Coverage across Perth and Kinross
Here is how coverage works in Perth and Kinross. You contact us with the address and what the door needs, we confirm the price in writing, and a specialist engineer working under our management attends on an agreed date. That applies to automatic swing doors at a single shop door or across a whole estate of buildings, in any of the towns below or between them.
Towns listed in Perth and Kinross: Perth, Blairgowrie, Crieff.
What to think about for automatic swing doors in Perth and Kinross
- Electric locks must be coordinated with the operator, so the lock releases before the arm moves. Tell us about existing locks, card readers and intercoms at the survey.
- Hospital and care home corridors in Perth and Kinross need doors that open early enough for beds and trolleys. Radar sensors set to the right range, or a push pad placed before the door, keep traffic moving.
- Doors that open into a corridor can strike people approaching from the side. Guard rails or extra sensors may be needed where the swing area meets a busy route.
- External swing doors facing the wind need stronger operators and careful set-up. On exposed sites across Perth and Kinross, consider whether a canopy or a sliding door would work better.
- Fire doors need care. The operator must suit the door, keep its fire performance intact and close the door when the alarm sounds, so have the door's labels and records to hand for the survey.
Automatic swing doors in Perth and Kinross: guide prices
The site survey is free, including the measured drawing and a fixed, itemised written quote. Guide price: from £2,495 ex VAT.
| Item | Guide price | Notes |
|---|---|---|
| Full-energy operator on an existing single door, with safety sensors | £2,495 – £3,995 | installed, ex VAT |
| Operators on an existing pair of doors | £3,795 – £6,495 | installed, ex VAT |
| New single automatic swing door set (door, frame and operator) | £3,495 – £6,495 | installed, ex VAT |
| New double automatic swing door set | £7,995 – £9,995 | installed, ex VAT |
| Touch-free switch or push pad, fitted | £145 – £395 | per switch, ex VAT |
| Card or fob reader tied into the door | £795 – £2,495 | per door, ex VAT |
Standards and rules in Scotland
Scottish building standards guidance (the non-domestic Technical Handbook) expects an accessible entrance door to give a clear opening of at least 800 mm, says powered doors improve accessibility as long as they add no new hazard, and expects signage, sensors that hold the door open long enough, and guarding against collision or entrapment.
In Great Britain a new or converted powered door must meet the Supply of Machinery (Safety) Regulations 2008 before it is first used, and can carry the UKCA or the CE marking. Workplace law (the Workplace (Health, Safety and Welfare) Regulations 1992) expects powered doors to have suitable and effective features to stop them trapping anyone and, where needed for safety, to open by hand unless they open automatically if the power fails. Doors at work must also be kept in efficient working order under a suitable system of maintenance.
Under the Equality Act 2010, service providers and employers in Scotland must make reasonable adjustments for disabled people, which can include altering a physical feature such as a heavy entrance door. Most building work in Scotland needs a building warrant before it starts, so new entrances are checked with the local authority verifier first.
How it works
- Start with a short enquiry. Use the form, phone or email. Tell us whether the work is a new door, an upgrade or an opener for a home, and we arrange the next step for your site in Perth and Kinross.
- Measured survey. The free survey confirms what will fit and what the entrance needs: opening width, door type, activation, safety sensors and behaviour on power loss or fire alarm, matched to how the building is used.
- Written price, no surprises. A fixed, itemised quote sets out the specification, the work involved, the expected lead time and the warranty terms. You can ask questions or change the specification before accepting it.
- Installed and commissioned. The door is installed with as little disruption as possible, then set up and tested for its hazard zones. Before leaving, the engineer explains the controls and hands over the documents for your records.
For corridor, office or school doors in Perth and Kinross, send us photos and door sizes and we will plan the right swing operators.
Automatic swing doors in Perth and Kinross: questions
Do you fit low-energy operators in Perth and Kinross as well?
Yes. Where a door is quieter and used mainly by people who need help opening it, a low-energy operator may be the better choice, as long as a risk assessment shows it is suitable. We compare full-energy and low-energy at the survey and explain the difference in the quote.
How much should I budget for automatic swing doors in Perth and Kinross?
Our guide starts from £2,495 excluding VAT (per door), the same guide price we use across the UK. The free site survey in Perth and Kinross confirms the price as a fixed, itemised written quote, and the guide price tool gives you a range before anyone visits.
Is the survey for swing doors in Perth and Kinross free?
Yes, for new operators and doorsets the survey is free and carries no obligation. The engineer looks at each door, its hinges, frame, locks, power and fire labels, and you receive a fixed, itemised written quote for the work. Each door is priced separately, so the work can be phased if needed.
Will the swing operator in Perth and Kinross work with our fire alarm?
It can. Fire doors that are held open must close automatically when the fire alarm operates, and the operator can be linked to the alarm to do this. Other doors can be set to open on alarm where the fire strategy needs it. Your alarm engineer usually makes the panel connection.
Will the building stay secure while the entrance is being changed?
We plan to keep the entrance usable or secure throughout. Where a door has to come out, the work is sequenced so the opening is closed up before the engineer leaves, or a temporary door or hoarding is arranged when a longer gap cannot be avoided. How this is handled for your site in Perth and Kinross is agreed before work starts.
What happens once the installation in Perth and Kinross is finished?
The engineer tests every function, including the safety sensors and the behaviour on power loss, and sets the door up with reference to BS EN 16005. You are shown how to use the controls and which simple checks to make, and you receive the handover documents, including the test record and any conformity paperwork that applies to the work.
Is a building warrant needed for a new automatic entrance in Perth and Kinross?
Often, yes. Most building work in Scotland needs a building warrant before it starts, and the non-domestic Technical Handbook sets out what an accessible entrance should provide, including a clear opening of at least 800 mm. We tell you at the survey if your job is likely to need one.