Covering Rugby and nearby
Sites across the CV21 and CV22 postcode districts are visited by specialist automatic door engineers working under our management. They travel to Rugby for fire door hold-open devices as bookings come in, so dates depend on the diary rather than a fixed local team, and we give you the earliest date we can offer when you book.
Health centres, GP surgeries and clinics around Rugby need doors that open gently and stay open long enough for patients using walking aids or wheelchairs. Low-energy operators, push pads and careful sensor set-up matter more here than sheer speed.
Nearby towns we also list for fire door hold-open devices (straight-line distance): Daventry (9.0 miles), Coventry (10.7 miles), Bedworth (11.4 miles), Leamington Spa (12.3 miles), Hinckley (12.5 miles), Nuneaton (13.5 miles).
What to think about for fire door hold-open devices in Rugby
- Fire doors on stairs and protected escape routes need particular care. The fire risk assessment may allow some of them to be held open and not others, so pricing is door by door.
- Listed buildings and conservation areas can make new cable runs difficult. Radio-triggered battery units avoid most wiring, although the transmitter still needs a connection at the alarm panel.
- Doors that open too far from a wall for a wall magnet can use a floor-mounted unit or a magnet on an extension arm. The survey measures where each door rests when open.
- Care homes in Rugby usually want bedroom doors that residents can open easily. Free-swing closers suit this, provided the evacuation strategy for the home supports them.
- Older buildings in Rugby may have fire doors that no longer close fully on their own. A hold-open device cannot fix that, so the survey checks closers, hinges and latches first.
Fire door hold-open devices in Rugby: guide prices
The site survey is free, including the measured drawing and a fixed, itemised written quote. Guide price: from £145 ex VAT.
| Item | Guide price | Notes |
|---|---|---|
| Battery acoustic hold-open unit | £145 – £295 | per door, fitted, ex VAT |
| Hard-wired hold-open magnet linked to the fire alarm | £245 – £595 | per door, ex VAT; alarm panel work extra |
| Free-swing door closer linked to the fire alarm | £395 – £895 | per door, fitted, ex VAT |
Which hold-open device is suitable depends on your fire risk assessment. Linking to the fire alarm may need work by your alarm engineer.
Standards and rules in England
Fire doors that are held open must close automatically when the fire alarm operates. Where hold-open devices can be used is decided by the fire risk assessment, which is the job of the responsible person under the Regulatory Reform (Fire Safety) Order 2005.
Hold-open devices and door release units linked to the fire alarm need regular testing as part of the building’s fire safety checks, and the results should be recorded.
How it works
- Describe what you need. Whether the job is fire door hold-open devices for a busy entrance or for a single internal door, a brief description and some photos let us understand it and plan a survey visit in Rugby.
- Free visit to the site. An engineer working under our management assesses the opening, the existing door and frame, the floor and the electrical supply, and notes any access, consent or timing issues to plan around.
- Your fixed quotation. The quote is fixed for the work it describes and lists each item, including any removal, making good and electrical work. It also states the lead time, the payment stages and the warranty terms.
- Fitting and sign-off. Work goes ahead on dates agreed with you. Once fitted, the door is adjusted and its safety functions are tested and recorded with reference to BS EN 16005, and you are shown how to use it.
Send us a list of the doors you want held open at your building in Rugby, plus any notes from your fire risk assessment, and we will arrange a survey at no cost.
Fire door hold-open devices in Rugby: questions
Will you test the hold-open devices before leaving our site in Rugby?
Yes. Every door is released from fully open and checked to close and latch. Where the alarm connection is complete, the doors are also tested with the alarm itself. You receive a schedule of the doors and devices fitted, ready to keep with your fire safety records and weekly alarm test log.
What do you charge for fire door hold-open devices in Rugby?
Our guide starts from £145 excluding VAT (per door), the same guide price we use across the UK. The free site survey in Rugby confirms the price as a fixed, itemised written quote, and the guide price tool gives you a range before anyone visits.
How soon can hold-open devices be fitted in Rugby?
Once the quote is accepted, supply is typically 1 to 3 weeks, and fitting a few devices on one floor usually takes a day. Larger jobs are planned in stages so doors are never left without protection. Your quote shows the expected programme, and fitting dates are agreed with you before work starts.
Are battery hold-open units a good choice for older buildings in Rugby?
Often they are. Radio and acoustic battery units avoid long cable runs, which helps in older or listed buildings and finished corridors. Acoustic units are only suitable where the fire risk assessment allows them and the alarm can be heard clearly at the door. Batteries need replacing at the interval the maker states.
Do you service doors in Rugby after installing them?
Yes. We recommend a trained engineer checks the safety functions at least once a year, with service intervals set by the manufacturer's instructions and how heavily the door is used; busy doors are often serviced more often. Servicing can follow on from the installation, with the price agreed in writing and a record left after every visit.
What power supply is needed for fire door hold-open devices in Rugby?
Most powered doors need a fused spur close to the operator, and some activation and access control devices also need a low-voltage link. The survey checks what is already there. If a new supply is required, the quote says whether we arrange it or your own electrician does, so nothing is left unclear on the day.
Who is responsible for automatic doors on escape routes in Rugby?
Under the Regulatory Reform (Fire Safety) Order 2005 the responsible person for the premises must make sure escape routes work and fire safety equipment is maintained. Automatic doors on an escape route need fail-safe opening or break-out, set by the fire strategy.