Access control for automatic doors · Somerset

Access control for automatic doors in Taunton

Offices and clinics in Taunton often want the main door open to the public by day and card-only at night. A schedule linked to the door operator does that automatically, with an electric lock for out-of-hours security.

Town
Taunton
Area
Somerset
Postcodes
TA1, TA2
Guide price
From £795 ex VAT
  • Free site survey for new doors
  • Fixed, itemised written quote
  • Set up with reference to BS EN 16005
  • England, Wales, Scotland and NI
  • Guide prices published

Covering Taunton and nearby

Addresses anywhere in the TA1 and TA2 postcode districts can book access control for automatic doors through us. The engineer who attends works under our management and travels to the site. There is no branch in Taunton, so the price, the booking and the paperwork all come from one place.

Housing providers and managing agents in Taunton look after communal entrance doors that are used day and night. Reliable closing, good security and a written service record are usually the priorities, along with door entry or fob systems tied into the operator.

Nearby towns we also list for access control for automatic doors (straight-line distance): Bridgwater (8.9 miles), Burnham-on-Sea (16.1 miles), Tiverton (18.6 miles), Yeovil (21.1 miles), Weston-super-Mare (23.5 miles), Exeter (27.3 miles).

What to think about for access control for automatic doors in Taunton

  • Decide how the door should behave at each time of day before the survey. Opening hours, cleaning shifts, deliveries and weekend events all affect the schedule the door will follow.
  • Older automatic doors in Taunton may not have inputs for access control. The survey checks this, and an older operator may need upgrading or replacing before readers can be linked.
  • Doors on escape routes need locks that release on alarm and on power loss. Check the fire strategy, or ask your fire risk assessor, before choosing a lock.
  • Cable routes matter. Running cables between a reader, a controller and the operator through finished walls and ceilings can be a large share of the cost.
  • Offices on business parks in Taunton often share entrances between tenants. Agree whose system controls the door, who pays for it and who can add or remove cards.

Access control for automatic doors in Taunton: guide prices

The site survey is free, including the measured drawing and a fixed, itemised written quote. Guide price: from £795 ex VAT.

ItemGuide priceNotes
Card or fob reader tied into the door£795 – £2,495per door, ex VAT
Intercom or door entry tie-infrom £495priced on survey, ex VAT
Timed locking and night mode set-upincluded with the aboveprogrammed at commissioning
Electric lock added to an automatic dooron surveydepends on the door and the lock type

Standards and rules in England

Under the Equality Act 2010, service providers and employers must make reasonable adjustments for disabled people, which can include altering a physical feature such as a heavy entrance door. Fitting an automatic door helps, but does not on its own guarantee those duties are met.

Building regulations guidance in England (Approved Document M, Volume 2) says a powered opening system should be used where a self-closing entrance door would need more than 30 N at the leading edge to open, or more than 22.5 N between 30° and 60°, and expects external doors used by the public in new buildings to give at least 1000 mm of effective clear width.

How it works

  1. Send photos and the address. A few pictures of the door from both sides, the address in Taunton and a note of who uses the entrance help us understand the job before anyone visits the site.
  2. No-cost survey on site. We arrange a survey at a time that suits the building. The engineer records measurements, fixings and power, plus any constraints such as listed status, opening hours or access for deliveries.
  3. Itemised quote to approve. We price every element of the work on access control for automatic doors separately in a written quote that you can check, share and approve. Lead time and payment stages are stated, and nothing is ordered until you accept.
  4. Fit, test and hand over. On the agreed dates the engineer installs the equipment, commissions the operator and tests each safety function. You get a demonstration, the test record and any conformity paperwork that applies to the work.

Book a free survey of your entrance in Taunton, and we will check the operator, the lock and your existing system before quoting.

Access control for automatic doors in Taunton: questions

Can our door in Taunton run on a schedule?

Yes. The door can open freely during opening hours and switch to card or code entry with the lock engaged at night, at weekends and on holiday dates. Staff can override the schedule with a key switch if they need to.

How are prices worked out for access control for automatic doors in Taunton?

Our guide starts from £795 excluding VAT (per door), the same guide price we use across the UK. The free site survey in Taunton confirms the price as a fixed, itemised written quote, and the guide price tool gives you a range before anyone visits.

Can you add access control to our automatic door in Taunton?

In most cases, yes. We check the operator's inputs, the lock options and the cable route at a free survey, then quote a fixed price. We can connect to your existing system or supply a standalone reader or keypad for the door.

Can you fit fob entry to a residential block in Taunton?

Yes. We can fit fob readers and video entry to an automatic communal door, set up so residents use fobs and visitors call the flat. Fire alarm and power-loss behaviour are agreed with the managing agent or housing provider before we commission the door.

Will the building stay secure while the entrance is being changed?

We plan to keep the entrance usable or secure throughout. Where a door has to come out, the work is sequenced so the opening is closed up before the engineer leaves, or a temporary door or hoarding is arranged when a longer gap cannot be avoided. How this is handled for your site in Taunton is agreed before work starts.

Is there a warranty on access control for automatic doors?

Yes. The warranty terms for the equipment and the installation are set out in your written quote, so you can see exactly what is covered before you accept. Keeping the door serviced at the recommended intervals helps keep it in good order, and the quote explains any conditions that apply to the warranty.

Which building regulations apply to a new automatic entrance in Taunton?

In England the guidance is Approved Document M (Volume 2) for access, Approved Document B for fire safety and escape routes, and Approved Document K for glazing and powered doors. A new entrance can count as building work, so building control should be involved before it is ordered.

Next step

Access control for automatic doors in Taunton

Send the address, a photo if you have one and what the door needs to do. New installations get a free site survey and a fixed written quote; repairs and servicing are priced in writing before we attend.