UK-wide · Free site survey and fixed written quote for new doors · Repair and service visits priced before we attend

Call 0800 088 6248

Automatic Door Installers

Telescopic sliding doors · Cheshire

Telescopic sliding doors in Nantwich

Telescopic doors stack two leaves behind each other, so an entrance in Nantwich can open wider than a standard sliding door would allow. Send us a photo and rough measurements, and we will book a free survey to confirm what is possible for your building.

Town
Nantwich
Area
Cheshire
Postcodes
CW5
Guide price
From £6,995 ex VAT
  • Free site survey for new doors
  • Fixed, itemised written quote
  • Set up with reference to BS EN 16005
  • England, Wales, Scotland and NI
  • Guide prices published

Covering Nantwich and nearby

Coverage for telescopic sliding doors runs across the CW5 postcode district and out into the surrounding parts of Cheshire. Wherever the building is, the arrangements stay the same: one contracting party, a written price before work, and a specialist engineer working under our management on site.

Older shopfronts are common in market towns, and some in Nantwich may sit in a conservation area or a listed building. Changes to a frontage can need planning permission or listed building consent, so it is worth checking with the local planning authority before work is booked.

Nearby towns we also list for telescopic sliding doors (straight-line distance): Crewe (3.8 miles), Sandbach (8.4 miles), Winsford (8.5 miles), Kidsgrove (11.8 miles), Newcastle-under-Lyme (12.8 miles), Northwich (13.1 miles).

What to think about for telescopic sliding doors in Nantwich

  • A telescopic header is deeper than a standard one. In older buildings in Nantwich with low ceilings or decorative fanlights, the survey checks whether the header can sit above the opening or needs to be recessed.
  • If the entrance is on an escape route, ask your fire risk assessor what the door must do before ordering. Break-out telescopic leaves have to be chosen at the start, because they cannot be added afterwards.
  • Power for the operator usually comes from a fused spur at the head of the door. Where the nearest supply is some distance away, plan for an electrician to run a new circuit before the fitting day.
  • Measure the widest thing that has to pass through, whether that is a hospital bed, a mobility scooter or a cage of stock. The clear opening of a telescopic door is chosen from that figure, not from the size of the old doorway.
  • Shop units in Nantwich that trade late or open early may want installation outside trading hours. Early starts and weekend work can usually be arranged and are shown as a separate line in the quote.

Telescopic sliding doors in Nantwich: guide prices

The site survey is free, including the measured drawing and a fixed, itemised written quote. Guide price: from £6,995 ex VAT.

ItemGuide priceNotes
Telescopic single-slide, two leaves£6,995 – £9,995installed, ex VAT
Telescopic bi-parting, four leaves£8,995 – £13,995installed, ex VAT
Very wide or full-height openingsPriced on surveymeasured and designed at the survey
Touch-free switch or push pad, fitted£145 – £395per switch, ex VAT
Card or fob reader tied into the door£795 – £2,495per door, ex VAT

Standards and rules in England

Building regulations guidance in England (Approved Document M, Volume 2) says a powered opening system should be used where a self-closing entrance door would need more than 30 N at the leading edge to open, or more than 22.5 N between 30° and 60°, and expects external doors used by the public in new buildings to give at least 1000 mm of effective clear width.

In Great Britain a new or converted powered door must meet the Supply of Machinery (Safety) Regulations 2008 before it is first used, and can carry the UKCA or the CE marking. Workplace law (the Workplace (Health, Safety and Welfare) Regulations 1992) expects powered doors to have suitable and effective features to stop them trapping anyone and, where needed for safety, to open by hand unless they open automatically if the power fails. Doors at work must also be kept in efficient working order under a suitable system of maintenance.

How it works

  1. Tell us about the entrance. Send the address, a few photos and a rough size of the opening, and say how the door is used. That is enough for us to suggest options for telescopic sliding doors and book a survey in Nantwich.
  2. Free site survey. A specialist engineer working under our management measures the opening, checks the frame, floor, head height and power, and talks through how people use the entrance. There is no charge and no obligation.
  3. Fixed written quote. You receive a fixed, itemised written quote with the specification, lead time, payment stages and warranty terms. The price does not change unless the scope does, and any change is agreed in writing first.
  4. Installation and handover. The door is fitted on the agreed dates, then set up, tested and documented with reference to BS EN 16005. You are shown the controls and the simple checks to make, and receive the handover paperwork.

For beds, trolleys or wheelchairs that need more room at your entrance in Nantwich, send us the details and we will plan a wider doorway.

Telescopic sliding doors in Nantwich: questions

Will a telescopic door in Nantwich work with our fire alarm?

It can. The operator can take a signal from the fire alarm panel so the door opens and stays open, or does whatever the fire strategy for the building requires. The panel connection is usually made by your alarm engineer, and the quote shows who is responsible for each part of the work.

Can you give me a price for telescopic sliding doors in Nantwich?

Our guide starts from £6,995 excluding VAT (per door set), the same guide price we use across the UK. The free site survey in Nantwich confirms the price as a fixed, itemised written quote, and the guide price tool gives you a range before anyone visits.

How much wider will our entrance in Nantwich be with telescopic doors?

As a rough guide, a telescopic door gives about two-thirds of its overall width as clear opening, against about half for a standard sliding door. On a typical shop or surgery entrance that can mean an extra 300 to 600 mm. The survey drawing for your building in Nantwich shows the exact clear width before you commit.

Can our existing sliding door in Nantwich be converted to telescopic?

Not usually by modifying the old door, because the header, tracks and leaves are different. It is normally replaced as a complete set within the same opening. The survey checks whether the existing structure and floor can take the new door, and the quote shows removal of the old one as a separate line.

How are payments structured for work in Nantwich?

Payment stages are set out in the quote before you accept it. Larger or made-to-order jobs may involve a deposit and a balance on completion, while smaller jobs may be invoiced once the work is finished. Nothing is charged for the survey itself, and the terms you accept are the terms that apply.

What power supply is needed for telescopic sliding doors in Nantwich?

Most powered doors need a fused spur close to the operator, and some activation and access control devices also need a low-voltage link. The survey checks what is already there. If a new supply is required, the quote says whether we arrange it or your own electrician does, so nothing is left unclear on the day.

Who is responsible for automatic doors on escape routes in Nantwich?

Under the Regulatory Reform (Fire Safety) Order 2005 the responsible person for the premises must make sure escape routes work and fire safety equipment is maintained. Automatic doors on an escape route need fail-safe opening or break-out, set by the fire strategy.

Next step

Telescopic sliding doors in Nantwich

Send the address, a photo if you have one and what the door needs to do. New installations get a free site survey and a fixed written quote; repairs and servicing are priced in writing before we attend.