Covering Washington and nearby
We do not keep premises in Washington. Instead, enquiries about revolving doors come to us, we agree the price in writing, and a specialist engineer working under our management travels to the address in the NE37 and NE38 postcode districts on a date that suits the site.
Health centres, GP surgeries and clinics around Washington need doors that open gently and stay open long enough for patients using walking aids or wheelchairs. Low-energy operators, push pads and careful sensor set-up matter more here than sheer speed.
Nearby towns we also list for revolving doors (straight-line distance): Chester-le-Street (3.7 miles), Houghton-le-Spring (4.6 miles), Hebburn (5.0 miles), Sunderland (5.4 miles), Gateshead (5.5 miles), Jarrow (5.7 miles).
What to think about for revolving doors in Washington
- Some visitors to buildings in Washington find revolving doors hard to use. A slow-speed button, clear signs and staff who can direct people to the pass door all help.
- Revolving doors with curved glass drum walls have longer lead times. Allow for them in any refurbishment programme across Tyne and Wear, and confirm dates before booking floor layers or shopfitters.
- Planned servicing is essential on revolving doors because wing edges, stop buttons and sensors protect people on every turn. Budget for regular visits from the start, with each visit priced in writing.
- Tall buildings in Washington can pull a strong draught through an open entrance. A revolving door controls this better than sliding doors, which is one reason office towers use them.
- Automatic revolving doors need power to the canopy and links to the fire alarm and access control. Plan cable routes before ceilings are closed in.
Revolving doors in Washington: guide prices
The site survey is free, including the measured drawing and a fixed, itemised written quote. Guide price: typically £29,995 to £59,995 ex VAT.
| Item | Guide price | Notes |
|---|---|---|
| Manual revolving door | from £14,995 | installed, ex VAT; priced on survey |
| Automatic revolving door, three or four wings, about 2.1 m diameter | £29,995 – £59,995 | installed, ex VAT |
| Large-diameter or high-capacity revolving doors | Priced on survey | often with a side swing or sliding door alongside |
| Side door for wheelchair users, prams and escape | see sliding and swing doors | usually needed alongside a revolving door |
Standards and rules in England
Building regulations guidance in England (Approved Document M, Volume 2) says a powered opening system should be used where a self-closing entrance door would need more than 30 N at the leading edge to open, or more than 22.5 N between 30° and 60°, and expects external doors used by the public in new buildings to give at least 1000 mm of effective clear width.
In Great Britain a new or converted powered door must meet the Supply of Machinery (Safety) Regulations 2008 before it is first used, and can carry the UKCA or the CE marking. Workplace law (the Workplace (Health, Safety and Welfare) Regulations 1992) expects powered doors to have suitable and effective features to stop them trapping anyone and, where needed for safety, to open by hand unless they open automatically if the power fails. Doors at work must also be kept in efficient working order under a suitable system of maintenance.
How it works
- Tell us about the entrance. Send the address, a few photos and a rough size of the opening, and say how the door is used. That is enough for us to suggest options for revolving doors and book a survey in Washington.
- Free site survey. A specialist engineer working under our management measures the opening, checks the frame, floor, head height and power, and talks through how people use the entrance. There is no charge and no obligation.
- Fixed written quote. You receive a fixed, itemised written quote with the specification, lead time, payment stages and warranty terms. The price does not change unless the scope does, and any change is agreed in writing first.
- Installation and handover. The door is fitted on the agreed dates, then set up, tested and documented with reference to BS EN 16005. You are shown the controls and the simple checks to make, and receive the handover paperwork.
Book a free survey in Washington to compare manual and automatic revolving doors, with drawings and one fixed, itemised quote.
Revolving doors in Washington: questions
Do you install revolving doors in Washington?
Yes. We arrange manual and automatic revolving doors, with their accessible pass doors, for buildings in Washington and across Tyne and Wear. Specialist automatic door engineers working under our management carry out the survey, installation and commissioning, and we are the contracting party throughout.
What price range should I expect for revolving doors in Washington?
Our guide is £29,995 to £59,995 excluding VAT (per automatic door), the same guide prices we use across the UK. The free site survey in Washington confirms the price as a fixed, itemised written quote, and the guide price tool gives you a range before anyone visits.
Do we need a pass door beside a revolving door in Washington?
In practice, yes. A revolving door is not accessible on its own, so an accessible powered swing or sliding door should be provided alongside for wheelchair users, pushchairs, deliveries and anyone who needs it. It also usually forms part of the escape strategy. We design and quote both together.
How long does a revolving door project in Washington take?
Revolving doors are typically 8 to 14 weeks from order, once drawings are approved. On site, an automatic revolving door usually takes several days, covering floor preparation, drum and canopy, wings, drive and commissioning. We agree the programme with you and plan how visitors will get in while the work is done.
What should I send before the survey in Washington?
A few photos of the door from inside and outside, rough measurements of the opening, the address and a note of how the entrance is used. If the door already has an operator, a photo of any label on it helps. With that, the engineer arrives prepared, the survey takes less of your time and we can put the quote for revolving doors together more easily.
What happens to the old door when a new one is fitted in Washington?
If the work replaces an existing door, frame or operator, removal and disposal are listed in the quote. The old door comes out only when the new one is ready to go in, so the opening is not left empty for longer than necessary. Making good to the surrounding wall, floor or ceiling is included where the quote says so.
Who is responsible for automatic doors on escape routes in Washington?
Under the Regulatory Reform (Fire Safety) Order 2005 the responsible person for the premises must make sure escape routes work and fire safety equipment is maintained. Automatic doors on an escape route need fail-safe opening or break-out, set by the fire strategy.