Coverage across Devon
Wherever you are in Devon, we need the same three things to get started on access control for automatic doors: a short description of the door, a few photos if you have them, and the address. From there we agree the price in writing and book a specialist engineer working under our management. Every town listed below has a page of its own, 9 in total.
Towns listed in Devon: Plymouth, Exeter, Paignton, Torquay, Newton Abbot, Exmouth, Barnstaple, Bideford, Tiverton.
What to think about for access control for automatic doors in Devon
- Older automatic doors in Devon may not have inputs for access control. The survey checks this, and an older operator may need upgrading or replacing before readers can be linked.
- A video entry system needs a network or cable link between the door and wherever visitors are answered. Check the route before the survey, especially across car parks or between buildings.
- Think about lost cards and leavers. A system that lets you remove a card centrally is easier to run than a shared keypad code on a busy site.
- Healthcare sites in Devon often control access to wards and staff areas. Think about how visitors, porters and emergency teams will get through at every hour.
- Cable routes matter. Running cables between a reader, a controller and the operator through finished walls and ceilings can be a large share of the cost.
Access control for automatic doors in Devon: guide prices
The site survey is free, including the measured drawing and a fixed, itemised written quote. Guide price: from £795 ex VAT.
| Item | Guide price | Notes |
|---|---|---|
| Card or fob reader tied into the door | £795 – £2,495 | per door, ex VAT |
| Intercom or door entry tie-in | from £495 | priced on survey, ex VAT |
| Timed locking and night mode set-up | included with the above | programmed at commissioning |
| Electric lock added to an automatic door | on survey | depends on the door and the lock type |
Standards and rules in England
Under the Equality Act 2010, service providers and employers must make reasonable adjustments for disabled people, which can include altering a physical feature such as a heavy entrance door. Fitting an automatic door helps, but does not on its own guarantee those duties are met.
Building regulations guidance in England (Approved Document M, Volume 2) says a powered opening system should be used where a self-closing entrance door would need more than 30 N at the leading edge to open, or more than 22.5 N between 30° and 60°, and expects external doors used by the public in new buildings to give at least 1000 mm of effective clear width.
Whoever motorises a manual door, or builds an automatic door from separate parts, may take on the manufacturer’s legal duties for the finished door: a risk assessment, a technical file kept available for the authorities, a Declaration of Conformity, the conformity marking and instructions. You receive the Declaration of Conformity and the instructions at handover. In Great Britain a new or converted powered door must meet the Supply of Machinery (Safety) Regulations 2008 before it is first used, and can carry the UKCA or the CE marking.
How it works
- Describe what you need. Whether the job is access control for automatic doors for a busy entrance or for a single internal door, a brief description and some photos let us understand it and plan a survey visit in Devon.
- Free visit to the site. An engineer working under our management assesses the opening, the existing door and frame, the floor and the electrical supply, and notes any access, consent or timing issues to plan around.
- Your fixed quotation. The quote is fixed for the work it describes and lists each item, including any removal, making good and electrical work. It also states the lead time, the payment stages and the warranty terms.
- Fitting and sign-off. Work goes ahead on dates agreed with you. Once fitted, the door is adjusted and its safety functions are tested and recorded with reference to BS EN 16005, and you are shown how to use it.
From a single keypad to readers on every entrance, get a written quote for access control in Devon, starting with a free survey.
Access control for automatic doors in Devon: questions
Do you work with our security installer in Devon?
Yes. Where a security installer already looks after your access control, we usually handle the door, the lock and the link to the operator, and they handle the reader, controller and permissions. The quote sets out who does what so nothing falls between the two.
What is the guide price for access control for automatic doors in Devon?
Our guide starts from £795 excluding VAT (per door), the same guide price we use across the UK. The free site survey in Devon confirms the price as a fixed, itemised written quote, and the guide price tool gives you a range before anyone visits.
Will our door in Devon still release when the fire alarm sounds?
On an escape route, yes. Locks are wired to release on the fire alarm signal and, where the fire strategy requires it, the door opens and holds open. We test this with your fire alarm contractor at handover and record the result.
Can you service the door and access control in Devon together?
We can service the door and test the link to the access control on each visit, leaving a written record. Visits are chargeable and priced in writing before anyone attends. If your security installer looks after the system, we can coordinate visits with them.
Do you service doors in Devon after installing them?
Yes. We recommend a trained engineer checks the safety functions at least once a year, with service intervals set by the manufacturer's instructions and how heavily the door is used; busy doors are often serviced more often. Servicing can follow on from the installation, with the price agreed in writing and a record left after every visit.
What happens to the old door when a new one is fitted in Devon?
If the work replaces an existing door, frame or operator, removal and disposal are listed in the quote. The old door comes out only when the new one is ready to go in, so the opening is not left empty for longer than necessary. Making good to the surrounding wall, floor or ceiling is included where the quote says so.
Which building regulations apply to a new automatic entrance in Devon?
In England the guidance is Approved Document M (Volume 2) for access, Approved Document B for fire safety and escape routes, and Approved Document K for glazing and powered doors. A new entrance can count as building work, so building control should be involved before it is ordered.