Covering Washington and nearby
For automatic entrance lobbies, coverage around Washington is set by postcode and includes the NE37 and NE38 postcode districts, as well as nearby addresses in Tyne and Wear. Specialist engineers working under our management attend each site, and the price is agreed in writing beforehand.
Care homes and supported living schemes are spread across Washington and the surrounding area, and their doors have to balance easy access with resident safety. Slow, gentle operation, hold-open devices linked to the fire alarm and controlled exits are typical requirements.
Nearby towns we also list for automatic entrance lobbies (straight-line distance): Chester-le-Street (3.7 miles), Houghton-le-Spring (4.6 miles), Hebburn (5.0 miles), Sunderland (5.4 miles), Gateshead (5.5 miles), Jarrow (5.7 miles).
What to think about for automatic entrance lobbies in Washington
- Surgeries and clinics in Washington need lobbies wide and deep enough for wheelchairs, mobility scooters and people with walking frames. Avoid interlocks at public entrances unless there is a strong security reason for them.
- Two operators mean two power supplies, or one supply sized for both. Check whether there is a suitable supply at ceiling height, as cable runs across a finished foyer add cost.
- Work on a lobby in Washington takes longer than a door swap. Ask for the programme in writing, including which entrance stays usable each day and any out-of-hours working.
- If the lobby is on an escape route, the fire strategy decides what both door sets do on alarm. Sequencing and interlocks must release so nothing stops people leaving.
- Listed buildings and conservation areas in Washington may limit changes to the frontage. An internal lobby behind the existing doors often keeps the street view unchanged, though consent may still be needed.
Automatic entrance lobbies in Washington: guide prices
The site survey is free, including the measured drawing and a fixed, itemised written quote. Guide price: typically £14,995 to £34,995 ex VAT.
| Item | Guide price | Notes |
|---|---|---|
| Draught lobby: two sets of automatic sliding doors and glazed screens | £14,995 – £34,995 | doors and screens, installed, ex VAT |
| Lobby with curtain walling or building work | Priced on survey | larger public-sector lobbies have cost £50,000 or more |
| Card or fob reader tied into the door | £795 – £2,495 | per door, ex VAT |
| Battery backup for power-cut operation | £395 – £695 | per door, ex VAT |
Lobby prices cover the doors and glazed screens. Building work, flooring, heating and curtain walling are priced on survey.
Standards and rules in England
In Great Britain a new or converted powered door must meet the Supply of Machinery (Safety) Regulations 2008 before it is first used, and can carry the UKCA or the CE marking. Workplace law (the Workplace (Health, Safety and Welfare) Regulations 1992) expects powered doors to have suitable and effective features to stop them trapping anyone and, where needed for safety, to open by hand unless they open automatically if the power fails. Doors at work must also be kept in efficient working order under a suitable system of maintenance.
Under the Equality Act 2010, service providers and employers must make reasonable adjustments for disabled people, which can include altering a physical feature such as a heavy entrance door. New entrances and some alterations count as building work, so check with building control before the work is ordered.
How it works
- Send photos and the address. A few pictures of the door from both sides, the address in Washington and a note of who uses the entrance help us understand the job before anyone visits the site.
- No-cost survey on site. We arrange a survey at a time that suits the building. The engineer records measurements, fixings and power, plus any constraints such as listed status, opening hours or access for deliveries.
- Itemised quote to approve. We price every element of the work on automatic entrance lobbies separately in a written quote that you can check, share and approve. Lead time and payment stages are stated, and nothing is ordered until you accept.
- Fit, test and hand over. On the agreed dates the engineer installs the equipment, commissions the operator and tests each safety function. You get a demonstration, the test record and any conformity paperwork that applies to the work.
Planning a refit or a new entrance in Washington? Get in touch early and we will quote the lobby as one package with the rest of the entrance.
Automatic entrance lobbies in Washington: questions
Can you look after the lobby doors in Washington after installation?
We can arrange planned servicing for both door sets, checking sequencing, safety sensors and alarm releases at each visit and leaving a written record. Servicing is charged per visit, and the price is confirmed in writing before an engineer comes out.
What is the guide price for automatic entrance lobbies in Washington?
Our guide is £14,995 to £34,995 excluding VAT (per lobby, doors and screens), the same guide prices we use across the UK. The free site survey in Washington confirms the price as a fixed, itemised written quote, and the guide price tool gives you a range before anyone visits.
Will our entrance in Washington have to close while the lobby is built?
Not for the whole job in most cases. We plan the order of work so one set of doors, or a temporary door, keeps the entrance usable, and agree any out-of-hours working in the quote. A short closure may be needed when the final set is commissioned.
Is a revolving door a better option than a lobby in Washington?
It can be where space is tight and traffic is steady, because a revolving door seals the entrance at every turn. A revolving door is not accessible on its own, though, so an accessible powered sliding or swing door is needed alongside it. We can price both at survey.
Can automatic doors be fitted to a listed building in Washington?
Often, yes, but listed building consent is normally needed for changes that affect the character of the building, inside or out. Slim operators, concealed fixings and automating the existing door can all reduce the visual impact. Speak to the conservation officer at the local planning authority early; we can provide drawings and specifications to help.
Will the building stay secure while the entrance is being changed?
We plan to keep the entrance usable or secure throughout. Where a door has to come out, the work is sequenced so the opening is closed up before the engineer leaves, or a temporary door or hoarding is arranged when a longer gap cannot be avoided. How this is handled for your site in Washington is agreed before work starts.
Which building regulations apply to a new automatic entrance in Washington?
In England the guidance is Approved Document M (Volume 2) for access, Approved Document B for fire safety and escape routes, and Approved Document K for glazing and powered doors. A new entrance can count as building work, so building control should be involved before it is ordered.