Coverage across the Lothians
We treat the Lothians as one service area for automatic door refurbishment, so a site on the edge of the area gets the same written pricing and the same standard of work as one in the busiest town centre. Specialist automatic door engineers working under our management carry out each visit. Choose from the 15 towns below, or contact us with any address.
Towns listed in the Lothians: Livingston, Musselburgh, Bathgate, Bonnyrigg, Penicuik, Broxburn, Mayfield, Linlithgow, Armadale, Dalkeith, Tranent, Whitburn, Dunbar, Prestonpans, Haddington.
What to think about for automatic door refurbishment in the Lothians
- Frames near the coast or busy roads can corrode faster. The survey checks fixings and the bottom of the frame, where water and grit tend to collect.
- Office blocks and business parks in the Lothians with several matching doors can refurbish them together for a consistent finish and a lower cost per door.
- Floors around the door in the Lothians may be worn or uneven. New floor guides and thresholds sometimes need small areas of making good, which the quote lists separately.
- Care settings in the Lothians benefit from level thresholds and smooth-running leaves that do not snag walking frames, trolleys or wheelchair footplates as people pass through.
- Glass and made-to-measure leaves are typically 2 to 4 weeks from order. Plan the work around that lead time, especially if a damaged leaf is temporarily boarded.
Automatic door refurbishment in the Lothians: guide prices
The site survey is free, including the measured drawing and a fixed, itemised written quote. Guide price: from £395 ex VAT.
| Item | Guide price | Notes |
|---|---|---|
| Running gear refresh: rollers, guides, brushes and seals | £395 – £895 | per door, ex VAT |
| Track overhaul | £395 – £895 | per door, ex VAT |
| Replacement glass leaf | from £495 | each, ex VAT; size and glass type on survey |
| Full refurbishment of a sliding door | £1,495 – £2,995 | running gear, seals, guides and one leaf, ex VAT |
Standards and rules in Scotland
Standards are not retrospective, so an older door does not become unlawful when a standard is updated; a site-specific risk assessment shows whether any upgrades are sensible. BS EN 16005 is the current standard for the safety in use of powered pedestrian doors, and BS 7036-0:2014 is the British code of practice for risk assessment and risk reduction used alongside it. Standards are not law in themselves, but they are the recognised benchmark for showing an automatic door is safe to use, and we set up, test and document doors with reference to them.
Whoever motorises a manual door, or builds an automatic door from separate parts, may take on the manufacturer’s legal duties for the finished door: a risk assessment, a technical file kept available for the authorities, a Declaration of Conformity, the conformity marking and instructions. You receive the Declaration of Conformity and the instructions at handover. In Great Britain a new or converted powered door must meet the Supply of Machinery (Safety) Regulations 2008 before it is first used, and can carry the UKCA or the CE marking.
Workplace law (the Workplace (Health, Safety and Welfare) Regulations 1992) expects powered doors to have suitable and effective features to stop them trapping anyone and, where needed for safety, to open by hand unless they open automatically if the power fails. Doors at work must also be kept in efficient working order under a suitable system of maintenance.
How it works
- Start with a short enquiry. Use the form, phone or email. Tell us whether the work is a new door, an upgrade or an opener for a home, and we arrange the next step for your site in the Lothians.
- Measured survey. The free survey confirms what will fit and what the entrance needs: opening width, door type, activation, safety sensors and behaviour on power loss or fire alarm, matched to how the building is used.
- Written price, no surprises. A fixed, itemised quote sets out the specification, the work involved, the expected lead time and the warranty terms. You can ask questions or change the specification before accepting it.
- Installed and commissioned. The door is installed with as little disruption as possible, then set up and tested for its hazard zones. Before leaving, the engineer explains the controls and hands over the documents for your records.
Book a free refurbishment survey in the Lothians. We will check the frame, leaves and running gear, then price each item separately on a fixed quote.
Automatic door refurbishment in the Lothians: questions
Can refurbishment in the Lothians help with draughts and heating costs?
New seals and brush strips, and leaves that close fully, reduce draughts through a closed door. For very exposed entrances, a second set of doors forming a draught lobby may also be worth considering, and we can price both so you can compare the likely benefit.
What will automatic door refurbishment in the Lothians cost?
Our guide starts from £395 excluding VAT (per door), the same guide price we use across the UK. The free site survey in the Lothians confirms the price as a fixed, itemised written quote, and the guide price tool gives you a range before anyone visits.
Can you refinish the frame of our door in the Lothians?
Yes. Aluminium frames can be cleaned, repaired and recoated on site to refresh their colour. Badly damaged sections may need replacing rather than refinishing. Refinishing is listed separately in the quote, so you can decide whether to include it now or leave it for a later phase.
Do you set up the door again after refurbishing it in the Lothians?
Yes. New running parts change how the leaves move, so speeds, sensor zones and obstacle detection are checked and reset before handover. You receive a record of the parts fitted and the test results to keep with the door's service history.
How do you make sure the door works for disabled visitors in the Lothians?
We look at who uses the entrance: wheelchair users, people with walking aids, parents with buggies and older visitors. That shapes the opening width, the opening speed, the hold-open time and where push pads or sensors go. Service providers and employers have duties to make reasonable adjustments under equality and accessibility law, and an automatic door is a common one.
What happens once the installation in the Lothians is finished?
The engineer tests every function, including the safety sensors and the behaviour on power loss, and sets the door up with reference to BS EN 16005. You are shown how to use the controls and which simple checks to make, and you receive the handover documents, including the test record and any conformity paperwork that applies to the work.
Who is responsible for automatic doors on escape routes in the Lothians?
The person responsible for fire safety under the Fire (Scotland) Act 2005 for those premises. Scottish guidance allows automatic doors on escape routes only where they fail safely to outward opening or have a monitored fail-safe system that opens them on power failure, sensor failure and fire alarm.