Covering Dunbar and nearby
Engineers working under our management travel to addresses across the EH42 postcode district for automatic entrance lobbies. There is no depot or showroom in Dunbar; you arrange everything with us by phone, email or the form on this page, and we confirm the price in writing first.
GP surgeries, dental practices and pharmacies in Dunbar often serve older patients and people with limited mobility. A low-energy swing operator, or a gentle sliding door with a push pad, can make a real difference at entrances like these.
Nearby towns we also list for automatic entrance lobbies (straight-line distance): Haddington (10.8 miles), Tranent (17.4 miles), Prestonpans (18.2 miles), Musselburgh (21.1 miles), Mayfield (22.2 miles), Dalkeith (22.7 miles).
What to think about for automatic entrance lobbies in Dunbar
- Measure the depth you can give the lobby before settling on a layout. A lobby that is too shallow lets both sets open together and loses most of its benefit.
- Listed buildings and conservation areas in Dunbar may limit changes to the frontage. An internal lobby behind the existing doors often keeps the street view unchanged, though consent may still be needed.
- Two operators mean two power supplies, or one supply sized for both. Check whether there is a suitable supply at ceiling height, as cable runs across a finished foyer add cost.
- Surgeries and clinics in Dunbar need lobbies wide and deep enough for wheelchairs, mobility scooters and people with walking frames. Avoid interlocks at public entrances unless there is a strong security reason for them.
- Work on a lobby in Dunbar takes longer than a door swap. Ask for the programme in writing, including which entrance stays usable each day and any out-of-hours working.
Automatic entrance lobbies in Dunbar: guide prices
The site survey is free, including the measured drawing and a fixed, itemised written quote. Guide price: typically £14,995 to £34,995 ex VAT.
| Item | Guide price | Notes |
|---|---|---|
| Draught lobby: two sets of automatic sliding doors and glazed screens | £14,995 – £34,995 | doors and screens, installed, ex VAT |
| Lobby with curtain walling or building work | Priced on survey | larger public-sector lobbies have cost £50,000 or more |
| Card or fob reader tied into the door | £795 – £2,495 | per door, ex VAT |
| Battery backup for power-cut operation | £395 – £695 | per door, ex VAT |
Lobby prices cover the doors and glazed screens. Building work, flooring, heating and curtain walling are priced on survey.
Standards and rules in Scotland
Scottish building standards guidance (the non-domestic Technical Handbook) expects an accessible entrance door to give a clear opening of at least 800 mm, says powered doors improve accessibility as long as they add no new hazard, and expects signage, sensors that hold the door open long enough, and guarding against collision or entrapment.
Under the Equality Act 2010, service providers and employers in Scotland must make reasonable adjustments for disabled people, which can include altering a physical feature such as a heavy entrance door. Most building work in Scotland needs a building warrant before it starts, so new entrances are checked with the local authority verifier first.
How it works
- Send photos and the address. A few pictures of the door from both sides, the address in Dunbar and a note of who uses the entrance help us understand the job before anyone visits the site.
- No-cost survey on site. We arrange a survey at a time that suits the building. The engineer records measurements, fixings and power, plus any constraints such as listed status, opening hours or access for deliveries.
- Itemised quote to approve. We price every element of the work on automatic entrance lobbies separately in a written quote that you can check, share and approve. Lead time and payment stages are stated, and nothing is ordered until you accept.
- Fit, test and hand over. On the agreed dates the engineer installs the equipment, commissions the operator and tests each safety function. You get a demonstration, the test record and any conformity paperwork that applies to the work.
If the front of your building in Dunbar is cold and draughty, start with a free survey. Nothing is ordered until you accept the written quote.
Automatic entrance lobbies in Dunbar: questions
Is a revolving door a better option than a lobby in Dunbar?
It can be where space is tight and traffic is steady, because a revolving door seals the entrance at every turn. A revolving door is not accessible on its own, though, so an accessible powered sliding or swing door is needed alongside it. We can price both at survey.
What do you charge for automatic entrance lobbies in Dunbar?
Our guide is £14,995 to £34,995 excluding VAT (per lobby, doors and screens), the same guide prices we use across the UK. The free site survey in Dunbar confirms the price as a fixed, itemised written quote, and the guide price tool gives you a range before anyone visits.
Can you add a lobby to our existing entrance in Dunbar?
Usually, if there is enough depth inside the existing doors or room for a glazed porch outside. We check the space, the floor and the power at the free survey, then quote either an inner set to pair with your current doors or a complete new lobby.
Can the lobby doors in Dunbar be locked at night?
Yes. The outer set is usually locked out of hours, and the inner set can be locked too. Locks and any access control are wired to release on the fire alarm where the fire strategy requires, and the settings are recorded at handover.
Will the building stay secure while the entrance is being changed?
We plan to keep the entrance usable or secure throughout. Where a door has to come out, the work is sequenced so the opening is closed up before the engineer leaves, or a temporary door or hoarding is arranged when a longer gap cannot be avoided. How this is handled for your site in Dunbar is agreed before work starts.
What happens once the installation in Dunbar is finished?
The engineer tests every function, including the safety sensors and the behaviour on power loss, and sets the door up with reference to BS EN 16005. You are shown how to use the controls and which simple checks to make, and you receive the handover documents, including the test record and any conformity paperwork that applies to the work.
Who is responsible for automatic doors on escape routes in Dunbar?
The person responsible for fire safety under the Fire (Scotland) Act 2005 for those premises. Scottish guidance allows automatic doors on escape routes only where they fail safely to outward opening or have a monitored fail-safe system that opens them on power failure, sensor failure and fire alarm.