Coverage across Norfolk
Our coverage of Norfolk is not tied to a depot or a showroom. Engineers who carry out access control for automatic doors for us travel to each site, so a farm shop down a country lane goes through the same process as a city-centre office. Every job is priced in writing before work starts, and the town list below currently numbers 7.
Towns listed in Norfolk: Norwich, Great Yarmouth, King's Lynn, Thetford, Dereham, Gorleston-on-Sea, Wymondham.
What to think about for access control for automatic doors in Norfolk
- Older automatic doors in Norfolk may not have inputs for access control. The survey checks this, and an older operator may need upgrading or replacing before readers can be linked.
- Offices on business parks in Norfolk often share entrances between tenants. Agree whose system controls the door, who pays for it and who can add or remove cards.
- Residential blocks in Norfolk usually have a managing agent or housing provider who sets the rules for fobs, visitors and fire alarm behaviour. Involve them early.
- Doors on escape routes need locks that release on alarm and on power loss. Check the fire strategy, or ask your fire risk assessor, before choosing a lock.
- Healthcare sites in Norfolk often control access to wards and staff areas. Think about how visitors, porters and emergency teams will get through at every hour.
Access control for automatic doors in Norfolk: guide prices
The site survey is free, including the measured drawing and a fixed, itemised written quote. Guide price: from £795 ex VAT.
| Item | Guide price | Notes |
|---|---|---|
| Card or fob reader tied into the door | £795 – £2,495 | per door, ex VAT |
| Intercom or door entry tie-in | from £495 | priced on survey, ex VAT |
| Timed locking and night mode set-up | included with the above | programmed at commissioning |
| Electric lock added to an automatic door | on survey | depends on the door and the lock type |
Standards and rules in England
Under the Equality Act 2010, service providers and employers must make reasonable adjustments for disabled people, which can include altering a physical feature such as a heavy entrance door. Fitting an automatic door helps, but does not on its own guarantee those duties are met.
Building regulations guidance in England (Approved Document M, Volume 2) says a powered opening system should be used where a self-closing entrance door would need more than 30 N at the leading edge to open, or more than 22.5 N between 30° and 60°, and expects external doors used by the public in new buildings to give at least 1000 mm of effective clear width.
Whoever motorises a manual door, or builds an automatic door from separate parts, may take on the manufacturer’s legal duties for the finished door: a risk assessment, a technical file kept available for the authorities, a Declaration of Conformity, the conformity marking and instructions. You receive the Declaration of Conformity and the instructions at handover. In Great Britain a new or converted powered door must meet the Supply of Machinery (Safety) Regulations 2008 before it is first used, and can carry the UKCA or the CE marking.
How it works
- Describe what you need. Whether the job is access control for automatic doors for a busy entrance or for a single internal door, a brief description and some photos let us understand it and plan a survey visit in Norfolk.
- Free visit to the site. An engineer working under our management assesses the opening, the existing door and frame, the floor and the electrical supply, and notes any access, consent or timing issues to plan around.
- Your fixed quotation. The quote is fixed for the work it describes and lists each item, including any removal, making good and electrical work. It also states the lead time, the payment stages and the warranty terms.
- Fitting and sign-off. Work goes ahead on dates agreed with you. Once fitted, the door is adjusted and its safety functions are tested and recorded with reference to BS EN 16005, and you are shown how to use it.
Book a free survey of your entrance in Norfolk, and we will check the operator, the lock and your existing system before quoting.
Access control for automatic doors in Norfolk: questions
Can you add access control to our automatic door in Norfolk?
In most cases, yes. We check the operator's inputs, the lock options and the cable route at a free survey, then quote a fixed price. We can connect to your existing system or supply a standalone reader or keypad for the door.
What is the guide price for access control for automatic doors in Norfolk?
Our guide starts from £795 excluding VAT (per door), the same guide price we use across the UK. The free site survey in Norfolk confirms the price as a fixed, itemised written quote, and the guide price tool gives you a range before anyone visits.
Can you fit fob entry to a residential block in Norfolk?
Yes. We can fit fob readers and video entry to an automatic communal door, set up so residents use fobs and visitors call the flat. Fire alarm and power-loss behaviour are agreed with the managing agent or housing provider before we commission the door.
Can you service the door and access control in Norfolk together?
We can service the door and test the link to the access control on each visit, leaving a written record. Visits are chargeable and priced in writing before anyone attends. If your security installer looks after the system, we can coordinate visits with them.
What happens to the old door when a new one is fitted in Norfolk?
If the work replaces an existing door, frame or operator, removal and disposal are listed in the quote. The old door comes out only when the new one is ready to go in, so the opening is not left empty for longer than necessary. Making good to the surrounding wall, floor or ceiling is included where the quote says so.
Can installation in Norfolk happen outside opening hours?
Yes. Many shops, surgeries and offices prefer work early in the morning, in the evening or at weekends, when the entrance is quietest. Tell us your constraints when you enquire and they are built into the plan. Any extra cost for out-of-hours work is shown in the written quote rather than added afterwards.
Which building regulations apply to a new automatic entrance in Norfolk?
In England the guidance is Approved Document M (Volume 2) for access, Approved Document B for fire safety and escape routes, and Approved Document K for glazing and powered doors. A new entrance can count as building work, so building control should be involved before it is ordered.