Covering Washington and nearby
Sites across the NE37 and NE38 postcode districts are visited by specialist automatic door engineers working under our management. They travel to Washington for fire door hold-open devices as bookings come in, so dates depend on the diary rather than a fixed local team, and we give you the earliest date we can offer when you book.
Town-centre buildings in Washington range from modern units to older shopfronts. Older frontages can have uneven floors, limited head height and timber frames that need checking before an operator is fitted or adjusted, and the engineer looks at these on site.
Nearby towns we also list for fire door hold-open devices (straight-line distance): Chester-le-Street (3.7 miles), Houghton-le-Spring (4.6 miles), Hebburn (5.0 miles), Sunderland (5.4 miles), Gateshead (5.5 miles), Jarrow (5.7 miles).
What to think about for fire door hold-open devices in Washington
- If the alarm panel has no spare outputs, a relay or an extra interface may be needed. Your alarm engineer can confirm this, and it is added to the quote once agreed.
- Older buildings in Washington may have fire doors that no longer close fully on their own. A hold-open device cannot fix that, so the survey checks closers, hinges and latches first.
- Fire doors on stairs and protected escape routes need particular care. The fire risk assessment may allow some of them to be held open and not others, so pricing is door by door.
- Schools and colleges in Washington may want hold-open devices fitted during the holidays so corridors are not disrupted in term time. Fitting can be planned around term dates.
- Doors that open too far from a wall for a wall magnet can use a floor-mounted unit or a magnet on an extension arm. The survey measures where each door rests when open.
Fire door hold-open devices in Washington: guide prices
The site survey is free, including the measured drawing and a fixed, itemised written quote. Guide price: from £145 ex VAT.
| Item | Guide price | Notes |
|---|---|---|
| Battery acoustic hold-open unit | £145 – £295 | per door, fitted, ex VAT |
| Hard-wired hold-open magnet linked to the fire alarm | £245 – £595 | per door, ex VAT; alarm panel work extra |
| Free-swing door closer linked to the fire alarm | £395 – £895 | per door, fitted, ex VAT |
Which hold-open device is suitable depends on your fire risk assessment. Linking to the fire alarm may need work by your alarm engineer.
Standards and rules in England
Fire doors that are held open must close automatically when the fire alarm operates. Where hold-open devices can be used is decided by the fire risk assessment, which is the job of the responsible person under the Regulatory Reform (Fire Safety) Order 2005.
Workplace law (the Workplace (Health, Safety and Welfare) Regulations 1992) expects powered doors to have suitable and effective features to stop them trapping anyone and, where needed for safety, to open by hand unless they open automatically if the power fails. Doors at work must also be kept in efficient working order under a suitable system of maintenance.
How it works
- Start with a short enquiry. Use the form, phone or email. Tell us whether the work is a new door, an upgrade or an opener for a home, and we arrange the next step for your site in Washington.
- Measured survey. The free survey confirms what will fit and what the entrance needs: opening width, door type, activation, safety sensors and behaviour on power loss or fire alarm, matched to how the building is used.
- Written price, no surprises. A fixed, itemised quote sets out the specification, the work involved, the expected lead time and the warranty terms. You can ask questions or change the specification before accepting it.
- Installed and commissioned. The door is installed with as little disruption as possible, then set up and tested for its hazard zones. Before leaving, the engineer explains the controls and hands over the documents for your records.
For care homes, offices and schools in Washington, we survey, quote and fit alarm-linked hold-open devices. Get in touch to arrange a time that suits your building.
Fire door hold-open devices in Washington: questions
Will you test the hold-open devices before leaving our site in Washington?
Yes. Every door is released from fully open and checked to close and latch. Where the alarm connection is complete, the doors are also tested with the alarm itself. You receive a schedule of the doors and devices fitted, ready to keep with your fire safety records and weekly alarm test log.
What is the guide price for fire door hold-open devices in Washington?
Our guide starts from £145 excluding VAT (per door), the same guide price we use across the UK. The free site survey in Washington confirms the price as a fixed, itemised written quote, and the guide price tool gives you a range before anyone visits.
What will the survey in Washington look at?
The engineer checks that each door closes and latches from fully open, the condition of the closer and seals, where the door rests when open, nearby power supplies and the alarm panel or radio options. We also ask to see the relevant part of the fire risk assessment, so the quote covers only doors that can be held open.
How soon can hold-open devices be fitted in Washington?
Once the quote is accepted, supply is typically 1 to 3 weeks, and fitting a few devices on one floor usually takes a day. Larger jobs are planned in stages so doors are never left without protection. Your quote shows the expected programme, and fitting dates are agreed with you before work starts.
What should I send before the survey in Washington?
A few photos of the door from inside and outside, rough measurements of the opening, the address and a note of how the entrance is used. If the door already has an operator, a photo of any label on it helps. With that, the engineer arrives prepared, the survey takes less of your time and we can put the quote for fire door hold-open devices together more easily.
Can installation in Washington happen outside opening hours?
Yes. Many shops, surgeries and offices prefer work early in the morning, in the evening or at weekends, when the entrance is quietest. Tell us your constraints when you enquire and they are built into the plan. Any extra cost for out-of-hours work is shown in the written quote rather than added afterwards.
Which building regulations apply to a new automatic entrance in Washington?
In England the guidance is Approved Document M (Volume 2) for access, Approved Document B for fire safety and escape routes, and Approved Document K for glazing and powered doors. A new entrance can count as building work, so building control should be involved before it is ordered.