Covering Falmouth and nearby
If your building is in Falmouth, or anywhere in the TR11 postcode district, we can arrange access control for automatic doors. Visits are booked with you in advance, timed around opening hours where that matters, and carried out by engineers who work under our management.
Care homes in and around Falmouth often need automatic doors on corridors and day rooms as well as at the main entrance. Gentle operation, hold-open devices linked to the fire alarm and controlled exits help residents move about safely.
Nearby towns we also list for access control for automatic doors (straight-line distance): Truro (7.7 miles), Redruth (8.7 miles), Camborne (10.8 miles), Newquay (18.0 miles), St Austell (18.5 miles), Penzance (20.8 miles).
What to think about for access control for automatic doors in Falmouth
- Schools in Falmouth often want a remote release at the office and a schedule for drop-off and pick-up times. Agree how the door behaves in a lockdown with your safeguarding lead.
- A video entry system needs a network or cable link between the door and wherever visitors are answered. Check the route before the survey, especially across car parks or between buildings.
- If you already have an access control system, find out who installed and maintains it. Linking an automatic door is simpler when your security installer is part of the plan.
- Older automatic doors in Falmouth may not have inputs for access control. The survey checks this, and an older operator may need upgrading or replacing before readers can be linked.
- Decide how the door should behave at each time of day before the survey. Opening hours, cleaning shifts, deliveries and weekend events all affect the schedule the door will follow.
Access control for automatic doors in Falmouth: guide prices
The site survey is free, including the measured drawing and a fixed, itemised written quote. Guide price: from £795 ex VAT.
| Item | Guide price | Notes |
|---|---|---|
| Card or fob reader tied into the door | £795 – £2,495 | per door, ex VAT |
| Intercom or door entry tie-in | from £495 | priced on survey, ex VAT |
| Timed locking and night mode set-up | included with the above | programmed at commissioning |
| Electric lock added to an automatic door | on survey | depends on the door and the lock type |
Standards and rules in England
Building regulations guidance in England (Approved Document M, Volume 2) says a powered opening system should be used where a self-closing entrance door would need more than 30 N at the leading edge to open, or more than 22.5 N between 30° and 60°, and expects external doors used by the public in new buildings to give at least 1000 mm of effective clear width.
Whoever motorises a manual door, or builds an automatic door from separate parts, may take on the manufacturer’s legal duties for the finished door: a risk assessment, a technical file kept available for the authorities, a Declaration of Conformity, the conformity marking and instructions. You receive the Declaration of Conformity and the instructions at handover. In Great Britain a new or converted powered door must meet the Supply of Machinery (Safety) Regulations 2008 before it is first used, and can carry the UKCA or the CE marking.
How it works
- Describe what you need. Whether the job is access control for automatic doors for a busy entrance or for a single internal door, a brief description and some photos let us understand it and plan a survey visit in Falmouth.
- Free visit to the site. An engineer working under our management assesses the opening, the existing door and frame, the floor and the electrical supply, and notes any access, consent or timing issues to plan around.
- Your fixed quotation. The quote is fixed for the work it describes and lists each item, including any removal, making good and electrical work. It also states the lead time, the payment stages and the warranty terms.
- Fitting and sign-off. Work goes ahead on dates agreed with you. Once fitted, the door is adjusted and its safety functions are tested and recorded with reference to BS EN 16005, and you are shown how to use it.
Ask for a fixed price on access control for an automatic door in Falmouth. The quote covers the reader, lock, wiring, testing and handover records.
Access control for automatic doors in Falmouth: questions
Can you fit fob entry to a residential block in Falmouth?
Yes. We can fit fob readers and video entry to an automatic communal door, set up so residents use fobs and visitors call the flat. Fire alarm and power-loss behaviour are agreed with the managing agent or housing provider before we commission the door.
What do you charge for access control for automatic doors in Falmouth?
Our guide starts from £795 excluding VAT (per door), the same guide price we use across the UK. The free site survey in Falmouth confirms the price as a fixed, itemised written quote, and the guide price tool gives you a range before anyone visits.
Will our door in Falmouth still release when the fire alarm sounds?
On an escape route, yes. Locks are wired to release on the fire alarm signal and, where the fire strategy requires it, the door opens and holds open. We test this with your fire alarm contractor at handover and record the result.
Our automatic door in Falmouth is quite old. Can access control still be added?
Sometimes. Older operators may not have suitable inputs, or may not support an electric lock. The survey checks this, and if the operator needs upgrading first, the quote shows the cost of both, so you can decide. An older door may also benefit from a safety inspection at the same time.
What power supply is needed for access control for automatic doors in Falmouth?
Most powered doors need a fused spur close to the operator, and some activation and access control devices also need a low-voltage link. The survey checks what is already there. If a new supply is required, the quote says whether we arrange it or your own electrician does, so nothing is left unclear on the day.
What happens to the old door when a new one is fitted in Falmouth?
If the work replaces an existing door, frame or operator, removal and disposal are listed in the quote. The old door comes out only when the new one is ready to go in, so the opening is not left empty for longer than necessary. Making good to the surrounding wall, floor or ceiling is included where the quote says so.
Which building regulations apply to a new automatic entrance in Falmouth?
In England the guidance is Approved Document M (Volume 2) for access, Approved Document B for fire safety and escape routes, and Approved Document K for glazing and powered doors. A new entrance can count as building work, so building control should be involved before it is ordered.