Covering Gloucester and nearby
Requests for safety inspections and risk assessments in Gloucester are handled by us and passed to a specialist engineer working under our management. Coverage includes the GL1, GL2 and GL4 postcode districts: town-centre premises, business and retail sites, public buildings and residential streets alike.
Health centres, GP surgeries and clinics around Gloucester need doors that open gently and stay open long enough for patients using walking aids or wheelchairs. Low-energy operators, push pads and careful sensor set-up matter more here than sheer speed.
Nearby towns we also list for safety inspections and risk assessments (straight-line distance): Cheltenham (7.4 miles), Stroud (8.2 miles), Tewkesbury (9.4 miles), Ross-on-Wye (14.2 miles), Cirencester (15.4 miles), Malvern (17.3 miles).
What to think about for safety inspections and risk assessments in Gloucester
- Programme switches left in the wrong mode cause many incidents. The inspection checks the switch is secure, labelled and set correctly for each time of day.
- Schools and nurseries need particular care with finger traps at hinges and beside side screens, because children are more likely to put their hands into gaps.
- Insurers sometimes ask for inspection reports at renewal. Booking the inspection well before the renewal date gives you time to act on any high-priority findings first.
- Shared entrances in office blocks and business parks in Gloucester may serve several tenants. Agree who holds the report and who pays for upgrades before booking.
- Glass leaves need safety glazing and visible markings. Faded or missing manifestation is a common finding, and one of the quickest and cheapest to put right.
Safety inspections and risk assessments in Gloucester: guide prices
The visit price is agreed in writing before an engineer attends; parts and any further work are quoted before they are done. Guide price: typically £125 to £250 ex VAT.
| Item | Guide price | Notes |
|---|---|---|
| Safety inspection and risk assessment, existing door | £125 – £250 | per door, written report, ex VAT |
| Inspection added to a service visit | reduced | quoted with the service |
| Upgrades found by the inspection | quoted separately | see safety and compliance upgrades |
The inspection price is agreed in writing before the visit. Any upgrades the report recommends are quoted separately so you can plan them.
Standards and rules in England
Workplace law (the Workplace (Health, Safety and Welfare) Regulations 1992) expects powered doors to have suitable and effective features to stop them trapping anyone and, where needed for safety, to open by hand unless they open automatically if the power fails. Doors at work must also be kept in efficient working order under a suitable system of maintenance. HSE guidance on those regulations says the frequency of maintenance depends on the equipment and the manufacturer’s information.
BS EN 16005 is the current standard for the safety in use of powered pedestrian doors, and BS 7036-0:2014 is the British code of practice for risk assessment and risk reduction used alongside it. Standards are not law in themselves, but they are the recognised benchmark for showing an automatic door is safe to use, and we set up, test and document doors with reference to them. Standards are not retrospective, so an older door does not become unlawful when a standard is updated; a site-specific risk assessment shows whether any upgrades are sensible.
How it works
- Share the details. Send the address in Gloucester, the door type and make if you know it, and a description or video of the problem. For servicing, tell us how many doors there are and how busy each one is.
- Price confirmed in writing. We agree the visit price in writing before an engineer attends. Some straightforward repairs can be priced in full from photos and the make and model of the door.
- Diagnosis and repair. A specialist engineer attends on the agreed date, finds the cause, repairs or services the door, and tests its operation, sensors and safety functions with reference to BS EN 16005.
- Written record. Each visit ends with a written record for your files. Anything still outstanding, such as parts on order or recommended upgrades, is quoted before any further work is done.
Book an automatic door safety inspection in Gloucester. Tell us how many doors you have and how they are used, and we will confirm the price in writing.
Safety inspections and risk assessments in Gloucester: questions
What if a door in Gloucester is found to be unsafe?
The engineer explains the problem before leaving and may recommend switching the door to a safer mode until it is fixed. High-priority findings are flagged at the top of the report. We can quote the repair or upgrade straight away, or you can arrange it with another competent installer.
Can you give me a price for safety inspections and risk assessments in Gloucester?
Our guide is £125 to £250 excluding VAT (per door), the same guide prices we use across the UK. We agree the visit price in writing before an engineer attends in Gloucester, and quote any parts or further work before doing them. The price guide lists typical repair and service costs.
Can you inspect all the doors on our site in Gloucester in one visit?
Usually, yes. A whole-site inspection covers every automatic door in one visit and one report, with each door's findings ranked so you can compare priorities across the site. Larger sites may need more than one day, which we agree with you when the inspection is priced.
Do you carry out automatic door safety inspections in Gloucester?
Yes. We organise the inspection and issue the report, and the assessment in Gloucester is carried out by a specialist engineer under our management. Each door is assessed on site against BS EN 16005 hazard zones, its safety sensors are tested and you receive a written report with ranked findings. The inspection price is agreed in writing before the visit.
Do you leave a written record after each visit in Gloucester?
Yes. Every visit ends with a written record of what was checked, what was done and anything that still needs attention. For safety inspections you receive a report of the findings and a site-specific risk assessment. Keeping these on file is the usual way to show that a workplace door is maintained and in good working order.
How soon can an engineer get to Gloucester?
We do not promise response times. When you book, we give you the earliest date we can offer and confirm it once the price is agreed. If the door is unsafe in the meantime, it is usually best to switch it off or set it to a safe mode, put up a sign and keep people clear of it.
Do businesses in Gloucester have to fit automatic doors?
No law says every building must have automatic doors. Under the Equality Act 2010, service providers and employers must make reasonable adjustments for disabled people, and building regulations guidance in England calls for a powered door where an entrance door would otherwise be too heavy to open. An automatic door is often the simplest way to meet both.