From shops and surgeries to schools, care homes and private houses, any building in the BN7 postcode district can be covered for safety inspections and risk assessments. Specialist engineers working under our management carry out the work, and you deal with us as the contracting party from start to finish.
Libraries, health centres and council buildings in Lewes still need accessible entrances, whatever their size. A single automatic door with a push pad or touch-free switch is often enough to give everyone easy access.
Nearby towns we also list for safety inspections and risk assessments (straight-line distance): Peacehaven (5.7 miles), Brighton (7.2 miles), Uckfield (7.6 miles), Seaford (8.2 miles), Hove (8.2 miles), Burgess Hill (8.5 miles).
What to think about for safety inspections and risk assessments in Lewes
- Doors on escape routes must let people out safely during a fire or evacuation. The inspection checks break-out, power-failure opening or manual release, as the fire strategy requires.
- Retail entrances in Lewes with heavy footfall can have sensors knocked out of alignment over time. The inspection checks that detection still covers the full closing edge.
- Programme switches left in the wrong mode cause many incidents. The inspection checks the switch is secure, labelled and set correctly for each time of day.
- Care homes and hospitals in Lewes have users who move slowly or unpredictably. The inspection pays close attention to sensor coverage and door speeds where frail or confused people pass through.
- Shared entrances in office blocks and business parks in Lewes may serve several tenants. Agree who holds the report and who pays for upgrades before booking.
Safety inspections and risk assessments in Lewes: guide prices
The visit price is agreed in writing before an engineer attends; parts and any further work are quoted before they are done. Guide price: typically £125 to £250 ex VAT.
| Item | Guide price | Notes |
|---|---|---|
| Safety inspection and risk assessment, existing door | £125 – £250 | per door, written report, ex VAT |
| Inspection added to a service visit | reduced | quoted with the service |
| Upgrades found by the inspection | quoted separately | see safety and compliance upgrades |
The inspection price is agreed in writing before the visit. Any upgrades the report recommends are quoted separately so you can plan them.
Standards and rules in England
BS EN 16005 is the current standard for the safety in use of powered pedestrian doors, and BS 7036-0:2014 is the British code of practice for risk assessment and risk reduction used alongside it. Standards are not law in themselves, but they are the recognised benchmark for showing an automatic door is safe to use, and we set up, test and document doors with reference to them. Standards are not retrospective, so an older door does not become unlawful when a standard is updated; a site-specific risk assessment shows whether any upgrades are sensible.
No law sets a fixed service interval. We recommend that a trained engineer checks the safety functions at least once a year, with service intervals set by the manufacturer’s instructions and how heavily the door is used, and that someone on site carries out simple regular checks and keeps a record.
How it works
- Explain the problem. Whether the door is stuck, slow, noisy or due its next check, a short description and a few photos tell us which kind of visit to book for safety inspections and risk assessments and what to bring.
- Visit cost agreed. You get the visit price in writing before we book the engineer. There are no hidden extras: parts and further work are always quoted separately and in advance.
- Engineer on site. The engineer inspects the operator, sensors, tracks and leaves, carries out the repair or service, and runs the door through its safety tests before it goes back into use.
- Follow-up quoted. You are sent a record of the visit. If something else needs attention, we quote it in writing; for doors on a service plan, the next visit date is noted on the record.
Combine servicing and a safety inspection in Lewes in one visit. Contact us with your door details for a written price covering both.
Safety inspections and risk assessments in Lewes: questions
How often should doors in Lewes be risk assessed?
There is no set legal frequency. Most owners assess each door once, then repeat the assessment when the door is altered, when the people using it change or after an incident. In between, regular servicing keeps the safety functions checked, which in our view should happen at least once a year.
What do you charge for safety inspections and risk assessments in Lewes?
Our guide is £125 to £250 excluding VAT (per door), the same guide prices we use across the UK. We agree the visit price in writing before an engineer attends in Lewes, and quote any parts or further work before doing them. The price guide lists typical repair and service costs.
What if a door in Lewes is found to be unsafe?
The engineer explains the problem before leaving and may recommend switching the door to a safer mode until it is fixed. High-priority findings are flagged at the top of the report. We can quote the repair or upgrade straight away, or you can arrange it with another competent installer.
Can you inspect all the doors on our site in Lewes in one visit?
Usually, yes. A whole-site inspection covers every automatic door in one visit and one report, with each door's findings ranked so you can compare priorities across the site. Larger sites may need more than one day, which we agree with you when the inspection is priced.
How is the visit price set for work in Lewes?
We agree the visit price with you in writing before an engineer attends. It is based on the type of door, the work requested and the location. If parts or further work are needed once the engineer has found the cause, those are quoted before they are done, so the cost never moves without your agreement.
Can visits in Lewes be arranged outside working hours?
Yes, where the site needs it. Early-morning, evening and weekend visits can be arranged for shops, surgeries and offices that cannot lose their entrance during the day. Any difference in price for out-of-hours attendance is agreed in writing before the visit is booked, alongside the standard visit price.
Who is responsible for automatic doors on escape routes in Lewes?
Under the Regulatory Reform (Fire Safety) Order 2005 the responsible person for the premises must make sure escape routes work and fire safety equipment is maintained. Automatic doors on an escape route need fail-safe opening or break-out, set by the fire strategy.