Coverage across the West Midlands
Not every part of the West Midlands is easy to reach, and some sites need planning around access, parking or opening hours. We take that into account when arranging access control for automatic doors, and the engineer, working under our management, arrives with what the job is likely to need. The towns below, 24 in all, each have their own page, but any address in the area can be covered.
Towns listed in the West Midlands: Birmingham, Coventry, Wolverhampton, Dudley, Walsall, Solihull, Sutton Coldfield, West Bromwich, Halesowen, Stourbridge, Smethwick, Willenhall, Tipton, Bloxwich, Oldbury, Wednesfield, Shirley, Bilston, Brierley Hill, Aldridge, Rowley Regis, Sedgley, Wednesbury, Kingswinford.
What to think about for access control for automatic doors in the West Midlands
- A video entry system needs a network or cable link between the door and wherever visitors are answered. Check the route before the survey, especially across car parks or between buildings.
- Residential blocks in the West Midlands usually have a managing agent or housing provider who sets the rules for fobs, visitors and fire alarm behaviour. Involve them early.
- If you already have an access control system, find out who installed and maintains it. Linking an automatic door is simpler when your security installer is part of the plan.
- Decide how the door should behave at each time of day before the survey. Opening hours, cleaning shifts, deliveries and weekend events all affect the schedule the door will follow.
- Think about lost cards and leavers. A system that lets you remove a card centrally is easier to run than a shared keypad code on a busy site.
Access control for automatic doors in the West Midlands: guide prices
The site survey is free, including the measured drawing and a fixed, itemised written quote. Guide price: from £795 ex VAT.
| Item | Guide price | Notes |
|---|---|---|
| Card or fob reader tied into the door | £795 – £2,495 | per door, ex VAT |
| Intercom or door entry tie-in | from £495 | priced on survey, ex VAT |
| Timed locking and night mode set-up | included with the above | programmed at commissioning |
| Electric lock added to an automatic door | on survey | depends on the door and the lock type |
Standards and rules in England
Under the Equality Act 2010, service providers and employers must make reasonable adjustments for disabled people, which can include altering a physical feature such as a heavy entrance door. Fitting an automatic door helps, but does not on its own guarantee those duties are met.
Building regulations guidance in England (Approved Document M, Volume 2) says a powered opening system should be used where a self-closing entrance door would need more than 30 N at the leading edge to open, or more than 22.5 N between 30° and 60°, and expects external doors used by the public in new buildings to give at least 1000 mm of effective clear width.
Whoever motorises a manual door, or builds an automatic door from separate parts, may take on the manufacturer’s legal duties for the finished door: a risk assessment, a technical file kept available for the authorities, a Declaration of Conformity, the conformity marking and instructions. You receive the Declaration of Conformity and the instructions at handover. In Great Britain a new or converted powered door must meet the Supply of Machinery (Safety) Regulations 2008 before it is first used, and can carry the UKCA or the CE marking.
How it works
- Tell us about the entrance. Send the address, a few photos and a rough size of the opening, and say how the door is used. That is enough for us to suggest options for access control for automatic doors and book a survey in the West Midlands.
- Free site survey. A specialist engineer working under our management measures the opening, checks the frame, floor, head height and power, and talks through how people use the entrance. There is no charge and no obligation.
- Fixed written quote. You receive a fixed, itemised written quote with the specification, lead time, payment stages and warranty terms. The price does not change unless the scope does, and any change is agreed in writing first.
- Installation and handover. The door is fitted on the agreed dates, then set up, tested and documented with reference to BS EN 16005. You are shown the controls and the simple checks to make, and receive the handover paperwork.
Ask for a fixed price on access control for an automatic door in the West Midlands. The quote covers the reader, lock, wiring, testing and handover records.
Access control for automatic doors in the West Midlands: questions
Can you service the door and access control in the West Midlands together?
We can service the door and test the link to the access control on each visit, leaving a written record. Visits are chargeable and priced in writing before anyone attends. If your security installer looks after the system, we can coordinate visits with them.
Can you give me a price for access control for automatic doors in the West Midlands?
Our guide starts from £795 excluding VAT (per door), the same guide price we use across the UK. The free site survey in the West Midlands confirms the price as a fixed, itemised written quote, and the guide price tool gives you a range before anyone visits.
Do you work with our security installer in the West Midlands?
Yes. Where a security installer already looks after your access control, we usually handle the door, the lock and the link to the operator, and they handle the reader, controller and permissions. The quote sets out who does what so nothing falls between the two.
Can you fit fob entry to a residential block in the West Midlands?
Yes. We can fit fob readers and video entry to an automatic communal door, set up so residents use fobs and visitors call the flat. Fire alarm and power-loss behaviour are agreed with the managing agent or housing provider before we commission the door.
What does the free site survey in the West Midlands involve?
An engineer working under our management visits the building, measures the opening, checks the frame, floor, head height and power supply, and looks at how people use the entrance. The survey is free and carries no obligation. Afterwards you receive a fixed, itemised written quote for access control for automatic doors, with drawings where the door type needs them.
How do you make sure the door works for disabled visitors in the West Midlands?
We look at who uses the entrance: wheelchair users, people with walking aids, parents with buggies and older visitors. That shapes the opening width, the opening speed, the hold-open time and where push pads or sensors go. Service providers and employers have duties to make reasonable adjustments under equality and accessibility law, and an automatic door is a common one.
Who is responsible for automatic doors on escape routes in the West Midlands?
Under the Regulatory Reform (Fire Safety) Order 2005 the responsible person for the premises must make sure escape routes work and fire safety equipment is maintained. Automatic doors on an escape route need fail-safe opening or break-out, set by the fire strategy.