UK-wide · Free site survey and fixed written quote for new doors · Repair and service visits priced before we attend

Call 0800 088 6248

Automatic Door Installers

Access control for automatic doors · Kent

Access control for automatic doors in Canterbury

Offices and clinics in Canterbury often want the main door open to the public by day and card-only at night. A schedule linked to the door operator does that automatically, with an electric lock for out-of-hours security.

Town
Canterbury
Area
Kent
Postcodes
CT1, CT2
Guide price
From £795 ex VAT
  • Free site survey for new doors
  • Fixed, itemised written quote
  • Set up with reference to BS EN 16005
  • England, Wales, Scotland and NI
  • Guide prices published

Covering Canterbury and nearby

For access control for automatic doors, coverage around Canterbury is set by postcode and includes the CT1 and CT2 postcode districts, as well as nearby addresses in Kent. Specialist engineers working under our management attend each site, and the price is agreed in writing beforehand.

Housing providers and managing agents in Canterbury look after communal entrance doors that are used day and night. Reliable closing, good security and a written service record are usually the priorities, along with door entry or fob systems tied into the operator.

Nearby towns we also list for access control for automatic doors (straight-line distance): Whitstable (6.1 miles), Herne Bay (6.8 miles), Faversham (8.6 miles), Ashford (12.8 miles), Folkestone (14.2 miles), Deal (14.5 miles).

What to think about for access control for automatic doors in Canterbury

  • Doors on escape routes need locks that release on alarm and on power loss. Check the fire strategy, or ask your fire risk assessor, before choosing a lock.
  • Decide how the door should behave at each time of day before the survey. Opening hours, cleaning shifts, deliveries and weekend events all affect the schedule the door will follow.
  • Older automatic doors in Canterbury may not have inputs for access control. The survey checks this, and an older operator may need upgrading or replacing before readers can be linked.
  • Offices on business parks in Canterbury often share entrances between tenants. Agree whose system controls the door, who pays for it and who can add or remove cards.
  • A video entry system needs a network or cable link between the door and wherever visitors are answered. Check the route before the survey, especially across car parks or between buildings.

Access control for automatic doors in Canterbury: guide prices

The site survey is free, including the measured drawing and a fixed, itemised written quote. Guide price: from £795 ex VAT.

ItemGuide priceNotes
Card or fob reader tied into the door£795 – £2,495per door, ex VAT
Intercom or door entry tie-infrom £495priced on survey, ex VAT
Timed locking and night mode set-upincluded with the aboveprogrammed at commissioning
Electric lock added to an automatic dooron surveydepends on the door and the lock type

Standards and rules in England

Under the Equality Act 2010, service providers and employers must make reasonable adjustments for disabled people, which can include altering a physical feature such as a heavy entrance door. Fitting an automatic door helps, but does not on its own guarantee those duties are met.

Whoever motorises a manual door, or builds an automatic door from separate parts, may take on the manufacturer’s legal duties for the finished door: a risk assessment, a technical file kept available for the authorities, a Declaration of Conformity, the conformity marking and instructions. You receive the Declaration of Conformity and the instructions at handover. In Great Britain a new or converted powered door must meet the Supply of Machinery (Safety) Regulations 2008 before it is first used, and can carry the UKCA or the CE marking.

How it works

  1. Start with a short enquiry. Use the form, phone or email. Tell us whether the work is a new door, an upgrade or an opener for a home, and we arrange the next step for your site in Canterbury.
  2. Measured survey. The free survey confirms what will fit and what the entrance needs: opening width, door type, activation, safety sensors and behaviour on power loss or fire alarm, matched to how the building is used.
  3. Written price, no surprises. A fixed, itemised quote sets out the specification, the work involved, the expected lead time and the warranty terms. You can ask questions or change the specification before accepting it.
  4. Installed and commissioned. The door is installed with as little disruption as possible, then set up and tested for its hazard zones. Before leaving, the engineer explains the controls and hands over the documents for your records.

From a single keypad to readers on every entrance, get a written quote for access control in Canterbury, starting with a free survey.

Access control for automatic doors in Canterbury: questions

Can our door in Canterbury run on a schedule?

Yes. The door can open freely during opening hours and switch to card or code entry with the lock engaged at night, at weekends and on holiday dates. Staff can override the schedule with a key switch if they need to.

What price range should I expect for access control for automatic doors in Canterbury?

Our guide starts from £795 excluding VAT (per door), the same guide price we use across the UK. The free site survey in Canterbury confirms the price as a fixed, itemised written quote, and the guide price tool gives you a range before anyone visits.

Our automatic door in Canterbury is quite old. Can access control still be added?

Sometimes. Older operators may not have suitable inputs, or may not support an electric lock. The survey checks this, and if the operator needs upgrading first, the quote shows the cost of both, so you can decide. An older door may also benefit from a safety inspection at the same time.

Can you add access control to our automatic door in Canterbury?

In most cases, yes. We check the operator's inputs, the lock options and the cable route at a free survey, then quote a fixed price. We can connect to your existing system or supply a standalone reader or keypad for the door.

How much disruption should we expect while the work is done in Canterbury?

Most installations take one visit or a short series of visits, with dust and noise kept to the area around the door. The engineer screens off the work area, keeps a route in or out where possible and clears up before leaving. Larger entrances, lobbies or structural changes take longer, and the quote explains how that work is phased.

What happens once the installation in Canterbury is finished?

The engineer tests every function, including the safety sensors and the behaviour on power loss, and sets the door up with reference to BS EN 16005. You are shown how to use the controls and which simple checks to make, and you receive the handover documents, including the test record and any conformity paperwork that applies to the work.

Who is responsible for automatic doors on escape routes in Canterbury?

Under the Regulatory Reform (Fire Safety) Order 2005 the responsible person for the premises must make sure escape routes work and fire safety equipment is maintained. Automatic doors on an escape route need fail-safe opening or break-out, set by the fire strategy.

Next step

Access control for automatic doors in Canterbury

Send the address, a photo if you have one and what the door needs to do. New installations get a free site survey and a fixed written quote; repairs and servicing are priced in writing before we attend.