towns below, 6 in all, each have their own page, but any address in the area can be covered.
Towns listed in the Highlands: Inverness, Fort William, Nairn, Thurso, Wick, Portree.
What to think about for break-out escape route doors in the Highlands
- Listed buildings and conservation areas in the Highlands may need consent before a new entrance goes in. Slim frames and the existing opening can often be kept, but check with the planning authority before ordering.
- Check the swing zone outside the entrance. Planters, cycle stands, bins and A-boards that are harmless beside a normal door can stop a break-out leaf opening fully, so plan to keep that area clear.
- Think about night security alongside escape. A lock that stops a leaf breaking out while people are still inside causes problems, so choose one that releases on the fire alarm where the strategy calls for it.
- If a canopy, ramp or steps sit close to the door, measure how far a broken-out leaf will travel. A leaf that clips a handrail or step edge will not give the escape width the strategy assumes.
- Older entrances on high streets in the Highlands may have uneven thresholds or sloping pavements. Break-out leaves need a level floor and solid fixing for the bottom pivots, and correcting that can add a day to the work.
Break-out escape route doors in the Highlands: guide prices
The site survey is free, including the measured drawing and a fixed, itemised written quote. Guide price: from £7,995 ex VAT.
| Item | Guide price | Notes |
|---|---|---|
| Break-out sliding door set for an escape route | from £7,995 | installed, ex VAT; typically up to £16,995 |
| Converting an existing sliding door to break-out | Priced on survey | depends on the frame, leaves and operator |
| Battery backup for power-cut operation | £395 – £695 | per door, ex VAT |
| Touch-free switch or push pad, fitted | £145 – £395 | per switch, ex VAT |
Standards and rules in Scotland
In Scotland, fire safety regulations say sliding or revolving doors must not be used for exits specifically intended as emergency exits, and Scottish guidance allows automatic and revolving doors on an escape route only where they fail safely to outward opening, or have a monitored fail-safe system that opens them on power failure, sensor failure and fire alarm. Whether a break-out door is suitable is decided by the fire strategy for the building and the person responsible for fire safety under the Fire (Scotland) Act 2005.
In Great Britain a new or converted powered door must meet the Supply of Machinery (Safety) Regulations 2008 before it is first used, and can carry the UKCA or the CE marking. Workplace law (the Workplace (Health, Safety and Welfare) Regulations 1992) expects powered doors to have suitable and effective features to stop them trapping anyone and, where needed for safety, to open by hand unless they open automatically if the power fails. Doors at work must also be kept in efficient working order under a suitable system of maintenance.
Scottish building standards guidance (the non-domestic Technical Handbook) expects an accessible entrance door to give a clear opening of at least 800 mm, says powered doors improve accessibility as long as they add no new hazard, and expects signage, sensors that hold the door open long enough, and guarding against collision or entrapment.
How it works
- Start with a short enquiry. Use the form, phone or email. Tell us whether the work is a new door, an upgrade or an opener for a home, and we arrange the next step for your site in the Highlands.
- Measured survey. The free survey confirms what will fit and what the entrance needs: opening width, door type, activation, safety sensors and behaviour on power loss or fire alarm, matched to how the building is used.
- Written price, no surprises. A fixed, itemised quote sets out the specification, the work involved, the expected lead time and the warranty terms. You can ask questions or change the specification before accepting it.
- Installed and commissioned. The door is installed with as little disruption as possible, then set up and tested for its hazard zones. Before leaving, the engineer explains the controls and hands over the documents for your records.
Tell us about the building in the Highlands, its footfall and its fire alarm, and we will plan a break-out door around them, starting with a free site visit.
Break-out escape route doors in the Highlands: questions
Do you install break-out sliding doors in the Highlands?
Yes. We arrange surveys and installations in the Highlands through specialist automatic door engineers working under our management. We supply the complete entrance, set it up to the fire strategy you give us, test it in every mode and hand over the records. The survey is free and the quote is fixed.
How are prices worked out for break-out escape route doors in the Highlands?
Our guide starts from £7,995 excluding VAT (per door set), the same guide price we use across the UK. The free site survey in the Highlands confirms the price as a fixed, itemised written quote, and the guide price tool gives you a range before anyone visits.
We have an old sliding door in the Highlands. Do we have to replace all of it?
Not always. If the frame and operator can take break-out leaves and parts are still available, a conversion may be possible. If the door is older or its parts are unsupported, replacing the whole entrance is usually more reliable. The survey looks at both and the quote explains the difference.
Our shop in the Highlands is inside a shopping centre. Can you still fit a break-out door?
In most cases, yes. Centre management usually sets rules on contractors, working hours and connections to the centre's fire alarm. We work within those rules, provide the method statements and insurance details they ask for, and plan the fitting so the unit can trade for as much of the time as possible.
What happens once the installation in the Highlands is finished?
The engineer tests every function, including the safety sensors and the behaviour on power loss, and sets the door up with reference to BS EN 16005. You are shown how to use the controls and which simple checks to make, and you receive the handover documents, including the test record and any conformity paperwork that applies to the work.
Will the building stay secure while the entrance is being changed?
We plan to keep the entrance usable or secure throughout. Where a door has to come out, the work is sequenced so the opening is closed up before the engineer leaves, or a temporary door or hoarding is arranged when a longer gap cannot be avoided. How this is handled for your site in the Highlands is agreed before work starts.
Is a building warrant needed for a new automatic entrance in the Highlands?
Often, yes. Most building work in Scotland needs a building warrant before it starts, and the non-domestic Technical Handbook sets out what an accessible entrance should provide, including a clear opening of at least 800 mm. We tell you at the survey if your job is likely to need one.