Covering Winchester and nearby
Sites across the SO21, SO22 and SO23 postcode districts are visited by specialist automatic door engineers working under our management. They travel to Winchester for drive unit replacement as bookings come in, so dates depend on the diary rather than a fixed local team, and we give you the earliest date we can offer when you book.
In Winchester, automatic door needs often centre on the high street: independent shops, pharmacies, banks, cafés and estate agents. Frontages are often narrow, so the choice is usually between a compact sliding door, a folding door or a swing operator on the existing door.
Nearby towns we also list for drive unit replacement (straight-line distance): Chandler's Ford (6.6 miles), Eastleigh (6.9 miles), Romsey (9.5 miles), Hedge End (10.6 miles), Southampton (11.7 miles), Totton (12.6 miles).
What to think about for drive unit replacement in Winchester
- Busy retail entrances in Winchester may prefer the changeover after closing time or on a quiet trading day. Tell us your hours when you book the survey.
- Listed buildings and conservation areas in Winchester make it attractive to keep the existing frame. A new operator inside the existing header changes little that can be seen.
- Battery backup is easier to add with a new drive unit. It lets the door open or close safely in a power cut, which matters most on escape routes.
- If the door is on an escape route, the new drive unit must be set up to open, break out or be openable by hand, as the building's fire strategy requires.
- Hospitals and care homes in Winchester may need an alternative entrance during the changeover. Plan signs and step-free access for wheelchair users before work starts.
Drive unit replacement in Winchester: guide prices
The site survey is free, including the measured drawing and a fixed, itemised written quote. Guide price: typically £1,995 to £3,995 ex VAT.
| Item | Guide price | Notes |
|---|---|---|
| New drive unit on an existing automatic sliding door | £1,995 – £3,995 | existing leaves kept, installed, ex VAT |
| New operator on an existing automatic swing door | £1,795 – £3,995 | installed, ex VAT |
| Sensors replaced at the same time | £195 – £495 | per sensor, ex VAT |
Standards and rules in England
Workplace law (the Workplace (Health, Safety and Welfare) Regulations 1992) expects powered doors to have suitable and effective features to stop them trapping anyone and, where needed for safety, to open by hand unless they open automatically if the power fails. Doors at work must also be kept in efficient working order under a suitable system of maintenance.
Standards are not retrospective, so an older door does not become unlawful when a standard is updated; a site-specific risk assessment shows whether any upgrades are sensible. BS EN 16005 is the current standard for the safety in use of powered pedestrian doors, and BS 7036-0:2014 is the British code of practice for risk assessment and risk reduction used alongside it. Standards are not law in themselves, but they are the recognised benchmark for showing an automatic door is safe to use, and we set up, test and document doors with reference to them.
How it works
- Get in touch. Call, email or use the form with the address and what you have in mind. If you are not sure which type of door suits, describe the entrance and we will suggest the options worth considering.
- Survey and advice. The survey costs nothing and carries no obligation. The engineer checks the site and explains which options suit the entrance, the people using it and the budget, before anything is priced.
- Quote in writing. You receive a fixed, itemised quote for drive unit replacement in Winchester, covering equipment, installation, testing and handover, with the lead time and payment stages set out clearly.
- Install, test, explain. The engineer installs and commissions the door, tests the sensors, safety functions and emergency behaviour, and walks you through the controls. The handover pack records what was installed and tested.
Keep the frame, replace the drive. Arrange a free survey in Winchester and receive a fixed quote covering the new operator, sensors and paperwork.
Drive unit replacement in Winchester: questions
Can you fit a new operator to a door another company installed in Winchester?
Yes. We replace drive units on doors whoever fitted them. The survey identifies the existing header, leaves and track, and adapter plates usually let a new drive unit from one of the major European operator brands fit without changing the frame.
Is there a guide price for drive unit replacement in Winchester?
Our guide is £1,995 to £3,995 excluding VAT (per door), the same guide prices we use across the UK. The free site survey in Winchester confirms the price as a fixed, itemised written quote, and the guide price tool gives you a range before anyone visits.
How long will our entrance in Winchester be closed for the changeover?
A standard sliding door changeover typically takes a day, and a swing operator often less. The work can be scheduled early, after closing or at a weekend so it causes less disruption. Your quote shows the planned date and how long the entrance will be out of use.
What lead time should we expect in Winchester?
Once the quote is accepted, drive units are typically 2 to 4 weeks to arrive, depending on the length and weight rating needed. The changeover date is agreed with you as soon as the parts are confirmed, and it can be planned around your opening hours.
What does the free site survey in Winchester involve?
An engineer working under our management visits the building, measures the opening, checks the frame, floor, head height and power supply, and looks at how people use the entrance. The survey is free and carries no obligation. Afterwards you receive a fixed, itemised written quote for drive unit replacement, with drawings where the door type needs them.
What happens once the installation in Winchester is finished?
The engineer tests every function, including the safety sensors and the behaviour on power loss, and sets the door up with reference to BS EN 16005. You are shown how to use the controls and which simple checks to make, and you receive the handover documents, including the test record and any conformity paperwork that applies to the work.
Who is responsible for automatic doors on escape routes in Winchester?
Under the Regulatory Reform (Fire Safety) Order 2005 the responsible person for the premises must make sure escape routes work and fire safety equipment is maintained. Automatic doors on an escape route need fail-safe opening or break-out, set by the fire strategy.