Covering Aberystwyth and nearby
Sites across the SY23 postcode district are visited by specialist automatic door engineers working under our management. They travel to Aberystwyth for fire door hold-open devices as bookings come in, so dates depend on the diary rather than a fixed local team, and we give you the earliest date we can offer when you book.
Care homes in and around Aberystwyth often need automatic doors on corridors and day rooms as well as at the main entrance. Gentle operation, hold-open devices linked to the fire alarm and controlled exits help residents move about safely.
What to think about for fire door hold-open devices in Aberystwyth
- Background noise matters for acoustic units. Kitchens, plant areas and busy receptions may be too loud for a unit that listens for the alarm, so a wired or radio device is often better there.
- Think about who tests the fire alarm each week at your building in Aberystwyth. Adding a walk past the held-open doors to that test is the easiest way to confirm they release.
- Doors that open too far from a wall for a wall magnet can use a floor-mounted unit or a magnet on an extension arm. The survey measures where each door rests when open.
- If the alarm panel has no spare outputs, a relay or an extra interface may be needed. Your alarm engineer can confirm this, and it is added to the quote once agreed.
- Older buildings in Aberystwyth may have fire doors that no longer close fully on their own. A hold-open device cannot fix that, so the survey checks closers, hinges and latches first.
Fire door hold-open devices in Aberystwyth: guide prices
The site survey is free, including the measured drawing and a fixed, itemised written quote. Guide price: from £145 ex VAT.
| Item | Guide price | Notes |
|---|---|---|
| Battery acoustic hold-open unit | £145 – £295 | per door, fitted, ex VAT |
| Hard-wired hold-open magnet linked to the fire alarm | £245 – £595 | per door, ex VAT; alarm panel work extra |
| Free-swing door closer linked to the fire alarm | £395 – £895 | per door, fitted, ex VAT |
Which hold-open device is suitable depends on your fire risk assessment. Linking to the fire alarm may need work by your alarm engineer.
Standards and rules in Wales
Fire doors that are held open must close automatically when the fire alarm operates. Where hold-open devices can be used is decided by the fire risk assessment, which is the job of the responsible person under the Regulatory Reform (Fire Safety) Order 2005.
Workplace law (the Workplace (Health, Safety and Welfare) Regulations 1992) expects powered doors to have suitable and effective features to stop them trapping anyone and, where needed for safety, to open by hand unless they open automatically if the power fails. Doors at work must also be kept in efficient working order under a suitable system of maintenance.
How it works
- Get in touch. Call, email or use the form with the address and what you have in mind. If you are not sure which type of door suits, describe the entrance and we will suggest the options worth considering.
- Survey and advice. The survey costs nothing and carries no obligation. The engineer checks the site and explains which options suit the entrance, the people using it and the budget, before anything is priced.
- Quote in writing. You receive a fixed, itemised quote for fire door hold-open devices in Aberystwyth, covering equipment, installation, testing and handover, with the lead time and payment stages set out clearly.
- Install, test, explain. The engineer installs and commissions the door, tests the sensors, safety functions and emergency behaviour, and walks you through the controls. The handover pack records what was installed and tested.
Ready to stop wedging fire doors open in Aberystwyth? Book a free survey and get a fixed, itemised quote for every door that needs a hold-open device.
Fire door hold-open devices in Aberystwyth: questions
Which doors in my building in Aberystwyth can be held open?
That is decided by the fire risk assessment for the building, not by the installer. Many corridor, lounge and office doors can be held open on a device that releases on the alarm, while some stair and escape route doors cannot. If the assessment is unclear, check with your assessor before we finalise the quote.
What will fire door hold-open devices in Aberystwyth cost?
Our guide starts from £145 excluding VAT (per door), the same guide price we use across the UK. The free site survey in Aberystwyth confirms the price as a fixed, itemised written quote, and the guide price tool gives you a range before anyone visits.
Are battery hold-open units a good choice for older buildings in Aberystwyth?
Often they are. Radio and acoustic battery units avoid long cable runs, which helps in older or listed buildings and finished corridors. Acoustic units are only suitable where the fire risk assessment allows them and the alarm can be heard clearly at the door. Batteries need replacing at the interval the maker states.
Do you fit fire door hold-open devices in Aberystwyth?
Yes. We arrange surveys and installations in Aberystwyth through specialist engineers working under our management. They look at each door, its closer and the alarm system, recommend a device for each door and we send a fixed, itemised quote. The survey costs you nothing, and you are under no obligation to accept the quote.
How are payments structured for work in Aberystwyth?
Payment stages are set out in the quote before you accept it. Larger or made-to-order jobs may involve a deposit and a balance on completion, while smaller jobs may be invoiced once the work is finished. Nothing is charged for the survey itself, and the terms you accept are the terms that apply.
What power supply is needed for fire door hold-open devices in Aberystwyth?
Most powered doors need a fused spur close to the operator, and some activation and access control devices also need a low-voltage link. The survey checks what is already there. If a new supply is required, the quote says whether we arrange it or your own electrician does, so nothing is left unclear on the day.
Who is responsible for automatic doors on escape routes in Aberystwyth?
The responsible person under the Regulatory Reform (Fire Safety) Order 2005. Automatic doors on an escape route need fail-safe opening or break-out, and sliding or revolving doors must not be used for exits specifically intended as emergency exits.