Coverage across Orkney, Shetland and the Western Isles
Not every part of Orkney, Shetland and the Western Isles is easy to reach, and some sites need planning around access, parking or opening hours. We take that into account when arranging access control for automatic doors, and the engineer, working under our management, arrives with what the job is likely to need. The towns below, 4 in all, each have their own page, but any address in the area can be covered.
Towns listed in Orkney, Shetland and the Western Isles: Stornoway, Kirkwall, Lerwick, Stromness.
What to think about for access control for automatic doors in Orkney, Shetland and the Western Isles
- Glass entrances may not have an obvious place for a reader. A post-mounted reader, or one fitted to a side screen, can avoid drilling into the door frame.
- If you already have an access control system, find out who installed and maintains it. Linking an automatic door is simpler when your security installer is part of the plan.
- Offices on business parks in Orkney, Shetland and the Western Isles often share entrances between tenants. Agree whose system controls the door, who pays for it and who can add or remove cards.
- Residential blocks in Orkney, Shetland and the Western Isles usually have a managing agent or housing provider who sets the rules for fobs, visitors and fire alarm behaviour. Involve them early.
- Healthcare sites in Orkney, Shetland and the Western Isles often control access to wards and staff areas. Think about how visitors, porters and emergency teams will get through at every hour.
Access control for automatic doors in Orkney, Shetland and the Western Isles: guide prices
The site survey is free, including the measured drawing and a fixed, itemised written quote. For island addresses the survey is still free; travel and accommodation for the installation itself are shown as a separate line in the quote. Guide price: from £795 ex VAT.
| Item | Guide price | Notes |
|---|---|---|
| Card or fob reader tied into the door | £795 – £2,495 | per door, ex VAT |
| Intercom or door entry tie-in | from £495 | priced on survey, ex VAT |
| Timed locking and night mode set-up | included with the above | programmed at commissioning |
| Electric lock added to an automatic door | on survey | depends on the door and the lock type |
Standards and rules in Scotland
Under the Equality Act 2010, service providers and employers in Scotland must make reasonable adjustments for disabled people, which can include altering a physical feature such as a heavy entrance door. Fitting an automatic door helps, but does not on its own guarantee those duties are met.
Scottish building standards guidance (the non-domestic Technical Handbook) expects an accessible entrance door to give a clear opening of at least 800 mm, says powered doors improve accessibility as long as they add no new hazard, and expects signage, sensors that hold the door open long enough, and guarding against collision or entrapment.
Whoever motorises a manual door, or builds an automatic door from separate parts, may take on the manufacturer’s legal duties for the finished door: a risk assessment, a technical file kept available for the authorities, a Declaration of Conformity, the conformity marking and instructions. You receive the Declaration of Conformity and the instructions at handover. In Great Britain a new or converted powered door must meet the Supply of Machinery (Safety) Regulations 2008 before it is first used, and can carry the UKCA or the CE marking.
How it works
- Describe what you need. Whether the job is access control for automatic doors for a busy entrance or for a single internal door, a brief description and some photos let us understand it and plan a survey visit in Orkney, Shetland and the Western Isles.
- Free visit to the site. An engineer working under our management assesses the opening, the existing door and frame, the floor and the electrical supply, and notes any access, consent or timing issues to plan around.
- Your fixed quotation. The quote is fixed for the work it describes and lists each item, including any removal, making good and electrical work. It also states the lead time, the payment stages and the warranty terms.
- Fitting and sign-off. Work goes ahead on dates agreed with you. Once fitted, the door is adjusted and its safety functions are tested and recorded with reference to BS EN 16005, and you are shown how to use it.
Send us details of your current access control and the door in Orkney, Shetland and the Western Isles, and we will plan how to link the two.
Access control for automatic doors in Orkney, Shetland and the Western Isles: questions
Can you add access control to our automatic door in Orkney, Shetland and the Western Isles?
In most cases, yes. We check the operator's inputs, the lock options and the cable route at a free survey, then quote a fixed price. We can connect to your existing system or supply a standalone reader or keypad for the door.
Can you give me a price for access control for automatic doors in Orkney, Shetland and the Western Isles?
Our guide starts from £795 excluding VAT (per door), the same guide price we use across the UK. The free site survey in Orkney, Shetland and the Western Isles confirms the price as a fixed, itemised written quote, and the guide price tool gives you a range before anyone visits.
Do you work with our security installer in Orkney, Shetland and the Western Isles?
Yes. Where a security installer already looks after your access control, we usually handle the door, the lock and the link to the operator, and they handle the reader, controller and permissions. The quote sets out who does what so nothing falls between the two.
Will our door in Orkney, Shetland and the Western Isles still release when the fire alarm sounds?
On an escape route, yes. Locks are wired to release on the fire alarm signal and, where the fire strategy requires it, the door opens and holds open. We test this with your fire alarm contractor at handover and record the result.
What happens to the old door when a new one is fitted in Orkney, Shetland and the Western Isles?
If the work replaces an existing door, frame or operator, removal and disposal are listed in the quote. The old door comes out only when the new one is ready to go in, so the opening is not left empty for longer than necessary. Making good to the surrounding wall, floor or ceiling is included where the quote says so.
What happens once the installation in Orkney, Shetland and the Western Isles is finished?
The engineer tests every function, including the safety sensors and the behaviour on power loss, and sets the door up with reference to BS EN 16005. You are shown how to use the controls and which simple checks to make, and you receive the handover documents, including the test record and any conformity paperwork that applies to the work.
Who is responsible for automatic doors on escape routes in Orkney, Shetland and the Western Isles?
The person responsible for fire safety under the Fire (Scotland) Act 2005 for those premises. Scottish guidance allows automatic doors on escape routes only where they fail safely to outward opening or have a monitored fail-safe system that opens them on power failure, sensor failure and fire alarm.