Covering Inverness and nearby
We cover the whole of the IV1, IV2 and IV3 postcode districts, along with nearby towns in the Highlands. You book each visit for fire door hold-open devices directly with us, and a specialist automatic door engineer working under our management travels to your site on the agreed date.
Small offices, community centres and village halls around Inverness tend to have one main entrance, often used by visitors who need level access without steps. Automating the existing door, rather than replacing it, is frequently the most practical and affordable route.
Nearby towns we also list for fire door hold-open devices (straight-line distance): Nairn (14.6 miles), Forres (24.1 miles).
What to think about for fire door hold-open devices in Inverness
- If the alarm panel has no spare outputs, a relay or an extra interface may be needed. Your alarm engineer can confirm this, and it is added to the quote once agreed.
- Busy office corridors suit wall magnets that hold doors right back against the wall, out of the way of people and trolleys, until the alarm releases them.
- Care homes in Inverness usually want bedroom doors that residents can open easily. Free-swing closers suit this, provided the evacuation strategy for the home supports them.
- Older buildings in Inverness may have fire doors that no longer close fully on their own. A hold-open device cannot fix that, so the survey checks closers, hinges and latches first.
- Think about who tests the fire alarm each week at your building in Inverness. Adding a walk past the held-open doors to that test is the easiest way to confirm they release.
Fire door hold-open devices in Inverness: guide prices
The site survey is free, including the measured drawing and a fixed, itemised written quote. Guide price: from £145 ex VAT.
| Item | Guide price | Notes |
|---|---|---|
| Battery acoustic hold-open unit | £145 – £295 | per door, fitted, ex VAT |
| Hard-wired hold-open magnet linked to the fire alarm | £245 – £595 | per door, ex VAT; alarm panel work extra |
| Free-swing door closer linked to the fire alarm | £395 – £895 | per door, fitted, ex VAT |
Which hold-open device is suitable depends on your fire risk assessment. Linking to the fire alarm may need work by your alarm engineer.
Standards and rules in Scotland
Fire doors that are held open must close automatically when the fire alarm operates. Where hold-open devices can be used is decided by the fire risk assessment, which is the job of the person responsible for fire safety under the Fire (Scotland) Act 2005.
Workplace law (the Workplace (Health, Safety and Welfare) Regulations 1992) expects powered doors to have suitable and effective features to stop them trapping anyone and, where needed for safety, to open by hand unless they open automatically if the power fails. Doors at work must also be kept in efficient working order under a suitable system of maintenance.
How it works
- Get in touch. Call, email or use the form with the address and what you have in mind. If you are not sure which type of door suits, describe the entrance and we will suggest the options worth considering.
- Survey and advice. The survey costs nothing and carries no obligation. The engineer checks the site and explains which options suit the entrance, the people using it and the budget, before anything is priced.
- Quote in writing. You receive a fixed, itemised quote for fire door hold-open devices in Inverness, covering equipment, installation, testing and handover, with the lead time and payment stages set out clearly.
- Install, test, explain. The engineer installs and commissions the door, tests the sensors, safety functions and emergency behaviour, and walks you through the controls. The handover pack records what was installed and tested.
Send us a list of the doors you want held open at your building in Inverness, plus any notes from your fire risk assessment, and we will arrange a survey at no cost.
Fire door hold-open devices in Inverness: questions
Are battery hold-open units a good choice for older buildings in Inverness?
Often they are. Radio and acoustic battery units avoid long cable runs, which helps in older or listed buildings and finished corridors. Acoustic units are only suitable where the fire risk assessment allows them and the alarm can be heard clearly at the door. Batteries need replacing at the interval the maker states.
What will fire door hold-open devices in Inverness cost?
Our guide starts from £145 excluding VAT (per door), the same guide price we use across the UK. The free site survey in Inverness confirms the price as a fixed, itemised written quote, and the guide price tool gives you a range before anyone visits.
Will you test the hold-open devices before leaving our site in Inverness?
Yes. Every door is released from fully open and checked to close and latch. Where the alarm connection is complete, the doors are also tested with the alarm itself. You receive a schedule of the doors and devices fitted, ready to keep with your fire safety records and weekly alarm test log.
Can you work with the fire alarm company that maintains our system in Inverness?
Yes, and for wired devices we usually need to. The connection at the alarm panel is made by, or agreed with, the engineer who looks after your alarm. We share the device details with them and agree the visits, so the alarm and the doors can be tested together once the work is finished.
How much disruption should we expect while the work is done in Inverness?
Most installations take one visit or a short series of visits, with dust and noise kept to the area around the door. The engineer screens off the work area, keeps a route in or out where possible and clears up before leaving. Larger entrances, lobbies or structural changes take longer, and the quote explains how that work is phased.
What is the lead time for fire door hold-open devices in Inverness?
Lead times depend on the door type and what has to be made to order. As a guide, operators and accessible door kits are typically two to four weeks from order, and complete sliding entrances typically four to eight weeks from drawing approval. Curved, revolving and hermetic doors usually take longer. The expected lead time is stated in your quote.
Do businesses in Inverness have to fit automatic doors?
No law requires automatic doors everywhere. Under the Equality Act 2010 service providers and employers must make reasonable adjustments for disabled people, and Scottish guidance says powered doors improve accessibility at entrances. An automatic door is often the practical answer.