Covering Redcar and nearby
Our coverage of Redcar takes in the TS10 postcode district and the neighbouring parts of North Yorkshire. If your address sits close to a boundary, it is still covered: send the postcode with your enquiry about fire door hold-open devices and we will confirm the arrangements and the price in writing.
Parking on a busy high street can be tight. When work is booked in Redcar, the engineer's arrival is planned around loading restrictions, any market days and opening hours, so the visit causes as little disruption as possible.
Nearby towns we also list for fire door hold-open devices (straight-line distance): Middlesbrough (7.5 miles), Hartlepool (7.7 miles), Billingham (9.4 miles), Stockton-on-Tees (10.9 miles), Thornaby-on-Tees (11.2 miles), Yarm (14.3 miles).
What to think about for fire door hold-open devices in Redcar
- Busy office corridors suit wall magnets that hold doors right back against the wall, out of the way of people and trolleys, until the alarm releases them.
- Residential blocks often have communal corridor doors that residents prop open. Hold-open devices give the same convenience while letting the doors close when the alarm sounds.
- Listed buildings and conservation areas can make new cable runs difficult. Radio-triggered battery units avoid most wiring, although the transmitter still needs a connection at the alarm panel.
- Doors that open too far from a wall for a wall magnet can use a floor-mounted unit or a magnet on an extension arm. The survey measures where each door rests when open.
- Hard-wired magnets need a power supply near each door. In buildings in Redcar where that is awkward, battery units avoid running new cables along finished corridors.
Fire door hold-open devices in Redcar: guide prices
The site survey is free, including the measured drawing and a fixed, itemised written quote. Guide price: from £145 ex VAT.
| Item | Guide price | Notes |
|---|---|---|
| Battery acoustic hold-open unit | £145 – £295 | per door, fitted, ex VAT |
| Hard-wired hold-open magnet linked to the fire alarm | £245 – £595 | per door, ex VAT; alarm panel work extra |
| Free-swing door closer linked to the fire alarm | £395 – £895 | per door, fitted, ex VAT |
Which hold-open device is suitable depends on your fire risk assessment. Linking to the fire alarm may need work by your alarm engineer.
Standards and rules in England
Workplace law (the Workplace (Health, Safety and Welfare) Regulations 1992) expects powered doors to have suitable and effective features to stop them trapping anyone and, where needed for safety, to open by hand unless they open automatically if the power fails. Doors at work must also be kept in efficient working order under a suitable system of maintenance.
Fire doors that are held open must close automatically when the fire alarm operates. Where hold-open devices can be used is decided by the fire risk assessment, which is the job of the responsible person under the Regulatory Reform (Fire Safety) Order 2005.
How it works
- Get in touch. Call, email or use the form with the address and what you have in mind. If you are not sure which type of door suits, describe the entrance and we will suggest the options worth considering.
- Survey and advice. The survey costs nothing and carries no obligation. The engineer checks the site and explains which options suit the entrance, the people using it and the budget, before anything is priced.
- Quote in writing. You receive a fixed, itemised quote for fire door hold-open devices in Redcar, covering equipment, installation, testing and handover, with the lead time and payment stages set out clearly.
- Install, test, explain. The engineer installs and commissions the door, tests the sensors, safety functions and emergency behaviour, and walks you through the controls. The handover pack records what was installed and tested.
Arrange your free hold-open device survey in Redcar today and receive a written quote with a fixed price. Nothing is fitted until you have accepted it.
Fire door hold-open devices in Redcar: questions
Will you test the hold-open devices before leaving our site in Redcar?
Yes. Every door is released from fully open and checked to close and latch. Where the alarm connection is complete, the doors are also tested with the alarm itself. You receive a schedule of the doors and devices fitted, ready to keep with your fire safety records and weekly alarm test log.
Can you give me a price for fire door hold-open devices in Redcar?
Our guide starts from £145 excluding VAT (per door), the same guide price we use across the UK. The free site survey in Redcar confirms the price as a fixed, itemised written quote, and the guide price tool gives you a range before anyone visits.
Which doors in my building in Redcar can be held open?
That is decided by the fire risk assessment for the building, not by the installer. Many corridor, lounge and office doors can be held open on a device that releases on the alarm, while some stair and escape route doors cannot. If the assessment is unclear, check with your assessor before we finalise the quote.
Can you work with the fire alarm company that maintains our system in Redcar?
Yes, and for wired devices we usually need to. The connection at the alarm panel is made by, or agreed with, the engineer who looks after your alarm. We share the device details with them and agree the visits, so the alarm and the doors can be tested together once the work is finished.
What is the lead time for fire door hold-open devices in Redcar?
Lead times depend on the door type and what has to be made to order. As a guide, operators and accessible door kits are typically two to four weeks from order, and complete sliding entrances typically four to eight weeks from drawing approval. Curved, revolving and hermetic doors usually take longer. The expected lead time is stated in your quote.
Can automatic doors be fitted to a listed building in Redcar?
Often, yes, but listed building consent is normally needed for changes that affect the character of the building, inside or out. Slim operators, concealed fixings and automating the existing door can all reduce the visual impact. Speak to the conservation officer at the local planning authority early; we can provide drawings and specifications to help.
Who is responsible for automatic doors on escape routes in Redcar?
Under the Regulatory Reform (Fire Safety) Order 2005 the responsible person for the premises must make sure escape routes work and fire safety equipment is maintained. Automatic doors on an escape route need fail-safe opening or break-out, set by the fire strategy.