Covering the City of London and nearby
Sites across the EC2V, EC3M, EC3V, EC4N, EC4R and EC4V postcode districts are visited by specialist automatic door engineers working under our management. They travel to the City of London for touch-free and push-button activation as bookings come in, so dates depend on the diary rather than a fixed local team, and we give you the earliest date we can offer when you book.
Transport hubs, large stations and busy retail streets in and around the City of London put automatic doors under near-constant use. Heavy-duty operators, break-out leaves on escape routes and regular servicing are typical requirements at entrances this busy.
Nearby towns we also list for touch-free and push-button activation (straight-line distance): Whitechapel (1.1 miles), Islington (1.7 miles), Westminster (2.2 miles), Peckham (2.8 miles), Camden Town (2.9 miles), Holloway (3.1 miles).
What to think about for touch-free and push-button activation in the City of London
- Clinics and surgeries in the City of London often want touch-free switches on every door patients use. Sealed switch faces that stand up to cleaning products are worth specifying.
- Wireless devices need batteries changing from time to time. Choose wired switches for the busiest public doors, and wireless where wiring would be difficult or would spoil a finished wall.
- Listed buildings in the City of London may restrict new fixings on historic walls. Wireless switches mounted on posts or glazing can avoid cutting into original fabric, and are easy to move later.
- Washrooms and accessible toilets in the City of London need the inside switch paired with a lock button and an emergency release, so the room can be used privately and safely.
- Look at where people approach the door from. A switch that can only be reached once someone is already at the door, or in the leaf's path, is in the wrong place.
Touch-free and push-button activation in the City of London: guide prices
The site survey is free, including the measured drawing and a fixed, itemised written quote. Guide price: from £145 ex VAT (£174 inc VAT).
| Item | Guide price | Notes |
|---|---|---|
| Touch-free switch or push pad, fitted | £145 – £395 | per switch, ex VAT; homes £174 – £474 inc VAT |
| Radio push-button kit | £195 – £495 | buttons and receiver, ex VAT; homes £234 – £594 inc VAT |
| Key switch or programme switch | £145 – £345 | fitted, ex VAT; homes £174 – £414 inc VAT |
| Replacement motion (activation) sensor | £195 – £495 | fitted, ex VAT; homes £234 – £594 inc VAT |
Standards and rules in England
Whoever motorises a manual door, or builds an automatic door from separate parts, may take on the manufacturer’s legal duties for the finished door: a risk assessment, a technical file kept available for the authorities, a Declaration of Conformity, the conformity marking and instructions. You receive the Declaration of Conformity and the instructions at handover. In Great Britain a new or converted powered door must meet the Supply of Machinery (Safety) Regulations 2008 before it is first used, and can carry the UKCA or the CE marking.
Under the Equality Act 2010, service providers and employers must make reasonable adjustments for disabled people, which can include altering a physical feature such as a heavy entrance door. Fitting an automatic door helps, but does not on its own guarantee those duties are met.
How it works
- Send photos and the address. A few pictures of the door from both sides, the address in the City of London and a note of who uses the entrance help us understand the job before anyone visits the site.
- No-cost survey on site. We arrange a survey at a time that suits the building. The engineer records measurements, fixings and power, plus any constraints such as listed status, opening hours or access for deliveries.
- Itemised quote to approve. We price every element of the work on touch-free and push-button activation separately in a written quote that you can check, share and approve. Lead time and payment stages are stated, and nothing is ordered until you accept.
- Fit, test and hand over. On the agreed dates the engineer installs the equipment, commissions the operator and tests each safety function. You get a demonstration, the test record and any conformity paperwork that applies to the work.
Book a free visit in the City of London and we will recommend activation for each side of each door, then send a written quote.
Touch-free and push-button activation in the City of London: questions
Can wave switches in the City of London be linked to our access control?
Yes. A wave switch can be set to work only after the access control system has released the lock, or to let people out freely from the inside while entry needs a card. We agree how it should behave and test it with your system at handover.
What do you charge for touch-free and push-button activation in the City of London?
Our guide starts from £145 excluding VAT (per switch fitted), the same guide price we use across the UK. For homes that is from £174 including VAT. The free site survey in the City of London confirms the price as a fixed, itemised written quote, and the guide price tool gives you a range before anyone visits.
Do touch-free switches work in cold or wet weather in the City of London?
Switches for outdoor use are sealed against rain and rated for outdoor temperatures. In exposed spots, a hood or a sheltered position helps. If a switch is outside, we specify one made for that rather than an indoor model, and check it is easy to see and reach in poor light.
Can you supply switches for several sites in the City of London?
Yes. We can survey several doors or buildings and quote each one separately, keeping switch types, heights and symbols the same across all your sites. That makes doors easier to find and use for visitors and staff. Larger orders can be phased site by site.
How much disruption should we expect while the work is done in the City of London?
Most installations take one visit or a short series of visits, with dust and noise kept to the area around the door. The engineer screens off the work area, keeps a route in or out where possible and clears up before leaving. Larger entrances, lobbies or structural changes take longer, and the quote explains how that work is phased.
What does the written quote for touch-free and push-button activation in the City of London include?
The quote lists each item separately: the door or equipment, installation, electrical connections where we provide them, removal of anything being replaced, testing and handover. It is a fixed price for the work described, so it does not change unless the scope changes, and any change is agreed with you in writing first.
Which building regulations apply to a new automatic entrance in the City of London?
In England the guidance is Approved Document M (Volume 2) for access, Approved Document B for fire safety and escape routes, and Approved Document K for glazing and powered doors. A new entrance can count as building work, so building control should be involved before it is ordered.