From shops and surgeries to schools, care homes and private houses, any building in the PA34 postcode district can be covered for access control for automatic doors. Specialist engineers working under our management carry out the work, and you deal with us as the contracting party from start to finish.
Independent businesses in Oban often have one entrance and cannot close for long. Work is usually scheduled early, late or on a quiet day, and where a door must be out of use for a period, we plan to keep the entrance usable or secure.
What to think about for access control for automatic doors in Oban
- Think about lost cards and leavers. A system that lets you remove a card centrally is easier to run than a shared keypad code on a busy site.
- Decide how the door should behave at each time of day before the survey. Opening hours, cleaning shifts, deliveries and weekend events all affect the schedule the door will follow.
- If you already have an access control system, find out who installed and maintains it. Linking an automatic door is simpler when your security installer is part of the plan.
- Residential blocks in Oban usually have a managing agent or housing provider who sets the rules for fobs, visitors and fire alarm behaviour. Involve them early.
- Schools in Oban often want a remote release at the office and a schedule for drop-off and pick-up times. Agree how the door behaves in a lockdown with your safeguarding lead.
Access control for automatic doors in Oban: guide prices
The site survey is free, including the measured drawing and a fixed, itemised written quote. Guide price: from £795 ex VAT.
| Item | Guide price | Notes |
|---|---|---|
| Card or fob reader tied into the door | £795 – £2,495 | per door, ex VAT |
| Intercom or door entry tie-in | from £495 | priced on survey, ex VAT |
| Timed locking and night mode set-up | included with the above | programmed at commissioning |
| Electric lock added to an automatic door | on survey | depends on the door and the lock type |
Standards and rules in Scotland
Scottish building standards guidance (the non-domestic Technical Handbook) expects an accessible entrance door to give a clear opening of at least 800 mm, says powered doors improve accessibility as long as they add no new hazard, and expects signage, sensors that hold the door open long enough, and guarding against collision or entrapment.
Whoever motorises a manual door, or builds an automatic door from separate parts, may take on the manufacturer’s legal duties for the finished door: a risk assessment, a technical file kept available for the authorities, a Declaration of Conformity, the conformity marking and instructions. You receive the Declaration of Conformity and the instructions at handover. In Great Britain a new or converted powered door must meet the Supply of Machinery (Safety) Regulations 2008 before it is first used, and can carry the UKCA or the CE marking.
How it works
- Tell us about the entrance. Send the address, a few photos and a rough size of the opening, and say how the door is used. That is enough for us to suggest options for access control for automatic doors and book a survey in Oban.
- Free site survey. A specialist engineer working under our management measures the opening, checks the frame, floor, head height and power, and talks through how people use the entrance. There is no charge and no obligation.
- Fixed written quote. You receive a fixed, itemised written quote with the specification, lead time, payment stages and warranty terms. The price does not change unless the scope does, and any change is agreed in writing first.
- Installation and handover. The door is fitted on the agreed dates, then set up, tested and documented with reference to BS EN 16005. You are shown the controls and the simple checks to make, and receive the handover paperwork.
Want your automatic door in Oban to open only for the right people? Start with a free site survey, with no obligation.
Access control for automatic doors in Oban: questions
Can you service the door and access control in Oban together?
We can service the door and test the link to the access control on each visit, leaving a written record. Visits are chargeable and priced in writing before anyone attends. If your security installer looks after the system, we can coordinate visits with them.
Can you give me a price for access control for automatic doors in Oban?
Our guide starts from £795 excluding VAT (per door), the same guide price we use across the UK. The free site survey in Oban confirms the price as a fixed, itemised written quote, and the guide price tool gives you a range before anyone visits.
Do you work with our security installer in Oban?
Yes. Where a security installer already looks after your access control, we usually handle the door, the lock and the link to the operator, and they handle the reader, controller and permissions. The quote sets out who does what so nothing falls between the two.
Can you add access control to our automatic door in Oban?
In most cases, yes. We check the operator's inputs, the lock options and the cable route at a free survey, then quote a fixed price. We can connect to your existing system or supply a standalone reader or keypad for the door.
What power supply is needed for access control for automatic doors in Oban?
Most powered doors need a fused spur close to the operator, and some activation and access control devices also need a low-voltage link. The survey checks what is already there. If a new supply is required, the quote says whether we arrange it or your own electrician does, so nothing is left unclear on the day.
What happens once the installation in Oban is finished?
The engineer tests every function, including the safety sensors and the behaviour on power loss, and sets the door up with reference to BS EN 16005. You are shown how to use the controls and which simple checks to make, and you receive the handover documents, including the test record and any conformity paperwork that applies to the work.
Who is responsible for automatic doors on escape routes in Oban?
The person responsible for fire safety under the Fire (Scotland) Act 2005 for those premises. Scottish guidance allows automatic doors on escape routes only where they fail safely to outward opening or have a monitored fail-safe system that opens them on power failure, sensor failure and fire alarm.