Covering Braintree and nearby
We do not keep premises in Braintree. Instead, enquiries about access control for automatic doors come to us, we agree the price in writing, and a specialist engineer working under our management travels to the address in the CM7 and CM77 postcode districts on a date that suits the site.
Weather matters for entrances that face open car parks, which is common on retail and business parks around Braintree and elsewhere in Essex. Exposed doors can be pushed by wind and let heat escape, so draught lobbies, good seals and correctly set sensors are worth considering.
Nearby towns we also list for access control for automatic doors (straight-line distance): Witham (6.6 miles), Chelmsford (10.5 miles), Maldon (11.4 miles), Sudbury (13.4 miles), Haverhill (14.9 miles), Colchester (15.0 miles).
What to think about for access control for automatic doors in Braintree
- A video entry system needs a network or cable link between the door and wherever visitors are answered. Check the route before the survey, especially across car parks or between buildings.
- Older automatic doors in Braintree may not have inputs for access control. The survey checks this, and an older operator may need upgrading or replacing before readers can be linked.
- Cable routes matter. Running cables between a reader, a controller and the operator through finished walls and ceilings can be a large share of the cost.
- Decide how the door should behave at each time of day before the survey. Opening hours, cleaning shifts, deliveries and weekend events all affect the schedule the door will follow.
- Doors on escape routes need locks that release on alarm and on power loss. Check the fire strategy, or ask your fire risk assessor, before choosing a lock.
Access control for automatic doors in Braintree: guide prices
The site survey is free, including the measured drawing and a fixed, itemised written quote. Guide price: from £795 ex VAT.
| Item | Guide price | Notes |
|---|---|---|
| Card or fob reader tied into the door | £795 – £2,495 | per door, ex VAT |
| Intercom or door entry tie-in | from £495 | priced on survey, ex VAT |
| Timed locking and night mode set-up | included with the above | programmed at commissioning |
| Electric lock added to an automatic door | on survey | depends on the door and the lock type |
Standards and rules in England
Building regulations guidance in England (Approved Document M, Volume 2) says a powered opening system should be used where a self-closing entrance door would need more than 30 N at the leading edge to open, or more than 22.5 N between 30° and 60°, and expects external doors used by the public in new buildings to give at least 1000 mm of effective clear width.
Whoever motorises a manual door, or builds an automatic door from separate parts, may take on the manufacturer’s legal duties for the finished door: a risk assessment, a technical file kept available for the authorities, a Declaration of Conformity, the conformity marking and instructions. You receive the Declaration of Conformity and the instructions at handover. In Great Britain a new or converted powered door must meet the Supply of Machinery (Safety) Regulations 2008 before it is first used, and can carry the UKCA or the CE marking.
How it works
- Send photos and the address. A few pictures of the door from both sides, the address in Braintree and a note of who uses the entrance help us understand the job before anyone visits the site.
- No-cost survey on site. We arrange a survey at a time that suits the building. The engineer records measurements, fixings and power, plus any constraints such as listed status, opening hours or access for deliveries.
- Itemised quote to approve. We price every element of the work on access control for automatic doors separately in a written quote that you can check, share and approve. Lead time and payment stages are stated, and nothing is ordered until you accept.
- Fit, test and hand over. On the agreed dates the engineer installs the equipment, commissions the operator and tests each safety function. You get a demonstration, the test record and any conformity paperwork that applies to the work.
From a single keypad to readers on every entrance, get a written quote for access control in Braintree, starting with a free survey.
Access control for automatic doors in Braintree: questions
How long does installation take at our building in Braintree?
Lead time is typically 2 to 4 weeks from order. Most single doors are wired and commissioned in a day, though longer cable runs or several doors take more time. We agree working hours with you so the entrance stays usable.
How are prices worked out for access control for automatic doors in Braintree?
Our guide starts from £795 excluding VAT (per door), the same guide price we use across the UK. The free site survey in Braintree confirms the price as a fixed, itemised written quote, and the guide price tool gives you a range before anyone visits.
Can you fit fob entry to a residential block in Braintree?
Yes. We can fit fob readers and video entry to an automatic communal door, set up so residents use fobs and visitors call the flat. Fire alarm and power-loss behaviour are agreed with the managing agent or housing provider before we commission the door.
Do you work with our security installer in Braintree?
Yes. Where a security installer already looks after your access control, we usually handle the door, the lock and the link to the operator, and they handle the reader, controller and permissions. The quote sets out who does what so nothing falls between the two.
What happens once the installation in Braintree is finished?
The engineer tests every function, including the safety sensors and the behaviour on power loss, and sets the door up with reference to BS EN 16005. You are shown how to use the controls and which simple checks to make, and you receive the handover documents, including the test record and any conformity paperwork that applies to the work.
Do you service doors in Braintree after installing them?
Yes. We recommend a trained engineer checks the safety functions at least once a year, with service intervals set by the manufacturer's instructions and how heavily the door is used; busy doors are often serviced more often. Servicing can follow on from the installation, with the price agreed in writing and a record left after every visit.
Who is responsible for automatic doors on escape routes in Braintree?
Under the Regulatory Reform (Fire Safety) Order 2005 the responsible person for the premises must make sure escape routes work and fire safety equipment is maintained. Automatic doors on an escape route need fail-safe opening or break-out, set by the fire strategy.