Covering Ware and nearby
We cover the whole of the SG12 postcode district, along with nearby towns in Hertfordshire. You book each visit for fire door hold-open devices directly with us, and a specialist automatic door engineer working under our management travels to your site on the agreed date.
Care homes in and around Ware often need automatic doors on corridors and day rooms as well as at the main entrance. Gentle operation, hold-open devices linked to the fire alarm and controlled exits help residents move about safely.
Nearby towns we also list for fire door hold-open devices (straight-line distance): Hertford (2.4 miles), Hoddesdon (3.5 miles), Harlow (6.4 miles), Cheshunt (7.6 miles), Welwyn Garden City (7.6 miles), Waltham Abbey (8.6 miles).
What to think about for fire door hold-open devices in Ware
- Hard-wired magnets need a power supply near each door. In buildings in Ware where that is awkward, battery units avoid running new cables along finished corridors.
- If the alarm panel has no spare outputs, a relay or an extra interface may be needed. Your alarm engineer can confirm this, and it is added to the quote once agreed.
- Older buildings in Ware may have fire doors that no longer close fully on their own. A hold-open device cannot fix that, so the survey checks closers, hinges and latches first.
- Busy office corridors suit wall magnets that hold doors right back against the wall, out of the way of people and trolleys, until the alarm releases them.
- Residential blocks often have communal corridor doors that residents prop open. Hold-open devices give the same convenience while letting the doors close when the alarm sounds.
Fire door hold-open devices in Ware: guide prices
The site survey is free, including the measured drawing and a fixed, itemised written quote. Guide price: from £145 ex VAT.
| Item | Guide price | Notes |
|---|---|---|
| Battery acoustic hold-open unit | £145 – £295 | per door, fitted, ex VAT |
| Hard-wired hold-open magnet linked to the fire alarm | £245 – £595 | per door, ex VAT; alarm panel work extra |
| Free-swing door closer linked to the fire alarm | £395 – £895 | per door, fitted, ex VAT |
Which hold-open device is suitable depends on your fire risk assessment. Linking to the fire alarm may need work by your alarm engineer.
Standards and rules in England
Workplace law (the Workplace (Health, Safety and Welfare) Regulations 1992) expects powered doors to have suitable and effective features to stop them trapping anyone and, where needed for safety, to open by hand unless they open automatically if the power fails. Doors at work must also be kept in efficient working order under a suitable system of maintenance.
Hold-open devices and door release units linked to the fire alarm need regular testing as part of the building’s fire safety checks, and the results should be recorded.
How it works
- Start with a short enquiry. Use the form, phone or email. Tell us whether the work is a new door, an upgrade or an opener for a home, and we arrange the next step for your site in Ware.
- Measured survey. The free survey confirms what will fit and what the entrance needs: opening width, door type, activation, safety sensors and behaviour on power loss or fire alarm, matched to how the building is used.
- Written price, no surprises. A fixed, itemised quote sets out the specification, the work involved, the expected lead time and the warranty terms. You can ask questions or change the specification before accepting it.
- Installed and commissioned. The door is installed with as little disruption as possible, then set up and tested for its hazard zones. Before leaving, the engineer explains the controls and hands over the documents for your records.
Send us a list of the doors you want held open at your building in Ware, plus any notes from your fire risk assessment, and we will arrange a survey at no cost.
Fire door hold-open devices in Ware: questions
Will you test the hold-open devices before leaving our site in Ware?
Yes. Every door is released from fully open and checked to close and latch. Where the alarm connection is complete, the doors are also tested with the alarm itself. You receive a schedule of the doors and devices fitted, ready to keep with your fire safety records and weekly alarm test log.
How much should I budget for fire door hold-open devices in Ware?
Our guide starts from £145 excluding VAT (per door), the same guide price we use across the UK. The free site survey in Ware confirms the price as a fixed, itemised written quote, and the guide price tool gives you a range before anyone visits.
Can you work with the fire alarm company that maintains our system in Ware?
Yes, and for wired devices we usually need to. The connection at the alarm panel is made by, or agreed with, the engineer who looks after your alarm. We share the device details with them and agree the visits, so the alarm and the doors can be tested together once the work is finished.
What will the survey in Ware look at?
The engineer checks that each door closes and latches from fully open, the condition of the closer and seals, where the door rests when open, nearby power supplies and the alarm panel or radio options. We also ask to see the relevant part of the fire risk assessment, so the quote covers only doors that can be held open.
How do you make sure the door works for disabled visitors in Ware?
We look at who uses the entrance: wheelchair users, people with walking aids, parents with buggies and older visitors. That shapes the opening width, the opening speed, the hold-open time and where push pads or sensors go. Service providers and employers have duties to make reasonable adjustments under equality and accessibility law, and an automatic door is a common one.
How are payments structured for work in Ware?
Payment stages are set out in the quote before you accept it. Larger or made-to-order jobs may involve a deposit and a balance on completion, while smaller jobs may be invoiced once the work is finished. Nothing is charged for the survey itself, and the terms you accept are the terms that apply.
Which building regulations apply to a new automatic entrance in Ware?
In England the guidance is Approved Document M (Volume 2) for access, Approved Document B for fire safety and escape routes, and Approved Document K for glazing and powered doors. A new entrance can count as building work, so building control should be involved before it is ordered.