Covering Hitchin and nearby
Sites across the SG4 and SG5 postcode districts are visited by specialist automatic door engineers working under our management. They travel to Hitchin for automatic entrance lobbies as bookings come in, so dates depend on the diary rather than a fixed local team, and we give you the earliest date we can offer when you book.
Independent businesses in Hitchin often have one entrance and cannot close for long. Work is usually scheduled early, late or on a quiet day, and where a door must be out of use for a period, we plan to keep the entrance usable or secure.
Nearby towns we also list for automatic entrance lobbies (straight-line distance): Letchworth (3.2 miles), Stevenage (4.8 miles), Luton (7.4 miles), Harpenden (9.7 miles), Welwyn Garden City (10.7 miles), Dunstable (11.0 miles).
What to think about for automatic entrance lobbies in Hitchin
- Listed buildings and conservation areas in Hitchin may limit changes to the frontage. An internal lobby behind the existing doors often keeps the street view unchanged, though consent may still be needed.
- High street units in Hitchin often have narrow, shallow shop fronts. An internal lobby may take sales space, so a glazed porch or a sliding outer set with a swing inner set can be a better fit.
- If the lobby is on an escape route, the fire strategy decides what both door sets do on alarm. Sequencing and interlocks must release so nothing stops people leaving.
- Plan for a recessed matting well across the lobby floor. Wet shoes on a hard floor are a slip risk, and loose mats can trip people or upset floor-level sensors.
- Surgeries and clinics in Hitchin need lobbies wide and deep enough for wheelchairs, mobility scooters and people with walking frames. Avoid interlocks at public entrances unless there is a strong security reason for them.
Automatic entrance lobbies in Hitchin: guide prices
The site survey is free, including the measured drawing and a fixed, itemised written quote. Guide price: typically £14,995 to £34,995 ex VAT.
| Item | Guide price | Notes |
|---|---|---|
| Draught lobby: two sets of automatic sliding doors and glazed screens | £14,995 – £34,995 | doors and screens, installed, ex VAT |
| Lobby with curtain walling or building work | Priced on survey | larger public-sector lobbies have cost £50,000 or more |
| Card or fob reader tied into the door | £795 – £2,495 | per door, ex VAT |
| Battery backup for power-cut operation | £395 – £695 | per door, ex VAT |
Lobby prices cover the doors and glazed screens. Building work, flooring, heating and curtain walling are priced on survey.
Standards and rules in England
In Great Britain a new or converted powered door must meet the Supply of Machinery (Safety) Regulations 2008 before it is first used, and can carry the UKCA or the CE marking. Workplace law (the Workplace (Health, Safety and Welfare) Regulations 1992) expects powered doors to have suitable and effective features to stop them trapping anyone and, where needed for safety, to open by hand unless they open automatically if the power fails. Doors at work must also be kept in efficient working order under a suitable system of maintenance.
Under the Equality Act 2010, service providers and employers must make reasonable adjustments for disabled people, which can include altering a physical feature such as a heavy entrance door. New entrances and some alterations count as building work, so check with building control before the work is ordered.
How it works
- Tell us about the entrance. Send the address, a few photos and a rough size of the opening, and say how the door is used. That is enough for us to suggest options for automatic entrance lobbies and book a survey in Hitchin.
- Free site survey. A specialist engineer working under our management measures the opening, checks the frame, floor, head height and power, and talks through how people use the entrance. There is no charge and no obligation.
- Fixed written quote. You receive a fixed, itemised written quote with the specification, lead time, payment stages and warranty terms. The price does not change unless the scope does, and any change is agreed in writing first.
- Installation and handover. The door is fitted on the agreed dates, then set up, tested and documented with reference to BS EN 16005. You are shown the controls and the simple checks to make, and receive the handover paperwork.
If the front of your building in Hitchin is cold and draughty, start with a free survey. Nothing is ordered until you accept the written quote.
Automatic entrance lobbies in Hitchin: questions
Is a revolving door a better option than a lobby in Hitchin?
It can be where space is tight and traffic is steady, because a revolving door seals the entrance at every turn. A revolving door is not accessible on its own, though, so an accessible powered sliding or swing door is needed alongside it. We can price both at survey.
What do you charge for automatic entrance lobbies in Hitchin?
Our guide is £14,995 to £34,995 excluding VAT (per lobby, doors and screens), the same guide prices we use across the UK. The free site survey in Hitchin confirms the price as a fixed, itemised written quote, and the guide price tool gives you a range before anyone visits.
Do you design lobbies for new buildings in Hitchin?
Yes. We can work from the architect's drawings, suggest door types and depth, and quote the doors, screens and controls as one package for the main contractor or the client. Designing the lobby in at the start is usually simpler and cheaper than adding it later.
Can you look after the lobby doors in Hitchin after installation?
We can arrange planned servicing for both door sets, checking sequencing, safety sensors and alarm releases at each visit and leaving a written record. Servicing is charged per visit, and the price is confirmed in writing before an engineer comes out.
What does the free site survey in Hitchin involve?
An engineer working under our management visits the building, measures the opening, checks the frame, floor, head height and power supply, and looks at how people use the entrance. The survey is free and carries no obligation. Afterwards you receive a fixed, itemised written quote for automatic entrance lobbies, with drawings where the door type needs them.
Will the building stay secure while the entrance is being changed?
We plan to keep the entrance usable or secure throughout. Where a door has to come out, the work is sequenced so the opening is closed up before the engineer leaves, or a temporary door or hoarding is arranged when a longer gap cannot be avoided. How this is handled for your site in Hitchin is agreed before work starts.
Do businesses in Hitchin have to fit automatic doors?
No law says every building must have automatic doors. Under the Equality Act 2010, service providers and employers must make reasonable adjustments for disabled people, and building regulations guidance in England calls for a powered door where an entrance door would otherwise be too heavy to open. An automatic door is often the simplest way to meet both.