Covering Long Eaton and nearby
Homes, businesses and public buildings throughout the NG10 postcode district can arrange fire door hold-open devices with us. We are the contracting party and organise every visit; the engineer, who works under our management, travels in to Long Eaton for the job rather than working from premises in town.
Older shopfronts are common in market towns, and some in Long Eaton may sit in a conservation area or a listed building. Changes to a frontage can need planning permission or listed building consent, so it is worth checking with the local planning authority before work is booked.
Nearby towns we also list for fire door hold-open devices (straight-line distance): Beeston (2.6 miles), Ilkeston (5.2 miles), Nottingham (6.3 miles), West Bridgford (6.5 miles), Eastwood (7.1 miles), Heanor (8.7 miles).
What to think about for fire door hold-open devices in Long Eaton
- Think about who tests the fire alarm each week at your building in Long Eaton. Adding a walk past the held-open doors to that test is the easiest way to confirm they release.
- If the alarm panel has no spare outputs, a relay or an extra interface may be needed. Your alarm engineer can confirm this, and it is added to the quote once agreed.
- Background noise matters for acoustic units. Kitchens, plant areas and busy receptions may be too loud for a unit that listens for the alarm, so a wired or radio device is often better there.
- Schools and colleges in Long Eaton may want hold-open devices fitted during the holidays so corridors are not disrupted in term time. Fitting can be planned around term dates.
- Doors that open too far from a wall for a wall magnet can use a floor-mounted unit or a magnet on an extension arm. The survey measures where each door rests when open.
Fire door hold-open devices in Long Eaton: guide prices
The site survey is free, including the measured drawing and a fixed, itemised written quote. Guide price: from £145 ex VAT.
| Item | Guide price | Notes |
|---|---|---|
| Battery acoustic hold-open unit | £145 – £295 | per door, fitted, ex VAT |
| Hard-wired hold-open magnet linked to the fire alarm | £245 – £595 | per door, ex VAT; alarm panel work extra |
| Free-swing door closer linked to the fire alarm | £395 – £895 | per door, fitted, ex VAT |
Which hold-open device is suitable depends on your fire risk assessment. Linking to the fire alarm may need work by your alarm engineer.
Standards and rules in England
Workplace law (the Workplace (Health, Safety and Welfare) Regulations 1992) expects powered doors to have suitable and effective features to stop them trapping anyone and, where needed for safety, to open by hand unless they open automatically if the power fails. Doors at work must also be kept in efficient working order under a suitable system of maintenance.
Fire doors that are held open must close automatically when the fire alarm operates. Where hold-open devices can be used is decided by the fire risk assessment, which is the job of the responsible person under the Regulatory Reform (Fire Safety) Order 2005.
How it works
- Tell us about the entrance. Send the address, a few photos and a rough size of the opening, and say how the door is used. That is enough for us to suggest options for fire door hold-open devices and book a survey in Long Eaton.
- Free site survey. A specialist engineer working under our management measures the opening, checks the frame, floor, head height and power, and talks through how people use the entrance. There is no charge and no obligation.
- Fixed written quote. You receive a fixed, itemised written quote with the specification, lead time, payment stages and warranty terms. The price does not change unless the scope does, and any change is agreed in writing first.
- Installation and handover. The door is fitted on the agreed dates, then set up, tested and documented with reference to BS EN 16005. You are shown the controls and the simple checks to make, and receive the handover paperwork.
For care homes, offices and schools in Long Eaton, we survey, quote and fit alarm-linked hold-open devices. Get in touch to arrange a time that suits your building.
Fire door hold-open devices in Long Eaton: questions
Are battery hold-open units a good choice for older buildings in Long Eaton?
Often they are. Radio and acoustic battery units avoid long cable runs, which helps in older or listed buildings and finished corridors. Acoustic units are only suitable where the fire risk assessment allows them and the alarm can be heard clearly at the door. Batteries need replacing at the interval the maker states.
How are prices worked out for fire door hold-open devices in Long Eaton?
Our guide starts from £145 excluding VAT (per door), the same guide price we use across the UK. The free site survey in Long Eaton confirms the price as a fixed, itemised written quote, and the guide price tool gives you a range before anyone visits.
Do care homes in Long Eaton use free-swing closers?
Many do. A free-swing closer lets residents open their bedroom door without pushing against a closer, and it still shuts the door when the fire alarm operates. Whether it suits each room depends on the home's fire risk assessment and evacuation strategy, which we read before recommending any device.
Which doors in my building in Long Eaton can be held open?
That is decided by the fire risk assessment for the building, not by the installer. Many corridor, lounge and office doors can be held open on a device that releases on the alarm, while some stair and escape route doors cannot. If the assessment is unclear, check with your assessor before we finalise the quote.
Will the building stay secure while the entrance is being changed?
We plan to keep the entrance usable or secure throughout. Where a door has to come out, the work is sequenced so the opening is closed up before the engineer leaves, or a temporary door or hoarding is arranged when a longer gap cannot be avoided. How this is handled for your site in Long Eaton is agreed before work starts.
How much disruption should we expect while the work is done in Long Eaton?
Most installations take one visit or a short series of visits, with dust and noise kept to the area around the door. The engineer screens off the work area, keeps a route in or out where possible and clears up before leaving. Larger entrances, lobbies or structural changes take longer, and the quote explains how that work is phased.
Which building regulations apply to a new automatic entrance in Long Eaton?
In England the guidance is Approved Document M (Volume 2) for access, Approved Document B for fire safety and escape routes, and Approved Document K for glazing and powered doors. A new entrance can count as building work, so building control should be involved before it is ordered.