UK-wide · Free site survey and fixed written quote for new doors · Repair and service visits priced before we attend

Call 0800 088 6248

Automatic Door Installers

Access control for automatic doors · Buckinghamshire

Access control for automatic doors in Gerrards Cross

Communal entrances to residential blocks in Gerrards Cross often combine fob entry for residents with video entry for visitors. An automatic door on that entrance makes life easier for disabled residents and anyone carrying shopping or steering a pushchair.

Town
Gerrards Cross
Area
Buckinghamshire
Postcodes
SL9
Guide price
From £795 ex VAT
  • Free site survey for new doors
  • Fixed, itemised written quote
  • Set up with reference to BS EN 16005
  • England, Wales, Scotland and NI
  • Guide prices published

Covering Gerrards Cross and nearby

Coverage for access control for automatic doors runs across the SL9 postcode district and out into the surrounding parts of Buckinghamshire. Wherever the building is, the arrangements stay the same: one contracting party, a written price before work, and a specialist engineer working under our management on site.

Doors at quieter sites in Gerrards Cross and elsewhere in Buckinghamshire can go many years between checks. A safety inspection looks at how the sensors, closing behaviour and emergency functions are working, and gives you a written record to keep on file.

Nearby towns we also list for access control for automatic doors (straight-line distance): Chalfont St Peter (1.6 miles), Uxbridge (4.1 miles), Rickmansworth (5.0 miles), Slough (5.6 miles), Ruislip (5.7 miles), Amersham (6.2 miles).

What to think about for access control for automatic doors in Gerrards Cross

  • Residential blocks in Gerrards Cross usually have a managing agent or housing provider who sets the rules for fobs, visitors and fire alarm behaviour. Involve them early.
  • A video entry system needs a network or cable link between the door and wherever visitors are answered. Check the route before the survey, especially across car parks or between buildings.
  • If you already have an access control system, find out who installed and maintains it. Linking an automatic door is simpler when your security installer is part of the plan.
  • Doors on escape routes need locks that release on alarm and on power loss. Check the fire strategy, or ask your fire risk assessor, before choosing a lock.
  • Decide how the door should behave at each time of day before the survey. Opening hours, cleaning shifts, deliveries and weekend events all affect the schedule the door will follow.

Access control for automatic doors in Gerrards Cross: guide prices

The site survey is free, including the measured drawing and a fixed, itemised written quote. Guide price: from £795 ex VAT.

ItemGuide priceNotes
Card or fob reader tied into the door£795 – £2,495per door, ex VAT
Intercom or door entry tie-infrom £495priced on survey, ex VAT
Timed locking and night mode set-upincluded with the aboveprogrammed at commissioning
Electric lock added to an automatic dooron surveydepends on the door and the lock type

Standards and rules in England

Under the Equality Act 2010, service providers and employers must make reasonable adjustments for disabled people, which can include altering a physical feature such as a heavy entrance door. Fitting an automatic door helps, but does not on its own guarantee those duties are met.

Whoever motorises a manual door, or builds an automatic door from separate parts, may take on the manufacturer’s legal duties for the finished door: a risk assessment, a technical file kept available for the authorities, a Declaration of Conformity, the conformity marking and instructions. You receive the Declaration of Conformity and the instructions at handover. In Great Britain a new or converted powered door must meet the Supply of Machinery (Safety) Regulations 2008 before it is first used, and can carry the UKCA or the CE marking.

How it works

  1. Describe what you need. Whether the job is access control for automatic doors for a busy entrance or for a single internal door, a brief description and some photos let us understand it and plan a survey visit in Gerrards Cross.
  2. Free visit to the site. An engineer working under our management assesses the opening, the existing door and frame, the floor and the electrical supply, and notes any access, consent or timing issues to plan around.
  3. Your fixed quotation. The quote is fixed for the work it describes and lists each item, including any removal, making good and electrical work. It also states the lead time, the payment stages and the warranty terms.
  4. Fitting and sign-off. Work goes ahead on dates agreed with you. Once fitted, the door is adjusted and its safety functions are tested and recorded with reference to BS EN 16005, and you are shown how to use it.

Ask for a fixed price on access control for an automatic door in Gerrards Cross. The quote covers the reader, lock, wiring, testing and handover records.

Access control for automatic doors in Gerrards Cross: questions

Can you service the door and access control in Gerrards Cross together?

We can service the door and test the link to the access control on each visit, leaving a written record. Visits are chargeable and priced in writing before anyone attends. If your security installer looks after the system, we can coordinate visits with them.

How much should I budget for access control for automatic doors in Gerrards Cross?

Our guide starts from £795 excluding VAT (per door), the same guide price we use across the UK. The free site survey in Gerrards Cross confirms the price as a fixed, itemised written quote, and the guide price tool gives you a range before anyone visits.

Do you work with our security installer in Gerrards Cross?

Yes. Where a security installer already looks after your access control, we usually handle the door, the lock and the link to the operator, and they handle the reader, controller and permissions. The quote sets out who does what so nothing falls between the two.

Will our door in Gerrards Cross still release when the fire alarm sounds?

On an escape route, yes. Locks are wired to release on the fire alarm signal and, where the fire strategy requires it, the door opens and holds open. We test this with your fire alarm contractor at handover and record the result.

What happens to the old door when a new one is fitted in Gerrards Cross?

If the work replaces an existing door, frame or operator, removal and disposal are listed in the quote. The old door comes out only when the new one is ready to go in, so the opening is not left empty for longer than necessary. Making good to the surrounding wall, floor or ceiling is included where the quote says so.

What does the free site survey in Gerrards Cross involve?

An engineer working under our management visits the building, measures the opening, checks the frame, floor, head height and power supply, and looks at how people use the entrance. The survey is free and carries no obligation. Afterwards you receive a fixed, itemised written quote for access control for automatic doors, with drawings where the door type needs them.

Which building regulations apply to a new automatic entrance in Gerrards Cross?

In England the guidance is Approved Document M (Volume 2) for access, Approved Document B for fire safety and escape routes, and Approved Document K for glazing and powered doors. A new entrance can count as building work, so building control should be involved before it is ordered.

Next step

Access control for automatic doors in Gerrards Cross

Send the address, a photo if you have one and what the door needs to do. New installations get a free site survey and a fixed written quote; repairs and servicing are priced in writing before we attend.